These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
102 related articles for article (PubMed ID: 423572)
1. Temperature-controlled oxygenator for isolated organ perfusion. Falzone MJ; Barrie WW; Schenk WG J Surg Res; 1979 Feb; 26(2):206-7. PubMed ID: 423572 [No Abstract] [Full Text] [Related]
2. A new simple temperature-controlled membrane oxygenator for the perfusion of isolated rat livers. Ogura M; Yamamoto Y; Ogura Y Experientia; 1985 Jan; 41(1):139-41. PubMed ID: 3967734 [TBL] [Abstract][Full Text] [Related]
3. Comparison of bubble and membrane oxygenators in short and long perfusions. Clark RE; Beauchamp RA; Magrath RA; Brooks JD; Ferguson TB; Weldon CS J Thorac Cardiovasc Surg; 1979 Nov; 78(5):655-66. PubMed ID: 491720 [TBL] [Abstract][Full Text] [Related]
4. Clinical comparison between membrane and bubble oxygenators in cardiopulmonary bypass. Fenchel G; Seybold-Epting W; Schmidt K; Stunkat R; Hoffmeister HE J Cardiovasc Surg (Torino); 1979; 20(4):419-22. PubMed ID: 479280 [TBL] [Abstract][Full Text] [Related]
5. Membrane and bubble oxygenators compared by preservation of myocardial function. Brown AH; Hassan MA; McMillan AB J Cardiovasc Surg (Torino); 1979; 20(3):233-40. PubMed ID: 447761 [TBL] [Abstract][Full Text] [Related]
6. Comparative evaluation of a new disposable rotating membrane oxygenator with bubble oxygenator. Subramanian VA; Berger RL Ann Thorac Surg; 1976 Jan; 21(1):48-54. PubMed ID: 2114 [TBL] [Abstract][Full Text] [Related]
7. The relative safety of an oxygenator. Svenmarker S; Häggmark S; Jansson E; Lindholm R; Appelblad M; Aberg T Perfusion; 1997 Sep; 12(5):289-92. PubMed ID: 9300473 [TBL] [Abstract][Full Text] [Related]
8. A small oxygenator for use with an organ perfusion system. Felts JM; Whayne TF IEEE Trans Biomed Eng; 1973 Sep; 20(5):382-4. PubMed ID: 4737897 [No Abstract] [Full Text] [Related]
9. Carbon Dioxide Flush of an Integrated Minimized Perfusion Circuit Prior to Priming Prevents Spontaneous Air Release Into the Arterial Line During Clinical Use. Stehouwer MC; de Vroege R; Hoohenkerk GJF; Hofman FN; Kelder JC; Buchner B; de Mol BA; Bruins P Artif Organs; 2017 Nov; 41(11):997-1003. PubMed ID: 28741663 [TBL] [Abstract][Full Text] [Related]
10. Reusable tubular membrane oxygenator for isolated organ hemoperfusion. Waugh WH; Bales TE; Nihei H J Appl Physiol; 1976 Mar; 40(3):476-82. PubMed ID: 931867 [TBL] [Abstract][Full Text] [Related]
12. Safety and efficacy of extracorporeal blood oxygenators: a review. Mortensen JD Med Instrum; 1978; 12(2):128-32. PubMed ID: 683036 [TBL] [Abstract][Full Text] [Related]
13. An ordinary membrane oxygenator for ex vivo perfusion of small organs. Habal MB; Birtch AG Med Instrum; 1975; 9(1):26-7. PubMed ID: 1128308 [No Abstract] [Full Text] [Related]
14. [The effect of various types of oxygenators on the pulmonary microvessels and surfactant activity]. Skorik VI; Perezhogin EV; Gaĭvoronskiĭ IV; Malikova TM Patol Fiziol Eksp Ter; 1989; (6):26-9. PubMed ID: 2628876 [TBL] [Abstract][Full Text] [Related]
15. Hyperthermic regional perfusion using membrane- instead of bubble-oxygenators. An experimental and clinical study. van Os J; Schraffordt Koops H; Oldhoff J; Wildevuur CR J Cardiovasc Surg (Torino); 1989; 30(4):523-32. PubMed ID: 2777859 [TBL] [Abstract][Full Text] [Related]