These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 445430)

  • 21. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom.
    Gellermann J; Wlodarczyk W; Ganter H; Nadobny J; Fähling H; Seebass M; Felix R; Wust P
    Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):267-77. PubMed ID: 15629620
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm.
    Davidson SR; Vitkin IA; Sherar MD; Whelan WM
    Lasers Surg Med; 2005 Apr; 36(4):297-306. PubMed ID: 15786482
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Artefacts in intracavitary temperature measurements during regional hyperthermia.
    Kok HP; Van den Berg CA; Van Haaren PM; Crezee J
    Phys Med Biol; 2007 Sep; 52(17):5157-71. PubMed ID: 17762078
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Absence of radiofrequency heating from auditory implants during magnetic resonance imaging.
    Chou CK; McDougall JA; Can KW
    Bioelectromagnetics; 1995; 16(5):307-16. PubMed ID: 8554632
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimal power deposition patterns for ideal high temperature therapy/hyperthermia treatments.
    Cheng KS; Roemer RB
    Int J Hyperthermia; 2004 Feb; 20(1):57-72. PubMed ID: 14612314
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Direct temperature measurement.
    Fessenden P; Lee ER; Samulski TV
    Cancer Res; 1984 Oct; 44(10 Suppl):4799s-4804s. PubMed ID: 6467232
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optimization of electromagnetic phased-arrays for hyperthermia via magnetic resonance temperature estimation.
    Kowalski ME; Behnia B; Webb AG; Jin JM
    IEEE Trans Biomed Eng; 2002 Nov; 49(11):1229-41. PubMed ID: 12450353
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Clinical instrumentation requirements with a review of the Perth hyperthermia experience.
    Caldwell WL
    Cancer Res; 1979 Jun; 39(6 Pt 2):2332-5. PubMed ID: 109192
    [No Abstract]   [Full Text] [Related]  

  • 29. A simple method for accurate temperature measurement.
    Grucza R; Boruta E
    Acta Physiol Pol; 1980; 31(4):449-52. PubMed ID: 7446155
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The design of an optical fiber pressure transducer for use in the upper airways.
    Goodyer PD; Fothergill JC; Jones NB; Hanning CD
    IEEE Trans Biomed Eng; 1996 Jun; 43(6):600-6. PubMed ID: 8987264
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Thermal ablation and high-temperature thermal therapy: overview of technology and clinical implementation.
    Diederich CJ
    Int J Hyperthermia; 2005 Dec; 21(8):745-53. PubMed ID: 16338857
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [New electronic methods for clinical measurement of temperature].
    Jensen O
    Tidsskr Nor Laegeforen; 1992 Dec; 112(30):3815-7. PubMed ID: 1485299
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ultrasound velocimetry for hyperthermia control.
    Robert J; Marchal C; Drocourt M; Escanye JM; Thouvenot P; Gaulard ML; Tosser A
    Prog Clin Biol Res; 1982; 107():555-60. PubMed ID: 7167507
    [No Abstract]   [Full Text] [Related]  

  • 34. Fiber-optic microsensors for simultaneous sensing of oxygen and pH, and of oxygen and temperature.
    Kocincova AS; Borisov SM; Krause C; Wolfbeis OS
    Anal Chem; 2007 Nov; 79(22):8486-93. PubMed ID: 17948966
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Validation of Noninvasive Ultrasound Temperature Measurement System Through Experiments Using Resonant Cavity Applicator.
    Shindo Y; Kato K; Ikuta F; Takahashi K
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():2521-2524. PubMed ID: 31946410
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Hyperthermia in cancer therapy].
    Mochizuki A; Saito M
    Iyodenshi To Seitai Kogaku; 1982 Apr; 20(2):65-72. PubMed ID: 6752498
    [No Abstract]   [Full Text] [Related]  

  • 37. Electrical impedance tomography: prospects for non-invasive control of deep hyperthermia treatments.
    Hawley MS; Conway J; Amasha H; Mangnall YF; van Rhoon GC
    Front Med Biol Eng; 1992; 4(2):119-28. PubMed ID: 1510884
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fiber optics in medicine.
    Epstein M
    Crit Rev Biomed Eng; 1982 Feb; 7(2):79-120. PubMed ID: 7047073
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [The Optoterm fiberoptic system for temperature measurement in interstitial UHF-hyperthermia].
    Kurpeshev OK; Menteshashvili GZ; Konopliannikov AG; Seliutin VP; Cherepanov TIa
    Med Radiol (Mosk); 1987 May; 32(5):71-3. PubMed ID: 3586930
    [No Abstract]   [Full Text] [Related]  

  • 40. Thermal dosimetry and clinical requirements.
    Luk KH; Phillips TL
    Cancer Res; 1979 Jun; 39(6 Pt 2):2300-3. PubMed ID: 445427
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]