These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 4450627)

  • 1. [Method for the preparation of reproducible carbon- and platinum steam-layer-strengths on electron microscopy grid slides].
    Grupe M
    Z Med Labortech; 1974; 15(5):296-301. PubMed ID: 4450627
    [No Abstract]   [Full Text] [Related]  

  • 2. A universal metal and carbon evaporation accessory for electron microscopy techniques and a method for obtaining repeatable evaporations of platinum carbon.
    Harris WJ
    J Microsc; 1975 Dec; 105(3):265-7. PubMed ID: 1243766
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel method for transfer of two-dimensional crystals from the air/water interface to specimen grids. EM sample preparation/lipid-layer crystallization.
    Asturias FJ; Kornberg RD
    J Struct Biol; 1995; 114(1):60-6. PubMed ID: 7772418
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaporated germanium films as supports for microanalysis of carbon and silicon containing specimens.
    Johansen BV; Ormstad H
    Microsc Res Tech; 1997 Sep; 38(5):519-24. PubMed ID: 9376656
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transmission electron microscopy studies of the nanoscale structure and chemistry of Pt50Ru50 electrocatalysts.
    Stroud RM; Long JW; Swider-Lyons KE; Rolison DR
    Microsc Microanal; 2002 Feb; 8(1):50-7. PubMed ID: 12533204
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Method of platinum-carbon coating of ultrathin sections for transmission and scanning electron microscopy: an application for study of biological composites.
    Schwarz H; Gorb S
    Microsc Res Tech; 2003 Oct; 62(3):218-24. PubMed ID: 14506687
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Holey carbon micro-arrays for transmission electron microscopy: a microcontact printing approach.
    Chester DW; Klemic JF; Stern E; Sigworth FJ; Klemic KG
    Ultramicroscopy; 2007 Aug; 107(8):685-91. PubMed ID: 17331648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Carbon supporting films for high resolution electron microscopy--improvement of quality and preparation technique (author's transl)].
    Kölbel HK
    Mikroskopie; 1976 May; 32(1-2):1-16. PubMed ID: 972718
    [No Abstract]   [Full Text] [Related]  

  • 9. A new method of preparation of a self-perforated micro plastic grid and its application.
    Fukami A; Adachi K
    J Electron Microsc (Tokyo); 1965; 14(2):112-8. PubMed ID: 5852585
    [No Abstract]   [Full Text] [Related]  

  • 10. Construction of a cooling and heating substrate holder for the preparation of thin films for electron microscopy.
    Ott P; Günter JR
    Microsc Res Tech; 1999 Apr; 45(2):132-3. PubMed ID: 10332731
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved procedures for electron microscopic visualization of the cytoskeleton of cultured cells.
    Svitkina TM; Verkhovsky AB; Borisy GG
    J Struct Biol; 1995; 115(3):290-303. PubMed ID: 8573471
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Correlated confocal and intermediate voltage electron microscopy imaging of the same cells using sequential fluorescence labeling, fixation, and critical point dehydration.
    Peachey LD; Ishikawa H; Murakami T
    Scanning Microsc Suppl; 1996; 10():237-45; discussion 245-7. PubMed ID: 9601543
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved specimen preparation for cryo-electron microscopy using a symmetric carbon sandwich technique.
    Gyobu N; Tani K; Hiroaki Y; Kamegawa A; Mitsuoka K; Fujiyoshi Y
    J Struct Biol; 2004 Jun; 146(3):325-33. PubMed ID: 15099574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlated light and electron microscopy of the cytoskeleton.
    Auinger S; Small JV
    Methods Cell Biol; 2008; 88():257-72. PubMed ID: 18617038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noncovalent functionalization of DNA-wrapped single-walled carbon nanotubes with platinum-based DNA cross-linkers.
    Ostojic GN; Ireland JR; Hersam MC
    Langmuir; 2008 Sep; 24(17):9784-9. PubMed ID: 18646876
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Method of cleaning the surface of the specimen support grids used for electron microscopy].
    Khokhlov SE
    Tsitologiia; 1979 Oct; 21(10):1229-30. PubMed ID: 505574
    [No Abstract]   [Full Text] [Related]  

  • 18. Plan view TEM sample preparation for non-continuous and delaminating thin films.
    Weaver L
    Microsc Res Tech; 1997 Mar; 36(5):378-9. PubMed ID: 9140938
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electron holography study for two-dimensional dopant profile measurement with specimens prepared by backside ion milling.
    Yoo JH; Yang JM; Ulugbek S; Ahn CW; Hwang WJ; Park JK; Park CM; Hong SB; Kim JJ; Shindo D
    J Electron Microsc (Tokyo); 2008 Jan; 57(1):13-8. PubMed ID: 18175780
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An improved holey carbon film for cryo-electron microscopy.
    Quispe J; Damiano J; Mick SE; Nackashi DP; Fellmann D; Ajero TG; Carragher B; Potter CS
    Microsc Microanal; 2007 Oct; 13(5):365-71. PubMed ID: 17900388
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.