These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 434601)

  • 1. Accuracy sensitivity to carboxyhemoglobin, and speed of response of the Hewlett-Packard 47201A ear oximeter.
    Douglas NJ; Brash HM; Wraith PK; Calverley PM; Leggett RJ; McElderry L; Flenley DC
    Am Rev Respir Dis; 1979 Feb; 119(2):311-3. PubMed ID: 434601
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The accuracy of the Hewlett-Packard 47201A ear oximeter below 50% saturation.
    Stradling JR
    Bull Eur Physiopathol Respir; 1982; 18(5):791-4. PubMed ID: 6927531
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ear oximetry: accuracy and practicability in the assessment of arterial oxygenation.
    Saunders NA; Powles AC; Rebuck AS
    Am Rev Respir Dis; 1976 Jun; 113(6):745-9. PubMed ID: 937815
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Accuracy of an the ear oximeter Biox-III and its sensitivity to carboxyhemoglobin in Mexico City].
    PĂ©rez-Padilla JR; Bracamonte-Peraza R; Manrique G; Ruiz-Primo ME
    Arch Inst Cardiol Mex; 1986; 56(4):303-7. PubMed ID: 2945522
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The accuracy and response characteristics of a simplified ear oximeter.
    Chapman KR; D'Urzo A; Rebuck AS
    Chest; 1983 Jun; 83(6):860-4. PubMed ID: 6851688
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.
    Ries AL; Farrow JT; Clausen JL
    Am Rev Respir Dis; 1985 Sep; 132(3):685-9. PubMed ID: 4037542
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous in vivo measurement of arterial oxygen saturation by oximetry.
    Flick MR; Block AJ
    Heart Lung; 1977; 6(6):990-3. PubMed ID: 244328
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of a new reflectance oximeter with the Hewlett-Packard ear oximeter.
    Decker MJ; Dickensheets D; Arnold JL; Cheung PW; Strohl KP
    Biomed Instrum Technol; 1990; 24(2):122-6. PubMed ID: 2322755
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100.
    West P; George CF; Kryger MH
    Sleep; 1987 Jun; 10(3):263-71. PubMed ID: 3629089
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous comparison of three noninvasive oximeters in healthy volunteers.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    Med Instrum; 1987 Jun; 21(3):183-8. PubMed ID: 3614041
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of three transmittance oximeters.
    Strohl KP; House PM; Holic JF; Fouke JM; Cheung PW
    Med Instrum; 1986; 20(3):143-9. PubMed ID: 3724588
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of carboxyhemoglobin on the accuracy of mixed venous oximetry monitors in dogs.
    Haney M; Tait AR; Tremper KK
    Crit Care Med; 1994 Jul; 22(7):1181-5. PubMed ID: 8026210
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ear oximetry in clinical practice.
    Chaudhary BA; Burki NK
    Am Rev Respir Dis; 1978 Jan; 117(1):173-5. PubMed ID: 619718
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Datascope ACCUSAT pulse oximeter in healthy adults.
    Mendelson Y; Kent JC; Shahnarian A; Welch GW; Giasi RM
    J Clin Monit; 1988 Jan; 4(1):59-63. PubMed ID: 3339392
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automatic detection at the polygraph of malposition of the Hewlett-Packard ear oximeter.
    Lucas EA; Wilson FJ; Johnson W
    Sleep; 1984; 7(3):272-3. PubMed ID: 6484431
    [No Abstract]   [Full Text] [Related]  

  • 16. Calibration of a new ear oximeter in humans during exposure to centrifugation.
    Besch EL; Baumgardner FW; Burton RR; Gillingham KK; McPherson RF; Leverett SD
    J Appl Physiol Respir Environ Exerc Physiol; 1978 Mar; 44(3):483-7. PubMed ID: 632190
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ear oximetry during combined hypoxia and exercise.
    Smyth RJ; D'Urzo AD; Slutsky AS; Galko BM; Rebuck AS
    J Appl Physiol (1985); 1986 Feb; 60(2):716-9. PubMed ID: 3949671
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy.
    Chen Z; Yang S; Xing D
    Opt Lett; 2012 Aug; 37(16):3414-6. PubMed ID: 23381275
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of the Rad-57 pulse co-oximeter compared with standard laboratory carboxyhemoglobin measurement.
    O'Reilly M
    Ann Emerg Med; 2010 Oct; 56(4):442-4; author reply 444-5. PubMed ID: 20868919
    [No Abstract]   [Full Text] [Related]  

  • 20. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement.
    Touger M; Birnbaum A; Wang J; Chou K; Pearson D; Bijur P
    Ann Emerg Med; 2010 Oct; 56(4):382-8. PubMed ID: 20605259
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.