These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 4420479)

  • 1. Modified laminar flow biological safety cabinet.
    McGarrity GJ; Coriell LL
    Appl Microbiol; 1974 Oct; 28(4):647-50. PubMed ID: 4420479
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mass airflow cabinet for control of airborne infection of laboratory rodents.
    McGarrity GJ; Coriell LL
    Appl Microbiol; 1973 Aug; 26(2):167-72. PubMed ID: 4355261
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bacteriological testing of a modified laminar flow microbiological safety cabinet.
    Heidt PJ
    Antonie Van Leeuwenhoek; 1982; 48(4):373-81. PubMed ID: 7149701
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of crossdrafts on the performance of a biological safety cabinet.
    Rake BW
    Appl Environ Microbiol; 1978 Aug; 36(2):278-83. PubMed ID: 100057
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microbiological studies on the performance of a laminar airflow biological cabinet.
    McDade JJ; Sabel FL; Akers RL; Walker RJ
    Appl Microbiol; 1968 Jul; 16(7):1086-92. PubMed ID: 4874462
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of exhaust-protective (class I) biological 'safety' cabinets.
    Newsom SW
    J Clin Pathol; 1979 Jun; 32(6):576-83. PubMed ID: 469014
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improving the biosafety of cell sorting by adaptation of a cell sorting system to a biosafety cabinet.
    Lennartz K; Lu M; Flasshove M; Moritz T; Kirstein U
    Cytometry A; 2005 Aug; 66(2):119-27. PubMed ID: 15973698
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Containment of microbial aerosols in a microbiological safety cabinet.
    Barbeito MS; Taylor LA
    Appl Microbiol; 1968 Aug; 16(8):1225-9. PubMed ID: 4877500
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Class II (laminar flow) biological safety cabinet.
    Newsom SW
    J Clin Pathol; 1979 May; 32(5):505-13. PubMed ID: 469008
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of laminar flow microbiological safety cabinets.
    Staat RH; Beakley JW
    Appl Microbiol; 1968 Oct; 16(10):1478-82. PubMed ID: 4971719
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flow and performance of an air-curtain biological safety cabinet.
    Huang RF; Chou CI
    Ann Occup Hyg; 2009 Jun; 53(4):425-40. PubMed ID: 19398506
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of filters for removal of bacteriophages from air.
    Washam CJ; Black CH; Sandine WE; Elliker PR
    Appl Microbiol; 1966 Jul; 14(4):497-505. PubMed ID: 5927020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology.
    Bohannon JK; Janosko K; Holbrook MR; Barr J; Pusl D; Bollinger L; Coe L; Hensley LE; Jahrling PB; Wada J; Kuhn JH; Lackemeyer MG
    J Vis Exp; 2016 Oct; (116):. PubMed ID: 27768036
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A test system for the biological safety cabinet.
    Newsom SW
    J Clin Pathol; 1974 Jul; 27(7):585-9. PubMed ID: 4214380
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a class III biological safety cabinet for enclosure of an ultracentrifuge.
    Chatigny MA; Dunn S; Ishimaru K; Eagleson JA; Prusiner SB
    Appl Environ Microbiol; 1979 Nov; 38(5):934-9. PubMed ID: 543704
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the effect of media velocity on filter efficiency and most penetrating particle size of nuclear grade high-efficiency particulate air filters.
    Alderman SL; Parsons MS; Hogancamp KU; Waggoner CA
    J Occup Environ Hyg; 2008 Nov; 5(11):713-20. PubMed ID: 18726819
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of airflow rates and operator activity on containment of bacterial aerosols in a class II safety cabinet.
    Macher JM; First MW
    Appl Environ Microbiol; 1984 Sep; 48(3):481-5. PubMed ID: 6437327
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bedding disposal cabinet for containment of aerosols generated by animal cage cleaning procedures.
    Baldwin CL; Sabel FL; Henke CB
    Appl Environ Microbiol; 1976 Feb; 31(2):322-4. PubMed ID: 826219
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the Edgegard laminar flow hood.
    Coriell LL; McGarrity GJ
    Appl Microbiol; 1970 Sep; 20(3):474-9. PubMed ID: 5485728
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bacteriological evaluation of a mobile laminar cross-flow unit for surgery, under laboratory circumstances.
    van der Waaij D; Wiegersma N; Dankert J
    J Hyg (Lond); 1976 Feb; 76(1):1-10. PubMed ID: 1107410
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.