These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 4153392)

  • 1. Letter: Interference from serum separators in gas-chromatographic drug analysis.
    Deome AJ
    Clin Chem; 1974 Oct; 20(10):1383. PubMed ID: 4153392
    [No Abstract]   [Full Text] [Related]  

  • 2. Letter: Interference from serum separators in drug screening by gas chromatography.
    Brown HH; Vanko M; Meola JM
    Clin Chem; 1974 Jul; 20(7):919. PubMed ID: 4152010
    [No Abstract]   [Full Text] [Related]  

  • 3. Analysis of blood. A simplified gas chromatographic approach for toxicologic purposes.
    Thompson HL; Decker WJ
    Am J Clin Pathol; 1968 Jan; 49(1):103-7. PubMed ID: 4383911
    [No Abstract]   [Full Text] [Related]  

  • 4. Alkylation with alkylhalides as a derivatization method for the gas chromatographic determination of acidic pharmaceuticals.
    Hulshoff A; Förch AD
    J Chromatogr; 1981 Dec; 220(3):275-311. PubMed ID: 7035475
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interference from serum separators in total protein determination by refractometry.
    Collins G; Rose ME; Carter P
    Clin Chim Acta; 1975 Feb; 59(1):105-6. PubMed ID: 1122645
    [No Abstract]   [Full Text] [Related]  

  • 6. Effects of contaminants in blood-collection devices on measurements of therapeutic drugs.
    Ji SQ; Evenson MA
    Clin Chem; 1983 Mar; 29(3):456-61. PubMed ID: 6825254
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Drug assay interference caused by plasticizer in Vacutainers.
    Shah VP; Knapp G; Skelly JP; Cabana BE
    Am J Hosp Pharm; 1982 Sep; 39(9):1454. PubMed ID: 7137177
    [No Abstract]   [Full Text] [Related]  

  • 8. Gas chromatographic determination of drug levels for the evaluation of a combined hemoperfusion-hemodialysis treatment.
    De Waele M; Heyndrickx A; De Broe M
    J Anal Toxicol; 1982; 6(6):282-5. PubMed ID: 7162136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interference with measurements of certain drugs in plasma by a plasticizer in vacutainer tubes.
    Shah VP; Knapp G; Skelly JP; Cabana BE
    Clin Chem; 1982 Nov; 28(11):2327-8. PubMed ID: 7127786
    [No Abstract]   [Full Text] [Related]  

  • 10. Gas chromatographic screening for drugs and metabolites in plasma and urine.
    Jarvie DR; Simpson D
    Ann Clin Biochem; 1984 Mar; 21 ( Pt 2)():92-101. PubMed ID: 6143530
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Elevated temperature reversed-phase paper chromatography of derivatives of selected drugs.
    Street HV
    J Chromatogr; 1970 Apr; 48(2):238-40. PubMed ID: 5445425
    [No Abstract]   [Full Text] [Related]  

  • 12. Interference in plasma level measurements of certain drugs due to a plasticizer in Vacutainers.
    Shah VP; Knapp G; Skelly JP; Cabana BE
    J Pharm Sci; 1982 Oct; 71(10):II. PubMed ID: 7143202
    [No Abstract]   [Full Text] [Related]  

  • 13. Methods of therapeutic drug analysis.
    Hill RE
    Clin Biochem; 1986 Apr; 19(2):113-21. PubMed ID: 3708793
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gas chromatographic determination of drugs in post-mortem blood.
    Alha A; Korte T
    Ann Med Exp Biol Fenn; 1972; 50(4):175-9. PubMed ID: 4664258
    [No Abstract]   [Full Text] [Related]  

  • 15. Blood-collection tubes evaluated for use in measurement of some therapeutic drugs.
    Pou Clave L; Garcia Beltran L; Peremiquel Lluch M; Pascual Mostaza C; Schwartz Riera S
    Clin Chem; 1988 Apr; 34(4):795. PubMed ID: 3359634
    [No Abstract]   [Full Text] [Related]  

  • 16. A rapid micro-method for the screening and measurement of barbiturates and related compounds in plasma by gas-liquid chromatography.
    Flanagan RJ; Withers G
    J Clin Pathol; 1972 Oct; 25(10):899-904. PubMed ID: 4646303
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Isolation of drugs from blood with macroreticular resins (author's transl)].
    Machata G; Vycudilik W
    Arch Toxicol; 1975 Feb; 33(2):115-22. PubMed ID: 1242296
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gas-liquid chromatography in pharmacology and toxicology. Pharmacokinetic analysis limited by the sensitivity of the analytical technique.
    Vree TB; van Rossum JM; Breimer DD; van Ginneken GA; van Kordelaar JM
    Clin Chim Acta; 1971 Sep; 34(2):311-9. PubMed ID: 5113568
    [No Abstract]   [Full Text] [Related]  

  • 19. [A simple gas chromatographic method for the determination of hypnotics in the serum (author's transl)].
    Külpmann WR
    J Clin Chem Clin Biochem; 1979 Mar; 17(3):115-21. PubMed ID: 35581
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Problems with the infusion application technic in intensive care].
    Brost F; Halmàgyi M; Sporn P; Steinbereithner K
    Klin Anasthesiol Intensivther; 1977; (14):181-9. PubMed ID: 412007
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.