These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

302 related articles for article (PubMed ID: 43747)

  • 1. Simultaneous transcutaneous oxygen tension and tissue pH monitoring in sick neonates.
    Vidyasagar D; Asonye UO
    Birth Defects Orig Artic Ser; 1979; 15(4):395-8. PubMed ID: 43747
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of continuous transcutaneous PO2 (Hellige) in respiratory distress syndrome of the newborn.
    Duc G; Frei H; Klar H; Tuchschmid P
    Birth Defects Orig Artic Ser; 1979; 15(4):305-13. PubMed ID: 534710
    [No Abstract]   [Full Text] [Related]  

  • 3. Transcutaneous monitoring of PO2 (tcPO2) in sick newborn babies: three years of clinical experience.
    Hohenauer L
    Birth Defects Orig Artic Ser; 1979; 15(4):375-6. PubMed ID: 534720
    [No Abstract]   [Full Text] [Related]  

  • 4. Interpretation of tcPO2 recordings for quick evaluation of postpartum adaptation.
    Schachinger H; Schneider H; Huch R; Huch A
    Birth Defects Orig Artic Ser; 1979; 15(4):495-501. PubMed ID: 534732
    [No Abstract]   [Full Text] [Related]  

  • 5. Transcutaneous oxygen tension measurement I. Age variation and reproducibility.
    Gøthgen J; Jacobsen E
    Acta Anaesthesiol Scand Suppl; 1978; 67():66-70. PubMed ID: 278457
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Transcutaneous measurement of partial pressure of oxygen in paediatric intensive care (author's transl)].
    Emmrich P; Stechele U; Huch R; Huch A
    Dtsch Med Wochenschr; 1975 Sep; 100(38):1892,1897-901. PubMed ID: 1192952
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous comparison of in vitro and in vivo calibrated transcutaneous oxygen tension with arterial oxygen tension in infants.
    Pollitzer MJ; Reynolds EO; Morgan AK; Soutter LP; Parker D; Delpy DT; Whitehead MD
    Birth Defects Orig Artic Ser; 1979; 15(4):295-304. PubMed ID: 534709
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcutaneous measurement of carbon dioxide tension: effect of sleep state in term infants.
    Martin RJ; Herrell N; Pultusker M
    Pediatrics; 1981 May; 67(5):622-5. PubMed ID: 6789297
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of transcutaneous oxygen tension with arterial oxygen tension in newborn infants with severe respiratory illnesses.
    le Souëf PN; Morgan AK; Soutter LP; Reynolds EO; Parker D
    Pediatrics; 1978 Nov; 62(5):692-7. PubMed ID: 724311
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcutaneous oxygen tension measurement II. The influence of halothane and hypotension.
    Gøthgen I; Jacobsen E
    Acta Anaesthesiol Scand Suppl; 1978; 67():71-5. PubMed ID: 278458
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PO2 in the seventies.
    Indyk L
    Pediatrics; 1975 Feb; 55(2):153-6. PubMed ID: 235113
    [No Abstract]   [Full Text] [Related]  

  • 13. Reliability of skin (tc)PO2 electrode heating power as a continuous noninvasive monitor of mean arterial pressure in sick newborns.
    Peabody JL; Willis MM; Gregory GA; Severinghaus JW
    Birth Defects Orig Artic Ser; 1979; 15(4):127-33. PubMed ID: 534692
    [No Abstract]   [Full Text] [Related]  

  • 14. A comparison of PO2 monitoring techniques in newborn infants.
    Lewis IG; Haslam RR
    Aust Paediatr J; 1984 Nov; 20(4):309-11. PubMed ID: 6442139
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new tcPO2 electrode and its application to adults.
    Hagihara B; Fukai T; Hachino Y; Nakayama K; Ishibashi F; Ohta A; Ohminato S; Takemura H; Hasegawa T; Kurachi K; Okada Y; Sugimoto T; Nomura K; Yoshida K
    Birth Defects Orig Artic Ser; 1979; 15(4):75-90. PubMed ID: 534749
    [No Abstract]   [Full Text] [Related]  

  • 16. Interpretation of the tcPO2 curve in adult patients in an intensive care unit.
    Rooth G; Hedstrand U; Ogren C
    Birth Defects Orig Artic Ser; 1979; 15(4):557-71. PubMed ID: 534740
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Is transcutaneous oxygen tension independent of variations in blood flow and in arterial blood pressure?
    Eickhoff JH; Jacobsen E
    Biotelem Patient Monit; 1982; 9(3):175-84. PubMed ID: 7159703
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of intermittant bag ventilation on tcPO2 of preterm infants on continuous positive airway pressure.
    Okken A; Rubin L; Martin RJ
    Birth Defects Orig Artic Ser; 1979; 15(4):393-4. PubMed ID: 394771
    [No Abstract]   [Full Text] [Related]  

  • 19. Clinical experience using the Hagihara electrode tcPO2 monitor.
    Takemura H; Ohminato S; Hasegawa T; Kurachi K; Hagihara B; Hachino Y; Nakayama K; Yoshida K; Fukai T; Nomura K
    Birth Defects Orig Artic Ser; 1979; 15(4):377-81. PubMed ID: 534721
    [No Abstract]   [Full Text] [Related]  

  • 20. Continuous transcutaneous PO2 monitoring in vital distress of children.
    Bompard Y; Beaufils F; Azancot A; Asensi D
    Birth Defects Orig Artic Ser; 1979; 15(4):383-6. PubMed ID: 394770
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 16.