These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 4216291)

  • 1. Factors that influence microbial contamination of fluids associated with hemodialysis machines.
    Favero MS; Carson LA; Bond WW; Petersen NJ
    Appl Microbiol; 1974 Nov; 28(5):822-30. PubMed ID: 4216291
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Editorial: Microbial contamination of water used for hemodialysis.
    Blagg CR; Tenckhoff H
    Nephron; 1975; 15(2):81-6. PubMed ID: 807861
    [No Abstract]   [Full Text] [Related]  

  • 3. The bacteriological quality of hemodialysis solution as related to several environmental factors.
    Lauer J; Streifel A; Kjellstrand C; DeRoos R
    Nephron; 1975; 15(2):87-97. PubMed ID: 807862
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microbial contamination of dialysate and its prevention in haemodialysis units.
    Oie S; Kamiya A; Yoneda I; Uchiyama K; Tsuchida M; Takai K; Naito K
    J Hosp Infect; 2003 Jun; 54(2):115-9. PubMed ID: 12818584
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bacteriological contamination of dialyzers. Clinical, bacteriological and scanning electron-microscopic evaluation of different dialysate mixing systems.
    Jans H; Bretlau P; Nielsen B
    Nephron; 1978; 20(1):10-7. PubMed ID: 413062
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Guidelines on water and solutions for dialysis. Italian Society of Nephrology].
    Alloatti S; Bolasco P; Canavese C; Cappelli G; Pedrini L; Pizzarelli F; Pontoriero G; Santoro A; Anastasio P; Teatini U; Fuiano G;
    G Ital Nefrol; 2005; 22(3):246-73. PubMed ID: 16001369
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemodialyzer Reuse and Gram-Negative Bloodstream Infections.
    Edens C; Wong J; Lyman M; Rizzo K; Nguyen D; Blain M; Horwich-Scholefield S; Moulton-Meissner H; Epson E; Rosenberg J; Patel PR
    Am J Kidney Dis; 2017 Jun; 69(6):726-733. PubMed ID: 27940061
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pseudomonas aeruginosa bacteremia in a dialysis unit. 1. Recognition of cases, epidemiologic studies and attempts at control.
    Uman SJ; Johnson CE; Beirne GJ; Kunin CM
    Am J Med; 1977 May; 62(5):667-71. PubMed ID: 404878
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative microbiological monitoring of hemodialysis fluids: evaluation of methods and demonstration of lack of test relevance in single-pass hemodialysis machines with automatic dialysate proportioning with reverse osmosis-treated tap water.
    Doern GV; Brogden BE; DiFederico JD; Earls JE; Quinn ML
    J Clin Microbiol; 1982 Dec; 16(6):1025-9. PubMed ID: 6761356
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microbial and endotoxin contamination in water and dialysate in the central United States.
    Klein E; Pass T; Harding GB; Wright R; Million C
    Artif Organs; 1990 Apr; 14(2):85-94. PubMed ID: 2350260
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prevent infection linked to the dialysis water in a hemodialysis center in Fez city (Morocco).
    Oumokhtar B; Lalami Ael O; Mahmoud M; Berrada S; Arrayhani M; Houssaini TS
    Pan Afr Med J; 2013; 16():122. PubMed ID: 24839530
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Contamination by disinfection byproducts (DPBs) and microbiological quality of dialysis water: a study in an Italian hospital dialysis service].
    Viti A; Tinti P; Verrucoli G; Lorini C; Sacco C; Lanciotti E
    Ig Sanita Pubbl; 2006; 62(2):173-87. PubMed ID: 17206188
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monitoring the microbiological quality of dialysate and treated water.
    Asserraji M; Maoujoud A; Belarbi M; Elfarouki R
    Saudi J Kidney Dis Transpl; 2014 Jan; 25(1):91-5. PubMed ID: 24434388
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evidence of bacterial biofilm in tubing from hydraulic pathway of hemodialysis system.
    Man NK; Degremont A; Darbord JC; Collet M; Vaillant P
    Artif Organs; 1998 Jul; 22(7):596-600. PubMed ID: 9684698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New polyether sulfone dialyzers attenuate passage of cytokine-inducing substances from pseudomonas aeruginosa contaminated dialysate.
    Jaber BL; Gonski JA; Cendoroglo M; Balakrishnan VS; Razeghi P; Dinarello CA; Pereira BJ
    Blood Purif; 1998; 16(4):210-9. PubMed ID: 9736790
    [TBL] [Abstract][Full Text] [Related]  

  • 16. National Kidney Foundation report on dialyzer reuse. Task Force on Reuse of Dialyzers, Council on Dialysis, National Kidney Foundation.
    Am J Kidney Dis; 1997 Dec; 30(6):859-71. PubMed ID: 9398135
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dialysis hypoxemia. Role of dialyzer membrane and dialysate delivery system.
    Vaziri ND; Wilson A; Mukai D; Darwish R; Rutz A; Hyatt J; Moreno C
    Am J Med; 1984 Nov; 77(5):828-33. PubMed ID: 6496536
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk assessment of opportunistic bacterial pathogens in drinking water.
    Rusin PA; Rose JB; Haas CN; Gerba CP
    Rev Environ Contam Toxicol; 1997; 152():57-83. PubMed ID: 9297985
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Classification and isolation frequency of glucose non-fermenting gram-negative rods from clinical sources].
    Takeda H; Murata K
    Rinsho Byori; 1972 Jul; 20(7):498-504. PubMed ID: 4631148
    [No Abstract]   [Full Text] [Related]  

  • 20. An outbreak of gram-negative bacteremia traced to contaminated O-rings in reprocessed dialyzers.
    Flaherty JP; Garcia-Houchins S; Chudy R; Arnow PM
    Ann Intern Med; 1993 Dec; 119(11):1072-8. PubMed ID: 8239225
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.