These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

64 related articles for article (PubMed ID: 4426829)

  • 21. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study.
    Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N
    J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Computational comparison of reamed versus unreamed intramedullary tibial nails.
    Gómez-Benito MJ; Fornells P; García-Aznar JM; Seral B; Seral-Iñnigo F; Doblaré M
    J Orthop Res; 2007 Feb; 25(2):191-200. PubMed ID: 17089377
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Increase in stability of the fixation external using a modified steinmann-pin for cancellous bone (author's transl)].
    Faensen M; Hahn F; Jahnke R
    Unfallheilkunde; 1981 Sep; 84(9):382-6. PubMed ID: 7292789
    [No Abstract]   [Full Text] [Related]  

  • 24. [Experimental studies of the effect of immobilization on bone solidity and elasticity as well as on the regeneration ability in remobilization].
    Haike HJ; Heymann P; Wagner K
    Z Orthop Ihre Grenzgeb; 1966 Dec; 102(2):200-8. PubMed ID: 4231555
    [No Abstract]   [Full Text] [Related]  

  • 25. [Ipsilateral fractures of the femoral and tibial diaphyses].
    Schiedts D; Mukisi M; Bouger D; Bastaraud H
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(6):535-40. PubMed ID: 9122525
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Treatment of fractures of the posterior border of the tibia].
    Iusupov FS; Nigmatullin KK; Evseev VI
    Ortop Travmatol Protez; 1977 May; (5):75-7. PubMed ID: 896183
    [No Abstract]   [Full Text] [Related]  

  • 27. [Treatment of open fractures of the tibia associated with defects of the soft tissue using an external fixation frame--Poldi IV].
    Capla D; Kundrát J
    Acta Chir Orthop Traumatol Cech; 1984 Apr; 51(2):145-56. PubMed ID: 6720213
    [No Abstract]   [Full Text] [Related]  

  • 28. Experimental model of tibial plateau fracture for biomechanical testing.
    Ali AM; Saleh M; Bolongaro S; Yang L
    J Biomech; 2006; 39(7):1355-60. PubMed ID: 15936763
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Development of a variable stiffness external fixation system for stabilization of segmental defects of the tibia.
    Tencer AF; Claudi B; Pearce S; Bucholz RW; Johnson KD
    J Orthop Res; 1984; 1(4):395-404. PubMed ID: 6491789
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Treatment of closed tibial fractures.
    Schmidt AH; Finkemeier CG; Tornetta P
    Instr Course Lect; 2003; 52():607-22. PubMed ID: 12690886
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Our experiences and indications for percutaneous cerclage of the tibia].
    Philadelphy G; Oberhammer J
    Hefte Unfallheilkd; 1974; (119):58-60. PubMed ID: 4459375
    [No Abstract]   [Full Text] [Related]  

  • 32. [Epiphyseal fixation with an external fixator. Biomechanical and clinical study].
    Lortat-Jacob A; Mazel C; Frank A; Beaufils P; Lavaste F; Mekarnia M
    Rev Chir Orthop Reparatrice Appar Mot; 1984; 70(3):207-17. PubMed ID: 6234620
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Treatment of closed fractures of the tibia].
    Okhotskiĭ VP; Potapov VI
    Sov Med; 1981; (10):106-8. PubMed ID: 7313763
    [No Abstract]   [Full Text] [Related]  

  • 34. Fibular transport in conjunction with Hoffman external fixation of the tibia.
    Ebraheim NA; DeTroye RJ; Jackson WT
    Orthop Rev; 1993 Mar; 22(3):393-5. PubMed ID: 8474779
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Minimal internal and external fixation in the treatment of open tibial fractures.
    Spiegel PG; VanderSchilden JL
    Clin Orthop Relat Res; 1983 Sep; (178):96-102. PubMed ID: 6883873
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Tibial external fixation, weight bearing, and fracture movement.
    Kershaw CJ; Cunningham JL; Kenwright J
    Clin Orthop Relat Res; 1993 Aug; (293):28-36. PubMed ID: 8339493
    [TBL] [Abstract][Full Text] [Related]  

  • 37. "Shear movement at the fracture site delays healing in a diaphyseal fracture model" by Peter Augat, Johannes Buger, Sandra Schorlemmer, Thomas Henke, Manfred Peraus, Lutz Claes [J Orthop Res 2003;21:1011-17].
    Park SH
    J Orthop Res; 2004 Sep; 22(5):1156-7; author reply 1158-9. PubMed ID: 15304293
    [No Abstract]   [Full Text] [Related]  

  • 38. Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN).
    Hansen M; Mehler D; Hessmann MH; Blum J; Rommens PM
    J Orthop Trauma; 2007; 21(10):701-9. PubMed ID: 17986887
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Hybrid external fixation of distal tibial fractures: new strategy to place pins and wires without penetrating the anterior compartment.
    Oh JK; Lee JJ; Jung DY; Kim BJ; Oh CW
    Arch Orthop Trauma Surg; 2004 Oct; 124(8):542-6. PubMed ID: 15340748
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The problem of refracture of the tibia.
    Chrisman OD; Snook GA
    Clin Orthop Relat Res; 1968; 60():217-9. PubMed ID: 5703294
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.