These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 415394)

  • 1. Hemolytic anti-hr" (e) detectable solely by an automated polybrene technique.
    Snyder EL; Spivack M; Novodoff D; Kling G
    Transfusion; 1978; 18(1):79-83. PubMed ID: 415394
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemolytic transfusion reaction due to Rh antibodies detectable only by manual polybrene and polyethylene glycol technique.
    Lin CK; Wong KF; Mak KH; Yuen CM; Lee AW
    Am J Clin Pathol; 1995 Dec; 104(6):660-2. PubMed ID: 8526209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anti-Jka, -C, and -E in a single patient, initially demonstrable only by the manual hexadimethrine bromide (Polybrene) test, with incompatibilities confirmed by 51Cr-labeled red cell studies.
    Maynard BA; Smith DS; Farrar RP; Kraetsch RE; Chaplin H
    Transfusion; 1988; 28(4):302-6. PubMed ID: 3133842
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Detection of irregular alloantibodies by Groupamatic using a trypsin-polybrene-citrate technic].
    Confida S; Hurel C; Muller A; Garretta M
    Rev Fr Transfus Immunohematol; 1978 Mar; 21(2):457-72. PubMed ID: 97758
    [No Abstract]   [Full Text] [Related]  

  • 5. Comparison of a modified manual hexadimethrine bromide (Polybrene) and a low-ionic-strength solution antibody detection technique.
    Ferrer Z; Wright J; Moore BP; Freedman J
    Transfusion; 1985; 25(2):145-8. PubMed ID: 3984009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of a manual hexadimethrine bromide-antiglobulin test with saline- and albumin-antiglobulin tests for pretransfusion testing.
    Mintz PD; Anderson G
    Transfusion; 1987; 27(2):134-7. PubMed ID: 3824470
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a commercial hexadimethrine bromide method and low-ionic-strength solution for antibody detection with special reference to anti-K.
    Letendre PL; Williams MA; Ferguson DJ
    Transfusion; 1987; 27(2):138-41. PubMed ID: 3103267
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The manual Polybrene test has limited sensitivities for detecting the Kidd blood group system.
    Liu JC; Wang Y; Liu FP; He YS
    Scand J Clin Lab Invest; 2009; 69(7):797-800. PubMed ID: 19929723
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Possible insensitivity of the polybrene antibody screen to detect anti-Jka.
    Liu F; Liu J
    Ann Clin Lab Sci; 2006; 36(1):101-2. PubMed ID: 16501244
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A proposal for compatibility testing incorporating the manual hexadimethrine bromide (Polybrene) test.
    Steane EA; Steane SM; Montgomery SR; Pearson JR
    Transfusion; 1985; 25(6):540-4. PubMed ID: 4071598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated screening of antenatal samples using a low ionic strength polybrene system.
    Powell SB; Howell P; Renton PH
    Clin Lab Haematol; 1981; 3(4):343-50. PubMed ID: 6800682
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The manual polybrene test: a simple and rapid procedure for detection of red cell antibodies.
    Lalezari P; Jiang AF
    Transfusion; 1980; 20(2):206-11. PubMed ID: 6768173
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transfusion reaction. An immunologic hazard of blood transfusion.
    Pineda AA; Taswell HF; Brzica SM
    Transfusion; 1978; 18(1):1-7. PubMed ID: 415392
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Delayed hemolytic transfusion reactions. An often-missed entity.
    Solanki D; McCurdy PR
    JAMA; 1978 Feb; 239(8):729-31. PubMed ID: 621892
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical significance of RBC alloantibodies and autoantibodies in sickle cell patients who received transfusions.
    Aygun B; Padmanabhan S; Paley C; Chandrasekaran V
    Transfusion; 2002 Jan; 42(1):37-43. PubMed ID: 11896310
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Red cell phenotyping using hexadimethrine bromide (Polybrene) in a microplate system.
    Anderson HJ; Patel S
    Transfusion; 1984; 24(4):353-6. PubMed ID: 6464161
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Limitations of Polybrene to detect ABO incompatibility.
    Mintz PD; Anderson G
    Vox Sang; 1986; 51(4):318-20. PubMed ID: 3798865
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accelerated immune red cell destruction in the absence of serologically detectable alloantibodies.
    Davey RJ; Gustafson M; Holland PV
    Transfusion; 1980; 20(3):348-53. PubMed ID: 6770508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Automated screening and identification of irregular anti-erythrocyte antibodies].
    Wattar B; Govaerts A
    Rev Fr Transfus Immunohematol; 1982 Jun; 25(3):297-308. PubMed ID: 6810440
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Manual polybrene test versus saline test as a means of detecting alloantibodies against red cells in the pretransfusion examination].
    de Chirinos SM; Lichtiger B
    Sangre (Barc); 1991 Feb; 36(1):43-6. PubMed ID: 1853273
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.