113 related articles for article (PubMed ID: 4444483)
1. [Reduction of primary filling volume capacity of the apparatus for artificial circulation, type AIK-5M]. Balabin EE; Kasulin VS Med Tekh; 1974; (6):27-9. PubMed ID: 4444483 [No Abstract] [Full Text] [Related]
2. [Sterilization of the pumping units of the apparatus for artificial circulation AIK-5 and AIK-5M]. Davydkin AF; Denisenko VV; Verzin SS; Kostenko AI; Mandrovnyĭ SV Med Tekh; 1976; (2):46-7. PubMed ID: 1030762 [TBL] [Abstract][Full Text] [Related]
3. [Artificial circulation method in operations on the liver]. Shapkin VS; Malyshev AF Vestn Khir Im I I Grek; 1979 Oct; 123(10):23-7. PubMed ID: 505796 [TBL] [Abstract][Full Text] [Related]
4. [Regulation of gas metabolism in the oxygenators of artificial circulation apparatus]. Fridman VE; Osipov VP Med Tekh; 1972; 5():9-15. PubMed ID: 4663472 [No Abstract] [Full Text] [Related]
8. [Evaluation of the efficiency and capacity of the bubble oxygenator]. de Magalhães HP Arq Bras Cardiol; 1979 Aug; 33(2):100-5. PubMed ID: 539919 [No Abstract] [Full Text] [Related]
9. [Comparison of capacities of bubble-oxygenators]. Matsukura H; Takeda H; Sakuma M; Takahashi J; Kawakami T Rinsho Kyobu Geka; 1982; 2(3):397-401. PubMed ID: 7156746 [No Abstract] [Full Text] [Related]
10. [Elaboration of the structure and principles of construction of a unified system for the apparatus for artificial circulation]. Khrenov VP; Rasovskiĭ SB; Podoliak MS; Osipov VP; Pisarevskiĭ AA Med Tekh; 1976; (4):13-9. PubMed ID: 1025435 [TBL] [Abstract][Full Text] [Related]
11. Extrapulmonary respiration: a review. Awad JA Can J Surg; 1974 Jan; 17(1):3-15. PubMed ID: 4590793 [No Abstract] [Full Text] [Related]
12. [Survival of a calf with an artificial heart]. Shumakov VI; Shtengol'd ESh; Gus'kov IA; Itkin GP; Movsesov RV Khirurgiia (Mosk); 1979 Aug; (8):82-6. PubMed ID: 502286 [No Abstract] [Full Text] [Related]
13. [Experimental studies on liver blood supply in extracorporeal circulation]. Hoffmeister HE; Stuntkat R; Pommer U Z Exp Chir; 1972; 5(3):177-83. PubMed ID: 4680979 [No Abstract] [Full Text] [Related]
14. [Extracorporeal circulation and its physiopathology. The pumps and their development]. Vadot M Ann Anesthesiol Fr; 1976; 17(12):1301-5. PubMed ID: 16517 [No Abstract] [Full Text] [Related]
15. [Clinical experience with voluven solution used as a basic component for pump oxygenator filling during operations on the cardiac valves and coronary arteries]. Bakanov AIu; Samsonova NN; Akimov IV; Naĭmushin AV; Kadyshkina EB Anesteziol Reanimatol; 2006; (3):41-5. PubMed ID: 16889212 [TBL] [Abstract][Full Text] [Related]
16. [The Brazilian disposable bubble oxygenator. 5000 operations with the DMG model]. Cunha MA; Santos GS; Moraes DJ; Feitosa LA; Abilio FM; Aragão E; Cisne E; Freitas E; Camargo M; Brito JD; Debiase H Arq Bras Cardiol; 1980 Oct; 35(4):283-6. PubMed ID: 7213108 [No Abstract] [Full Text] [Related]
17. [Effect of the site of applying a microfilter in an artificial circulation apparatus hook-up on changes in the formed elements of the blood]. Soboleva ER; Ishmukhametova DN Anesteziol Reanimatol; 1980; (3):66-7. PubMed ID: 7406237 [No Abstract] [Full Text] [Related]
18. Comparison of gaseous transfers through synthetic membranes for oxygenators. Lautier A; Rey P; Bizot J; Faure A; Sausse A; Laurent D Trans Am Soc Artif Intern Organs; 1969; 15():144-50. PubMed ID: 5791379 [No Abstract] [Full Text] [Related]