These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 413062)
1. Bacteriological contamination of dialyzers. Clinical, bacteriological and scanning electron-microscopic evaluation of different dialysate mixing systems. Jans H; Bretlau P; Nielsen B Nephron; 1978; 20(1):10-7. PubMed ID: 413062 [TBL] [Abstract][Full Text] [Related]
2. Pseudomonas septicemia due to deficient disinfectant mixing during reuse. Vanholder R; Vanhaecke E; Ringoir S Int J Artif Organs; 1992 Jan; 15(1):19-24. PubMed ID: 1551723 [TBL] [Abstract][Full Text] [Related]
3. Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin. Gordon SM; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Favero MS; Jarvis WR J Am Soc Nephrol; 1992 Mar; 2(9):1436-44. PubMed ID: 1627766 [TBL] [Abstract][Full Text] [Related]
4. A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin. Pegues DA; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Gordon SM; Favero MS; Jarvis WR J Am Soc Nephrol; 1992 Oct; 3(4):1002-7. PubMed ID: 1450362 [TBL] [Abstract][Full Text] [Related]
6. Pseudomonas aeruginosa bacteremia in a dialysis unit. 1. Recognition of cases, epidemiologic studies and attempts at control. Uman SJ; Johnson CE; Beirne GJ; Kunin CM Am J Med; 1977 May; 62(5):667-71. PubMed ID: 404878 [TBL] [Abstract][Full Text] [Related]
7. Functional and morphological changes in refused Gambro-Lundia Nova dialyzers. Teehan BP; Smith LJ; Hartigan MF; Griesemer GA; Gilgore GS; Sigler MH Proc Clin Dial Transplant Forum; 1975 Nov; 5():51-7. PubMed ID: 785463 [No Abstract] [Full Text] [Related]
8. [Dialysate and biocompatibility in hemodialysis]. Berland Y Nephrologie; 1998; 19(6):329-34. PubMed ID: 9836194 [TBL] [Abstract][Full Text] [Related]
9. Ultrafiltration using the polysulfone membrane to reduce the cytokine-inducing activity of contaminated dialysate. Lonnemann G; Schindler R Clin Nephrol; 1994 Jul; 42 Suppl 1():S37-43. PubMed ID: 7923982 [No Abstract] [Full Text] [Related]
10. Transfer of cytokine-inducing bacterial products across hemodialyzer membranes in the presence of plasma or whole blood. Pereira BJ; Sundaram S; Barrett TW; Butt NK; Porat R; King AJ; Dinarello CA Clin Nephrol; 1996 Dec; 46(6):394-401. PubMed ID: 8982556 [TBL] [Abstract][Full Text] [Related]
11. New polyether sulfone dialyzers attenuate passage of cytokine-inducing substances from pseudomonas aeruginosa contaminated dialysate. Jaber BL; Gonski JA; Cendoroglo M; Balakrishnan VS; Razeghi P; Dinarello CA; Pereira BJ Blood Purif; 1998; 16(4):210-9. PubMed ID: 9736790 [TBL] [Abstract][Full Text] [Related]
12. Factors that influence microbial contamination of fluids associated with hemodialysis machines. Favero MS; Carson LA; Bond WW; Petersen NJ Appl Microbiol; 1974 Nov; 28(5):822-30. PubMed ID: 4216291 [TBL] [Abstract][Full Text] [Related]
13. Easy production of sterile, pyrogen-free dialysate. Erley CM; von Herrath D; Hartenstein-Koch K; Kutschera D; Amir-Moazami B; Schaefer K ASAIO Trans; 1988; 34(3):205-7. PubMed ID: 3196509 [TBL] [Abstract][Full Text] [Related]
14. Bacterial contamination of the blood compartment originating from the dialysate in haemodialysers. Kolmos HJ J Hosp Infect; 1984 Mar; 5(1):70-5. PubMed ID: 6202751 [TBL] [Abstract][Full Text] [Related]
15. Short bacterial DNA fragments: detection in dialysate and induction of cytokines. Schindler R; Beck W; Deppisch R; Aussieker M; Wilde A; Göhl H; Frei U J Am Soc Nephrol; 2004 Dec; 15(12):3207-14. PubMed ID: 15579524 [TBL] [Abstract][Full Text] [Related]
17. When good water goes bad: how it happens, clinical consequences and possible solutions. Lonnemann G Blood Purif; 2004; 22(1):124-9. PubMed ID: 14732820 [TBL] [Abstract][Full Text] [Related]
18. Endotoxemia in febrile reactions during hemodialysis. Raij L; Shapiro FL; Michael AF Kidney Int; 1973 Jul; 4(1):57-60. PubMed ID: 4198891 [No Abstract] [Full Text] [Related]
19. The bacteriological quality of hemodialysis solution as related to several environmental factors. Lauer J; Streifel A; Kjellstrand C; DeRoos R Nephron; 1975; 15(2):87-97. PubMed ID: 807862 [TBL] [Abstract][Full Text] [Related]
20. [Hypersensitivity reactions during hemodialysis. Role of high permeability, retrofiltration and bacterial contamination of the dialysate]. Montagnac R; Schillinger F; Milcent T; Croix JC Nephrologie; 1988; 9(1):29-32. PubMed ID: 3134622 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]