These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 436407)

  • 21. Three-dimensional dose calculations for radiation treatment planning. Photon Treatment Planning Collaborative Working Group.
    Int J Radiat Oncol Biol Phys; 1991 May; 21(1):25-36. PubMed ID: 2032893
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of Cartesian coordinates and radiation doses in points determined with stereo x-ray techniques.
    Storchi PR; van Kleffens HJ
    Comput Programs Biomed; 1979 Mar; 9(2):141-8. PubMed ID: 761457
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Monte Carlo evaluation of the effect of inhomogeneities on dose calculation for low energy photons intra-operative radiation therapy in pelvic area.
    Chiavassa S; Buge F; Hervé C; Delpon G; Rigaud J; Lisbona A; Supiot S
    Phys Med; 2015 Dec; 31(8):956-962. PubMed ID: 26420445
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Absorbed dose distribution of electron beams in uniform and inhomogeneous media.
    Brahme A; Lax I
    Acta Radiol Suppl; 1983; 364():61-72. PubMed ID: 6316742
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A 3-D beam subtraction method for inhomogeneity correction in high energy X-ray radiotherapy.
    Kappas K; Rosenwald JC
    Radiother Oncol; 1986 Mar; 5(3):223-33. PubMed ID: 3085171
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Electron beam dose planning using discrete Gaussian beams. Mathematical background.
    Brahme A; Lax I; Andreo P
    Acta Radiol Oncol; 1981; 20(2):147-58. PubMed ID: 6270968
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Dose to normal tissues outside the radiation therapy patient's treated volume: a review of different radiation therapy techniques.
    Purdy JA
    Health Phys; 2008 Nov; 95(5):666-76. PubMed ID: 18849701
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction.
    van Elmpt WJ; Nijsten SM; Dekker AL; Mijnheer BJ; Lambin P
    Med Phys; 2007 Jul; 34(7):2816-26. PubMed ID: 17821989
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Physical factors affecting absorbed dose to the skin from cobalt-60 gamma rays and 25-MV x rays.
    Gagnon WF; Horton JL
    Med Phys; 1979; 6(4):285-90. PubMed ID: 113655
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Calculation of high-energy electron dose distributions in tissue-equivalent media. I. Determination of the dose function of point unidirectional sources.
    Kozlov AP; Shishov VA
    Strahlentherapie; 1982 May; 158(5):298-304. PubMed ID: 7112625
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Improved method for the design of tissue compensators.
    Shragge PC; Patterson MS
    Med Phys; 1981; 8(6):885-91. PubMed ID: 7322085
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Principles of a treatment planning program with separate calculation of dose distributions for neutrons and gamma rays.
    Meissner P; Rassow J
    Strahlentherapie Sonderb; 1981; 77():162-9. PubMed ID: 6820992
    [No Abstract]   [Full Text] [Related]  

  • 33. Use of the computer in high-energy electron therapy.
    Poretti GG; Ionesco-Farca F
    Radiol Clin (Basel); 1978; 47(2):139-53. PubMed ID: 625554
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [An analytical method to calculate electron dose distributions. Part I: Method (author's transl)].
    Fehrentz D; Kimmig B; Ihnen E; Schröder-Babo P
    Strahlentherapie; 1979 Apr; 155(4):248-53. PubMed ID: 452050
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Consideration of inhomogeneities in irradiation planning. 2. Influence of inhomogeneities on the shape of the depth dose curve in water with 42 MeV X-rays (author's transl)].
    Zwicker H; Felix R
    Strahlentherapie; 1977 Jan; 153(1):46-50. PubMed ID: 402040
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Experience in implementing the Mark III Rad 8 system for radiotherapy dose computations.
    Wilkinson JM; Redmond WJ
    Br J Radiol; 1975 Sep; 48(573):732-8. PubMed ID: 1182432
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculations.
    Cygler J; Battista JJ; Scrimger JW; Mah E; Antolak J
    Phys Med Biol; 1987 Sep; 32(9):1073-86. PubMed ID: 3671495
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Models in radiotherapy: volume effects.
    Schultheiss TE; Orton CG; Peck RA
    Med Phys; 1983; 10(4):410-5. PubMed ID: 6888354
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monte Carlo dosimetry modeling of focused kV x-ray radiotherapy of eye diseases with potential nanoparticle dose enhancement.
    Yan H; Ma X; Sun W; Mendez S; Stryker S; Starr-Baier S; Delliturri G; Zhu D; Nath R; Chen Z; Roberts K; MacDonald CA; Liu W
    Med Phys; 2018 Oct; 45(10):4720-4733. PubMed ID: 30133705
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fluence and absorbed dose in high energy electron beams.
    Andreo P; Brahme A
    Acta Radiol Suppl; 1983; 364():25-33. PubMed ID: 6316737
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.