174 related articles for article (PubMed ID: 431117)
1. Runaway pump head: new cause of gas embolism during cardiopulmonary bypass.
Kurusz M; Shaffer CW; Christman EW; Tyers GF
J Thorac Cardiovasc Surg; 1979 May; 77(5):792-5. PubMed ID: 431117
[TBL] [Abstract][Full Text] [Related]
2. Massive air embolism during cardiopulmonary bypass. Causes, prevention, and management.
Mills NL; Ochsner JL
J Thorac Cardiovasc Surg; 1980 Nov; 80(5):708-17. PubMed ID: 7431967
[TBL] [Abstract][Full Text] [Related]
3. [A case of massive air embolism during cardiopulmonary bypass].
Morimura K; Suehiro S; Shibata T; Minamimura H; Hattori K; Kinoshita H
Nihon Kyobu Geka Gakkai Zasshi; 1995 Jul; 43(7):1059-62. PubMed ID: 7561320
[TBL] [Abstract][Full Text] [Related]
4. A clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators.
Pearson DT; Holden MP; Poslad SJ; Murray A; Waterhouse PS
Life Support Syst; 1984; 2(4):252-66. PubMed ID: 6441873
[TBL] [Abstract][Full Text] [Related]
5. Successful survival from massive air embolism and circulatory arrest during cardio-pulmonary bypass.
Lin TC; Sia SL; Wong KL; Lai KB; Chuang HI; Sit KF; Wei TT
Ma Zui Xue Za Zhi; 1992 Dec; 30(4):265-70. PubMed ID: 1344242
[No Abstract] [Full Text] [Related]
6. Carbon Dioxide Flush of an Integrated Minimized Perfusion Circuit Prior to Priming Prevents Spontaneous Air Release Into the Arterial Line During Clinical Use.
Stehouwer MC; de Vroege R; Hoohenkerk GJF; Hofman FN; Kelder JC; Buchner B; de Mol BA; Bruins P
Artif Organs; 2017 Nov; 41(11):997-1003. PubMed ID: 28741663
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter.
Salavitabar A; Qiu F; Kunselman A; Ündar A
Perfusion; 2010 Nov; 25(6):409-15. PubMed ID: 20699287
[TBL] [Abstract][Full Text] [Related]
8. Removal of Gross Air Embolization from Cardiopulmonary Bypass Circuits with Integrated Arterial Line Filters: A Comparison of Circuit Designs.
Reagor JA; Holt DW
J Extra Corpor Technol; 2016 Mar; 48(1):19-22. PubMed ID: 27134304
[TBL] [Abstract][Full Text] [Related]
9. Massive arterial air embolism during cardiopulmonary bypass: antegrade blood cardioplegia delivered by the pump--an accident waiting to happen.
Jones NC; Howell CW
Perfusion; 1996 Mar; 11(2):157-61. PubMed ID: 8740356
[TBL] [Abstract][Full Text] [Related]
10. First clinical experience with the air purge control and electrical remote-controlled tubing clamp in mini bypass.
Huybregts RM; Veerman DP; Vonk AB; Nesselaar AF; Paulus RC; Thone-Passchier DH; Smith AL; de Vroege R
Artif Organs; 2006 Sep; 30(9):721-4. PubMed ID: 16934103
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound detection of micro-emboli in the middle cerebral artery during cardiopulmonary bypass surgery.
Deverall PB; Padayachee TS; Parsons S; Theobold R; Battistessa SA
Eur J Cardiothorac Surg; 1988; 2(4):256-60. PubMed ID: 3078422
[TBL] [Abstract][Full Text] [Related]
12. Separation of craniopagus Siamese twins using cardiopulmonary bypass and hypothermic circulatory arrest.
Cameron DE; Reitz BA; Carson BS; Long DM; Dufresne CR; Vander Kolk CA; Maxwell LG; Tilghman DM; Nichols DG; Wetzel RC
J Thorac Cardiovasc Surg; 1989 Nov; 98(5 Pt 2):961-7. PubMed ID: 2682024
[TBL] [Abstract][Full Text] [Related]
13. Comparison of mini-cardiopulmonary bypass system with air-purge device to conventional bypass system.
Ti LK; Goh BL; Wong PS; Ong P; Goh SG; Lee CN
Ann Thorac Surg; 2008 Mar; 85(3):994-1000. PubMed ID: 18291186
[TBL] [Abstract][Full Text] [Related]
14. Gaseous microemboli: sources, causes, and clinical considerations.
Kurusz M
Med Instrum; 1985; 19(2):73-6. PubMed ID: 4000011
[TBL] [Abstract][Full Text] [Related]
15. Autoregulated extra- and intracorporeal pump system for perfusion.
Ade WR; Hino T; Kaizuka H; Wada J
Int Surg; 1992; 77(2):108-10. PubMed ID: 1644535
[TBL] [Abstract][Full Text] [Related]
16. Air embolism and other accidents using pump oxygenators.
Stoney WS; Alford WC; Burrus GR; Glassford DM; Thomas CS
Ann Thorac Surg; 1980 Apr; 29(4):336-40. PubMed ID: 7362326
[TBL] [Abstract][Full Text] [Related]
17. Integrated Oxygenator FX05.
Horton SB; Donath S; Thuys CA; Bennett MJ; Augustin SL; Horton AM; Schultz BJ; Bottrell SJ; Konstantinov I; d'Udekem Y; Brizard C
ASAIO J; 2011; 57(6):522-6. PubMed ID: 21970981
[TBL] [Abstract][Full Text] [Related]
18. Successful management of a case of massive air embolism from cardiopulmonary bypass with retrograde cerebral perfusion in a child.
Sahu MK; Ingole PR; Bisoi AK; Venugopal P
J Cardiothorac Vasc Anesth; 2006 Feb; 20(1):80-1. PubMed ID: 16458220
[No Abstract] [Full Text] [Related]
19. The bubble oxygenator as a source of gaseous microemboli.
Yost G
Med Instrum; 1985; 19(2):67-9. PubMed ID: 4000009
[TBL] [Abstract][Full Text] [Related]
20. Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.
Myers GJ; Voorhees C; Haynes R; Eke B
J Extra Corpor Technol; 2009 Mar; 41(1):20-7. PubMed ID: 19361028
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]