79 related articles for article (PubMed ID: 422381)
1. Shielding calculations below 100kVp in concrete-equivalent materials.
Christensen RC
Health Phys; 1979 Jan; 36(1):69-70. PubMed ID: 422381
[No Abstract] [Full Text] [Related]
2. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
Jaradat AK; Biggs PJ
Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
[TBL] [Abstract][Full Text] [Related]
3. Attenuation of primary and scatter radiation in concrete and steel for 18 MV X-rays from a Clinac-20 linear accelerator.
Abrath FG; Bello J; Purdy JA
Health Phys; 1983 Nov; 45(5):969-73. PubMed ID: 6417056
[TBL] [Abstract][Full Text] [Related]
4. [Shielding of the geomagnetic field in apartment houses].
Chernykh AM; Boriseĭko AN; Koval'chuk ML
Gig Sanit; 2009; (5):69-71. PubMed ID: 20000094
[TBL] [Abstract][Full Text] [Related]
5. [Radioactivity standards for construction materials].
Krisiuk EM
Gig Sanit; 1980 Dec; (12):32-4. PubMed ID: 7203065
[No Abstract] [Full Text] [Related]
6. Phantom organ shielding factors for radiation from walls of buildings.
Koblinger L
Health Phys; 1981 Feb; 40(2):243-5. PubMed ID: 7216805
[No Abstract] [Full Text] [Related]
7. Gamma activity and radiation dose in concrete building blocks used for construction of dwellings in Jos, Nigeria.
Ademola JA; Farai IP
Radiat Prot Dosimetry; 2006; 121(4):395-8. PubMed ID: 16702239
[TBL] [Abstract][Full Text] [Related]
8. Photon transmission of monoenergetic broad beams through gypsum wallboard.
Simpkin DJ
Health Phys; 1988 May; 54(5):561-3. PubMed ID: 3360610
[No Abstract] [Full Text] [Related]
9. [A method of calculating photon dose equivalent based on the revised technical standards of the Radiologic Protection Law (1)--conversion from absorbed dose in air to dose equivalent in shielding calculations].
Tanaka S; Suzuki T
Radioisotopes; 1989 Feb; 38(2):90-100. PubMed ID: 2710967
[No Abstract] [Full Text] [Related]
10. [Testing device for the measurement of important data in construction-technical radiation protection for the shielding of electron accelerators through the heaviest concrete and 1st measurement results].
Stockberg H; Andermahr M; Kosfeld R; Mitlacher H; Friedrich W; Sauermann PF
Fortschr Geb Rontgenstr Nuklearmed; 1973; 0(0):suppl:381-4. PubMed ID: 4367097
[No Abstract] [Full Text] [Related]
11. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
Rodgers JE
Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
[TBL] [Abstract][Full Text] [Related]
12. Shielding calculations below 100 kVp.
Raghavendran CP; Nagarajan PS; Venkataraman G
Health Phys; 1982 May; 42(5):717-23. PubMed ID: 7085312
[No Abstract] [Full Text] [Related]
13. [X-ray protection construction standardization manual. Part 2].
Ohno S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Jul; 60(7):965-7. PubMed ID: 15340277
[No Abstract] [Full Text] [Related]
14. Radiation protection of PFMA-1, a plasma focus for medical applications.
Fabbri A; Frignani M; Mannucci S; Mostacci D; Rocchi F; Sumini M; Teodori F; Angeli E; Tartari A; Cucchi G
J Radiol Prot; 2007 Dec; 27(4):465-70. PubMed ID: 18268377
[TBL] [Abstract][Full Text] [Related]
15. Calculation of conversion coefficients for clinical photon spectra using the MCNP code.
Lima MA; Silva AX; Crispim VR
Radiat Prot Dosimetry; 2004; 111(1):9-12. PubMed ID: 15367760
[TBL] [Abstract][Full Text] [Related]
16. The diagnostic X-ray protection characteristics of Ytong, an aerated concrete based building material.
Tsalafoutas IA; Yakoumakis E; Manetou A; Flioni-Vyza A
Br J Radiol; 1998 Sep; 71(849):944-9. PubMed ID: 10195009
[TBL] [Abstract][Full Text] [Related]
17. Neutron scattering in concrete and wood: Part II--Oblique incidence.
Facure A; Silva AX; Rivera JC; Falcão RC
Radiat Prot Dosimetry; 2008; 128(3):367-74. PubMed ID: 17673488
[TBL] [Abstract][Full Text] [Related]
18. [Radiation-hygienic control of building materials].
Chernik LA; Titov VK; Venkov VA
Gig Sanit; 1998; (5):41-4. PubMed ID: 9816786
[TBL] [Abstract][Full Text] [Related]
19. Use of gypsum wallboard for diagnostic X-ray protective barriers.
Glaze SA; Schneiders NJ; Bushong SC
Health Phys; 1979 May; 36(5):587-93. PubMed ID: 489312
[No Abstract] [Full Text] [Related]
20. Effect of windows and doors on the gamma shielding factor for typical houses in Brazil.
Salinas IC; Conti CC; Lopes RT
Health Phys; 2007 Mar; 92(3):251-6. PubMed ID: 17293697
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]