These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 441528)

  • 1. [Computation of the average in- and expiratory airway resistance (author's transl)].
    Wiessmann KJ; Steinijans VW
    Respiration; 1979; 37(1):15-22. PubMed ID: 441528
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The estimation of resistance in nonlinear pressure-flow-curves (author's transl)].
    Reinert M; Heise D; Trendelenburg F
    Pneumonologie; 1975 Sep; 152(1-3):147-56. PubMed ID: 1187386
    [No Abstract]   [Full Text] [Related]  

  • 3. Influence of breathing rate on airway resistance and compliance measurements.
    Chester EH; Ostrander LE; Franck JB; Niewoehner DE
    Respir Physiol; 1974 Jun; 20(3):337-51. PubMed ID: 4837696
    [No Abstract]   [Full Text] [Related]  

  • 4. Comparative measurements of airway resistance.
    Matthys H; Orth U
    Respiration; 1975; 32(2):121-34. PubMed ID: 1118676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical use of the measurement of airway resistance during spontaneous respiration.
    Homma T; Fujioka K; Uchida Y; Saitoh T; Matsuki K; Hasegawa S
    Respiration; 1984; 45(4):360-71. PubMed ID: 6473920
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [On the abnormal respiratory volume vs. body volume diagram and its mechanical genesis (author's transl)].
    Berger D; Nolte D
    Pneumonologie; 1975 Sep; 152(1-3):141-5. PubMed ID: 1187385
    [No Abstract]   [Full Text] [Related]  

  • 7. [Airway resistance curves in obstructive respiratory tract diseases. 8 types of airway resistance curves in spontaneous respiration].
    Ulmer WT; Marek W; Rasche K
    Fortschr Med; 1988 Nov; 106(33):663-4, 665-6, 667. PubMed ID: 3061907
    [No Abstract]   [Full Text] [Related]  

  • 8. [Assessment of respiratory function by body plethysmography (author's transl)].
    Schindl R
    Wien Klin Wochenschr; 1980 Jan; 92(2):59-62. PubMed ID: 6929634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effective airway resistance: a reliable variable from body plethysmography.
    Holland WP; Verbraak AF; Bogaard JM; Boender W
    Clin Phys Physiol Meas; 1986 Nov; 7(4):319-31. PubMed ID: 3791878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computation of the equivalent airway resistance: a comparison with routine evaluations of plethysmographic measurements.
    Hantos Z; Galgóczy G; Daróczy B; Dombos K
    Respiration; 1978; 36(2):64-72. PubMed ID: 663423
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Study on the relation of values of total respiratory-airway resistance Rt and mean resistance R].
    Skalník L; Stĕtka F; Riedel M; Holcík J
    Vnitr Lek; 1974 Jan; 20(1):35-9. PubMed ID: 4847014
    [No Abstract]   [Full Text] [Related]  

  • 12. [Roentgenographic and bodyplethysmographic determination of total lung capacity in normal persons and patients with obstructive and restrictive lung function disturbances (author's transl)].
    Reinert M
    Prax Klin Pneumol; 1980 Apr; 34(4):229-34. PubMed ID: 7433410
    [No Abstract]   [Full Text] [Related]  

  • 13. [Influence of airway resistance and lung compliance on flow-volume curve (author's transl)].
    Kado T; Miyatake H; Matsuda Y; Fukuzaki H; Sera K
    Nihon Kyobu Shikkan Gakkai Zasshi; 1981 May; 19(5):297-301. PubMed ID: 7289255
    [No Abstract]   [Full Text] [Related]  

  • 14. [On-line computation of a mean airway resistance in body plethysmography (author's transl)].
    Smidt U; Finkenzeller P; Rennings C
    Pneumonologie; 1975; 151(3):223-31. PubMed ID: 1187380
    [No Abstract]   [Full Text] [Related]  

  • 15. [Comparative measurement of nasal airway resistance by means of posterior rhinometry, body plethysmography and a modified interruption technique (author's transl)].
    Schumann K
    HNO; 1975 Jan; 23(1):24-8. PubMed ID: 1120724
    [No Abstract]   [Full Text] [Related]  

  • 16. [Continuous measurement of airway resistance during spontaneous breathing].
    Taniai S; Tsukimoto K; Sakaino H; Ichioka M; Shimase J; Chida M; Miyazato I; Takeuchi J; Matsuki K
    Nihon Kyobu Shikkan Gakkai Zasshi; 1987 Sep; 25(9):951-8. PubMed ID: 3444148
    [No Abstract]   [Full Text] [Related]  

  • 17. Failure of body plethysmography to reflect functional deterioration seen in chronic obstructive pulmonary disease.
    Sobol BJ; Emirgil C
    Chest; 1973 Mar; 63(3):391-5. PubMed ID: 4690887
    [No Abstract]   [Full Text] [Related]  

  • 18. The perception of changes in airflow resistance in normal subjects and patients with chronic airways obstruction.
    Gottfried SB; Altose MD; Kelsen SG; Fogarty CM; Cherniack NS
    Chest; 1978 Feb; 73(2 Suppl):286-8. PubMed ID: 340163
    [No Abstract]   [Full Text] [Related]  

  • 19. Effect of panting frequency on the plethysmographic determination of thoracic gas volume in chronic obstructive pulmonary disease.
    Shore SA; Huk O; Mannix S; Martin JG
    Am Rev Respir Dis; 1983 Jul; 128(1):54-9. PubMed ID: 6870070
    [No Abstract]   [Full Text] [Related]  

  • 20. [Breath rate as a function of parameters of pulmonary function in body plethysmography (author's transl)].
    Börngen U
    Med Klin; 1975 Feb; 70(9):367-76. PubMed ID: 1124049
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.