122 related articles for article (PubMed ID: 415385)
1. [Contribution to deep electron pendulous therapy. VIII. Communication: concerning the problem of diverging contours in telecentric electron pendulous irradiation using the electron energies 10 MeV and 20 MeV (author's transl)].
Krause K; Hüdepohl G; Fees H; Rassow J
Strahlentherapie; 1978 Jan; 154(1):29-37. PubMed ID: 415385
[TBL] [Abstract][Full Text] [Related]
2. [Depth therapy with electrons in the thoracic region. V. Dosimetric studies with telecentric small-angle pendulous irradiation (author's transl)].
Gürtler KF; Darai S; Schnabel K; Kuttig H
Strahlentherapie; 1977 Mar; 153(3):143-8. PubMed ID: 841604
[TBL] [Abstract][Full Text] [Related]
3. Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy.
Chen Z; Agostinelli AG; Wilson LD; Nath R
Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):872-85. PubMed ID: 15183491
[TBL] [Abstract][Full Text] [Related]
4. [Load to the lung and spinal cord in the treatment of exophageal carcinoma using telecentric-excentric pendulous 42 MeV betatron irradiation].
Koischwitz D; Frommhold H; Winken R
Strahlentherapie; 1976 Feb; 151(2):183-91. PubMed ID: 816040
[TBL] [Abstract][Full Text] [Related]
5. [Deep electron therapy using pendulum irradiation. VII. Dosimetry and example for application of telecentric pendulum irradiation with electrons of 5-10 MeV (shell irradiation) under changing focus-skin distance].
Hüdepohl G; Rassow J
Strahlentherapie; 1973 Nov; 146(5):546-58. PubMed ID: 4206756
[No Abstract] [Full Text] [Related]
6. [Optimation of the dose geometry during irradiation of the para-aortic lymph nodes with 42 MeV photons (author's transl)].
Koischwitz D; Frommhold H; Winken R
Strahlentherapie; 1977 Feb; 153(2):69-81. PubMed ID: 402713
[TBL] [Abstract][Full Text] [Related]
7. [An analytical method for calculation of electron dose distributions. Part II: Experimental verification and application in coplanar irradiation techniques (author's transl)].
Kimmig B; Fehrentz D; Ihnen E; Marzinko H
Strahlentherapie; 1979 May; 155(5):316-27. PubMed ID: 108816
[TBL] [Abstract][Full Text] [Related]
8. [Consideration of inhomogeneities in irradiation planning. 3. Influence of inhomogeneities on the shape of the depth dose curve in water with electronic radiation of different energies (author's transl)].
Zwicker H; Felix R
Strahlentherapie; 1977 Feb; 153(2):86-94. PubMed ID: 402714
[TBL] [Abstract][Full Text] [Related]
9. [Electron therapy using wedge filters. I. Experimental studies using wedge filters made from polystyrol].
Kuttig H; Ziegler F
Strahlentherapie; 1975 Oct; 150(4):383-8. PubMed ID: 810927
[TBL] [Abstract][Full Text] [Related]
10. [A simple formula for determination of the mean electron energy in a body irradiated by fast electrons (author's transl)].
Markus B
Strahlentherapie; 1978 Jun; 154(6):388-93. PubMed ID: 96551
[TBL] [Abstract][Full Text] [Related]
11. [Changes of the depth dose curve in case of 42 MeV photon irradiation through a plexiglass plate of 3 cm (author's transl)].
Ihnen E
Strahlentherapie; 1978 Jul; 154(7):479-81. PubMed ID: 97805
[TBL] [Abstract][Full Text] [Related]
12. [Breakdown of the energy of a fixed 7 MeV electron bundle in the treatment of mycosis fungoides (author's transl)].
Marinello G; Buscaill A; Baillet F
J Radiol Electrol Med Nucl; 1977 Nov; 58(11):693-9. PubMed ID: 412961
[TBL] [Abstract][Full Text] [Related]
13. [An analytical method to calculate electron dose distributions. Part I: Method (author's transl)].
Fehrentz D; Kimmig B; Ihnen E; Schröder-Babo P
Strahlentherapie; 1979 Apr; 155(4):248-53. PubMed ID: 452050
[TBL] [Abstract][Full Text] [Related]
14. [Influence of cavities on dose distribution in electron depth therapy].
Fehrentz D; Krone H; Schröder-Babo P
Strahlentherapie; 1975 Mar; 149(3):276-95. PubMed ID: 806994
[TBL] [Abstract][Full Text] [Related]
15. [The role of large portal- and shielding-techniques in radiotherapy (author's transl)].
Schmitt G; Holfeld H; Bamberg M
Rontgenblatter; 1978 Mar; 31(3):168-72. PubMed ID: 417394
[TBL] [Abstract][Full Text] [Related]
16. [Dose distributions of fast electrons with an energy of 7-24 Mev in electromagnetic beam formation].
Shambulov RS; Khvan GV; Saĭbekov TS; Azhigaliev NA; Shuinbekov AD
Med Radiol (Mosk); 1983 Mar; 28(3):14-8. PubMed ID: 6403798
[TBL] [Abstract][Full Text] [Related]
17. [Characterization of a diode system for in vivo dosimetry with electron beams].
Ragona R; Rossetti V; Lucio F; Anglesio S; Giglioli FR
Radiol Med; 2001 Oct; 102(4):271-5. PubMed ID: 11740457
[TBL] [Abstract][Full Text] [Related]
18. Dual scattering foil design for poly-energetic electron beams.
Kainz KK; Antolak JA; Almond PR; Bloch CD; Hogstrom KR
Phys Med Biol; 2005 Mar; 50(5):755-67. PubMed ID: 15798252
[TBL] [Abstract][Full Text] [Related]
19. [Calculation of the dose distribution of high-energy electrons within and behind tissue inhomogeneities of any width. II. Influence of multiple scattering (author's transl)].
Mandour MA; Harder D
Strahlentherapie; 1978 Aug; 154(8):546-53. PubMed ID: 98866
[TBL] [Abstract][Full Text] [Related]
20. Use of the computer in high-energy electron therapy.
Poretti GG; Ionesco-Farca F
Radiol Clin (Basel); 1978; 47(2):139-53. PubMed ID: 625554
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]