These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 4412135)

  • 1. Automated enzymatic micromethod for determination of uric acid in serum and urine with a centrifugal analyzer.
    Pesce MA; Bodourian SH; Nicholson JF
    Clin Chem; 1974 Sep; 20(9):1231-3. PubMed ID: 4412135
    [No Abstract]   [Full Text] [Related]  

  • 2. A precise semi-automated uricase method for determining uric acid in serum or urine.
    MacRae AR
    Clin Biochem; 1977 Feb; 10(1):29-31. PubMed ID: 837524
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Technical bulletin No. 31. Determination of uric acid in blood and in urine.
    Watts RW
    Ann Clin Biochem; 1974 Jul; 11(4):103-11. PubMed ID: 4608659
    [No Abstract]   [Full Text] [Related]  

  • 4. Enzyme electrode sensing oxygen for uric acid in serum and urine.
    Nanjo M; Guilbault GG
    Anal Chem; 1974 Oct; 46(12):1769-72. PubMed ID: 4413256
    [No Abstract]   [Full Text] [Related]  

  • 5. The reliability of a mechanized procedure (Perkin-Elmer C4) for the Enzymatic determination of uric acid according to Kageyama.
    Haeckel R
    J Clin Chem Clin Biochem; 1976 Apr; 14(4):165-71. PubMed ID: 1271017
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The application of a sensitive uricase-peroxidase couple reaction to a centrifugal fast analyser for the determination of uric acid.
    Artiss JD; Entwistle WM
    Clin Chim Acta; 1981 Nov; 116(3):301-9. PubMed ID: 7296893
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development and improvement of a commercial uric acid enzymatic determination kit on a centrifugal fast analyzer.
    Zoppi F; Peracino A; Marcovina S; Fenili D
    J Clin Chem Clin Biochem; 1980 Jan; 18(1):59-65. PubMed ID: 6987330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An automated enzymatic spectrophotometric method for the determination of uric acid.
    Steele TH
    Tech Bull Regist Med Technol; 1969 Dec; 39(12):270-4. PubMed ID: 5377445
    [No Abstract]   [Full Text] [Related]  

  • 9. Enzyme-coupled measurement of uric acid in serum with a centrifugal analyzer.
    White RM; Cross RE; Savory J
    Clin Chem; 1977 Sep; 23(9):1538-40. PubMed ID: 890896
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Automatic dosage of uric acid by urate oxydase. Comparison with Praetorius' methods].
    Pollet J; Galliot M
    Ann Biol Clin (Paris); 1975; 33(2):75-80. PubMed ID: 241280
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved automated kinetic determination of uric acid in serum by use of uricase/catalase/aldehyde dehydrogenase.
    Bartl K; Brandhuber M; Ziegenhorn J
    Clin Chem; 1979 Apr; 25(4):619-21. PubMed ID: 466770
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Adaptation of the SMAC for the determination of uric acid with an uricase/perioxidase procedure (author's transl)].
    Scholer A; Müller E; Toth F; Vonderschmitt DJ
    J Clin Chem Clin Biochem; 1978 Apr; 16(4):255-7. PubMed ID: 641455
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adaptation of blank-corrected methods for measurement of total and conjugated bilirubin and uric acid to the centrifugal analyzer.
    Cross RE; Heintges MG; Savory J; Wentz PW
    Clin Chem; 1976 Apr; 22(4):429-33. PubMed ID: 1253424
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of immobilized enzymes in automated clinical analysis: determination of uric acid and glucose using immobilized enzymes in column form.
    Endo J; Tabata M; Okada S; Murachi T
    Clin Chim Acta; 1979 Jul; 95(2):411-7. PubMed ID: 527227
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new automated determination of uric acid.
    Breebaart K; Haan AM
    Z Klin Chem Klin Biochem; 1972 Jan; 10(1):17-20. PubMed ID: 4680996
    [No Abstract]   [Full Text] [Related]  

  • 16. [Enzymatic colorimetric micromethod for the determination of uric acid].
    Lartillot S; Vogel C
    Biochimie; 1973; 55(6):829-32. PubMed ID: 4797826
    [No Abstract]   [Full Text] [Related]  

  • 17. A direct colorimetric determination of uric acid in serum and urine with uricase-catalase system.
    Kageyama N
    Clin Chim Acta; 1971 Feb; 31(2):421-6. PubMed ID: 5573684
    [No Abstract]   [Full Text] [Related]  

  • 18. Determination of uric acid by an anion-exchange column chromatography.
    Hsu DS; Chen SS
    Anal Biochem; 1987 May; 163(1):238-41. PubMed ID: 3619024
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automated determination of uric acid, with use of a uricase-peroxidase system.
    Gochman N; Schmitz JM
    Clin Chem; 1971 Dec; 17(12):1154-9. PubMed ID: 5118153
    [No Abstract]   [Full Text] [Related]  

  • 20. Measuring urate in the Technicon SMAC by using unbound uricase and omitting dialysis.
    O'Leary N; Devoy J; Duggan PF
    Clin Chem; 1983 Nov; 29(11):1993-4. PubMed ID: 6627647
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.