These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 4213649)

  • 21. Oligoclonal bands and the IgG index in multiple sclerosis: uses and limitations.
    Giles PD; Heath JP; Wroe SJ
    Ann Clin Biochem; 1989 Jul; 26 ( Pt 4)():1317-23. PubMed ID: 2764482
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cerebrospinal fluid immunoglobulin G in childhood. Measurement by electroimmunodiffusion.
    Nellhaus G
    Arch Neurol; 1971 May; 24(5):441-8. PubMed ID: 4995260
    [No Abstract]   [Full Text] [Related]  

  • 23. Rapid immunoturbidimetric assay of albumin and immunoglobulin G in serum and cerebrospinal fluid with an automatic discrete analyser.
    Kamp HH; Luderer TK; Muller HJ; Sopjes-Kruk A
    Clin Chim Acta; 1981 Aug; 114(2-3):195-205. PubMed ID: 6793271
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison between chemical analysis and magnetic resonance imaging with the clinical diagnosis of multiple sclerosis.
    Papadopoulos NM; McFarlin DE; Patronas NJ; McFarland HF; Costello R
    Am J Clin Pathol; 1987 Sep; 88(3):365-8. PubMed ID: 3630976
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Bivariate evaluation of laboratory findings: immunoglobulin G and albumin in cerebrospinal fluid (author's transl)].
    Bernhardt W; Weisner B
    J Clin Chem Clin Biochem; 1976 Sep; 14(9):443-7. PubMed ID: 965900
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Electroimmunodiffusion: a simple, rapid, reliable, and valid method for the simultaneous determination of cerebrospinal fluid and serum immunoglobulin-G and albumin.
    Tourtellotte WW; Tavolato BA; Parker JA; Walker JE; Comiso PC
    Trans Am Neurol Assoc; 1970; 95():323-5. PubMed ID: 4998768
    [No Abstract]   [Full Text] [Related]  

  • 27. Diagnostic usefulness of cerebrospinal fluid in multiple sclerosis.
    Mehta PD
    Crit Rev Clin Lab Sci; 1991; 28(3):233-51. PubMed ID: 1905549
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Quantitation of human immunoglobulin G and albumin in electroimmunodiffusion gels containing ionic and nonionic detergents.
    Shapshak P; Tourtellotte WW; Staugaitis S; Cowan T; Ingram T; Weil ML; Bliss D; Tourtellotte WG
    Anal Biochem; 1983 Jul; 132(2):305-11. PubMed ID: 6414332
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Local cerebrospinal fluid IgG production in multiple sclerosis].
    Schipper H
    Schriftenr Neurol; 1989; 30():1-91. PubMed ID: 2678429
    [No Abstract]   [Full Text] [Related]  

  • 30. The use and abuse of the cerebrospinal fluid IgG profile in the adult: a practical evaluation.
    Hershey LA; Trotter JL
    Ann Neurol; 1980 Oct; 8(4):426-34. PubMed ID: 6776879
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Double ring formation in single radial immunodiffusion for kappa chains in multiple sclerosis cerebrospinal fluid.
    Iwashita H; Grunwald F; Bauer H
    J Neurol; 1974; 207(1):45-52. PubMed ID: 4142885
    [No Abstract]   [Full Text] [Related]  

  • 32. Quantitation of IgG, IgA and IgM in the CSF by radioimmunoassay.
    Mingioli ES; Strober W; Tourtellotte WW; Whitaker JN; McFarlin DE
    Neurology; 1978 Oct; 28(10):991-5. PubMed ID: 106329
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Thyroglobulin determined in thyroid fine needle aspiration biopsies by radial immunodiffusion and electroimmunodiffusion.
    Salabè GB; Corvo L; Lotz H
    Eur J Clin Chem Clin Biochem; 1996 Jan; 34(1):43-7. PubMed ID: 8704034
    [TBL] [Abstract][Full Text] [Related]  

  • 34. CSF characteristics in early-onset multiple sclerosis.
    Pohl D; Rostasy K; Reiber H; Hanefeld F
    Neurology; 2004 Nov; 63(10):1966-7. PubMed ID: 15557527
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cerebrospinal fluid proteins and serum immunoglobulins. Occurrence in multiple sclerosis and other neurological diseases: comparative measurement of gamma-globulin and the IgG class.
    Fischer-Williams M; Roberts RC
    Arch Neurol; 1971 Dec; 25(6):526-34. PubMed ID: 4107216
    [No Abstract]   [Full Text] [Related]  

  • 36. Radial immunodiffusion of spinal fluid: diagnostic value in multiple sclerosis.
    Berner JJ; Ciemins VA; Schroeder EF
    Am J Clin Pathol; 1972 Aug; 58(2):145-52. PubMed ID: 4625860
    [No Abstract]   [Full Text] [Related]  

  • 37. Evaluation of multiple sclerosis patients by cerebrospinal fluid.
    Kaleemullah AJ; O'Kell RT
    Mo Med; 1976 Sep; 73(9):520-2. PubMed ID: 967141
    [No Abstract]   [Full Text] [Related]  

  • 38. [Simultaneous determination of immunoglobulin G and albumin in ventricular fluid and serum (author's transl)].
    Weisner B
    Nervenarzt; 1977 Dec; 48(12):684-7. PubMed ID: 414145
    [No Abstract]   [Full Text] [Related]  

  • 39. Immunoglobulin abnormalities in multiple sclerosis. Relation to clinical parameters: exacerbations and remissions.
    Olsson JE; Link H
    Arch Neurol; 1973 Jun; 28(6):392-9. PubMed ID: 4121785
    [No Abstract]   [Full Text] [Related]  

  • 40. The cerebrospinal fluid immunoglobulin G index as a diagnostic aid in multiple sclerosis: a Bayesian approach.
    Hische EA; van der Helm HJ; van Walbeek HK
    Clin Chem; 1982 Feb; 28(2):354-5. PubMed ID: 7055958
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.