BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 4198572)

  • 1. [Aortic insufficiency on a Starr's valve].
    Acar J; Raimbaux J; Lainée R; Antebi L; Grimberg D; Luxereau P
    Arch Mal Coeur Vaiss; 1973 Jan; 66(1):113-21. PubMed ID: 4198572
    [No Abstract]   [Full Text] [Related]  

  • 2. [Remote prognosis of mitral and aortic Starr's valve].
    Penther P; Bensaid J; Sozutek Y; Maurice P; Lenègre J
    Arch Mal Coeur Vaiss; 1969 May; 62(5):679-99. PubMed ID: 4253907
    [No Abstract]   [Full Text] [Related]  

  • 3. [Massive aortic insufficiency consecutive to an incomplete rupture of the suprasigmoidian aorta. Insertion of a Starr's valve].
    Di Matteo J; Vacheron A; Neveux JY; Heulin A; Glaudon G; Delvaux JC
    Arch Mal Coeur Vaiss; 1974 Aug; 67(8):981-5. PubMed ID: 4217142
    [No Abstract]   [Full Text] [Related]  

  • 4. Cocking of a poppet-disc prosthesis in the aortic position. A cause of intermittent aortic regurgitation.
    Hammer WJ; Hearne MJ; Roberts WC
    J Thorac Cardiovasc Surg; 1976 Feb; 71(2):259-61. PubMed ID: 1246152
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Structural valve failure with every beat regurgitation observed using the Medtronic Advantage aortic valve.
    Hansen L; Danne M; Hoffmann B; Riess FC
    J Thorac Cardiovasc Surg; 2007 Nov; 134(5):1344-5. PubMed ID: 17976473
    [No Abstract]   [Full Text] [Related]  

  • 6. Sticking aortic valve. A complication of fabric-covered ball-valve prosthesis.
    Mullin MJ; Muth WF; McNamara JJ
    J Thorac Cardiovasc Surg; 1972 Feb; 63(2):215-7. PubMed ID: 5009732
    [No Abstract]   [Full Text] [Related]  

  • 7. [Bacterial endocarditis on aortic valvular prosthesis. A four cases report (author's transl)].
    Vanetti A; Donzeau-Gouge GP; Benomar M; Gaillard D; Perroud A; Daumet P
    Ann Chir; 1981; 35(3):172-3. PubMed ID: 7235587
    [No Abstract]   [Full Text] [Related]  

  • 8. Valve replacement for aortic regurgitation: factors influencing results.
    Friedlich AL; Curfman GD; Bland EF; Buckley MJ; Mundth ED; Austen WG
    Trans Am Clin Climatol Assoc; 1976; 87():59-68. PubMed ID: 960425
    [No Abstract]   [Full Text] [Related]  

  • 9. [Long-term observations following artificial aortic and mitral valve replacement with special reference to valve insufficiency, thromboembolism, endocarditis and ball changes].
    Brand E; Rudolph W; Dietze G; Wicklmayr M; Klinner W
    Verh Dtsch Ges Inn Med; 1968; 74():1006-12. PubMed ID: 5714223
    [No Abstract]   [Full Text] [Related]  

  • 10. [Aortic regurgitation due to aortic valve prolapse].
    Shigenobu M; Aoki A; Kudo Y; Ohsumi S; Shichijo K; Senoo Y; Teramoto S
    Kyobu Geka; 1987 Jun; 40(7):534-8. PubMed ID: 3626218
    [No Abstract]   [Full Text] [Related]  

  • 11. [Follow-up results 5 years after aortic valve replacement with a Smeloff-Cutter prosthesis. Apropos of 200 cases].
    Soyer R; Brunet A; Redonnet M; Hubscher C; Letac B
    Arch Mal Coeur Vaiss; 1983 Apr; 76(4):391-9. PubMed ID: 6223609
    [No Abstract]   [Full Text] [Related]  

  • 12. [Triple valve replacements. Immediate risks and long-term prognosis].
    Gautier C; Cabrol A; Guiraudon G; Luciani J; Mattei MF; Leon L; Chapelle M
    Arch Mal Coeur Vaiss; 1973 Dec; 66(12):1473-8. PubMed ID: 4210419
    [No Abstract]   [Full Text] [Related]  

  • 13. Poppet embolization in cloth-covered Silastic poppet valves.
    Pluth JR; Danielson GK
    Mayo Clin Proc; 1974 Nov; 49(11):811-4. PubMed ID: 4420364
    [No Abstract]   [Full Text] [Related]  

  • 14. Acute aortic insufficiency.
    Hanna K; Antakli T; Savcendo M; Talley JD
    J Ark Med Soc; 1998 Jun; 95(1):48-9. PubMed ID: 9640902
    [No Abstract]   [Full Text] [Related]  

  • 15. ["Ball disease" of Starr's aortic valves].
    Louis P; Duzer A; Faure D; Bouhey J
    Coeur Med Interne; 1970 Jul; 9(3):263-80. PubMed ID: 5450464
    [No Abstract]   [Full Text] [Related]  

  • 16. Tilting-disc versus bileaflet mechanical prostheses in the aortic position: a multicenter evaluation.
    Vitale N; De Feo M; De Siena P; Cappabianca G; Onorati F; Gregorio R; Branzoli S; de Luca L; Schinosa T; Viganò M; Scardone M; Cotrufo M
    J Heart Valve Dis; 2004 May; 13 Suppl 1():S27-34. PubMed ID: 15224997
    [No Abstract]   [Full Text] [Related]  

  • 17. [Management of valve detachment following aortic valve replacement in aortic regurgitation due to aortitis].
    Kawazoe K; Fujita T; Ohmori F
    Rinsho Kyobu Geka; 1984 May; 4(3):372-5. PubMed ID: 6474061
    [No Abstract]   [Full Text] [Related]  

  • 18. [Recurrent ejection of aortic valve prostheses. Apropos of 22 case reports].
    Bensaid J; Gandjbakhch I; Dewilde J; Bassand JP; Pornin M; Ourbak P; Pony JC; Logeais Y; Acar J; Gerbaux A; Cabrol C; Maurice P
    Arch Mal Coeur Vaiss; 1983 Feb; 76(2):123-31. PubMed ID: 6407420
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [A rare complication of St. Jude Medical valve in aortic position. Suggestion of the valve orientation].
    Takeuchi Y; Suma K; Inoue K; Shiroma K; Koyama Y; Narumi J; Nishiyama S; Kaneko H; Nakata M
    Kyobu Geka; 1984 Jul; 37(7):514-9. PubMed ID: 6482097
    [No Abstract]   [Full Text] [Related]  

  • 20. Experience with the Wada-Cutter valve prosthesis in the aortic area. One-year follow-up.
    Björk VO
    J Thorac Cardiovasc Surg; 1970 Jul; 60(1):26-33. PubMed ID: 4912965
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.