These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 4515491)

  • 1. Corrosion of metal fracture fixation appliances.
    Byrne JE; Lovasko JH; Laskin DM
    J Oral Surg; 1973 Aug; 31(8):639-45. PubMed ID: 4515491
    [No Abstract]   [Full Text] [Related]  

  • 2. [Corrosion of the matallic constructions and matallosis of the tissues in the treatment of bone fractures].
    Gritsanov AI; Stanchits IuF
    Vestn Khir Im I I Grek; 1977 Feb; 118(2):105-10. PubMed ID: 857388
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Failures of surgical implants caused by corrosion of a combination of mechanical stresses and corrosion (author's transl)].
    Fäbber K; Sinn R; Spähn H
    Biomed Tech (Berl); 1973 Oct; 18(5):176-83. PubMed ID: 4800699
    [No Abstract]   [Full Text] [Related]  

  • 4. Complications associated with rigid internal fixation of mandibular fractures.
    Ahulubalia TP; Lata J; Gumber TK
    Indian J Dent Res; 2003; 14(2):81-5. PubMed ID: 14705451
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Current problems on the opportune time for the early removal of metal osteosynthesis appliances. Biological and clinical aspects. Painful osteosynthesis].
    Aulisa L; Tranquilli Leali P; Lorini G
    Arch Putti Chir Organi Mov; 1978; 29():325-31. PubMed ID: 757486
    [No Abstract]   [Full Text] [Related]  

  • 6. Mandibular fractures treated by bone plating and intraosseous wiring. A comparative study.
    Zachariades N; Papademetriou I; Rallis G
    Rev Stomatol Chir Maxillofac; 1994; 95(5):386-90. PubMed ID: 7984963
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Lag screw fixation of mandibular fractures.
    Ellis E
    J Craniomaxillofac Trauma; 1997; 3(1):16-26. PubMed ID: 11951267
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Complications of miniplate osteosynthesis in the treatment of mandibular fractures.
    Peled M; Ardekian L; Abu-el-Naaj I; Rahmiel A; Laufer D
    J Craniomaxillofac Trauma; 1997; 3(2):14-7. PubMed ID: 11951412
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CROOMA, complication rates of operatively treated mandibular fractures, paramedian and body.
    Seemann R; Lauer G; Poeschl PW; Schicho K; Pirklbauer M; Russmüller G; Krennmair G; Perisanidis C; Ewers R; Klug C
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Apr; 111(4):449-54. PubMed ID: 20952223
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective trial of poly-L-lactic/polyglycolic acid co-polymer plates and screws for internal fixation of mandibular fractures.
    Ferretti C
    Int J Oral Maxillofac Surg; 2008 Mar; 37(3):242-8. PubMed ID: 18295449
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Hazards of metallosis from ostheosynthesis materials].
    Grasser HH
    Dtsch Zahnarztl Z; 1972 May; 27(5):413-22. PubMed ID: 4503076
    [No Abstract]   [Full Text] [Related]  

  • 12. Complications of rigid internal fixation for mandibular fractures.
    Ellis E
    J Craniomaxillofac Trauma; 1996; 2(2):32-9. PubMed ID: 11951481
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Scanning electron microscopic studies on the corrosion behavior of osteosynthesis plates made of titanium and V4A steel. A case report].
    Bienengräber V; Härtel J; Godknecht K
    Dtsch Zahn Mund Kieferheilkd Zentralbl; 1991; 79(1):35-6. PubMed ID: 9272989
    [No Abstract]   [Full Text] [Related]  

  • 14. Invited review: small versus large plate fixation of mandibular fractures.
    Alpert B; Engelstad M; Kushner GM
    J Craniomaxillofac Trauma; 1999; 5(3):33-9; discussion 40. PubMed ID: 11951257
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Surface damage due to corrosion in living tissue, particularly in bone, studied with the scanning electron microscope].
    Münzenberg KJ; Flajs G; Roggatz J; Süssenbach F
    Z Orthop Ihre Grenzgeb; 1972 Jun; 110(3):336-41. PubMed ID: 4263217
    [No Abstract]   [Full Text] [Related]  

  • 16. The need for rigid fixation of combined parasymphyseal and bilateral subcondylar fractures.
    Wheatley MJ; Meltzer TR
    J Craniomaxillofac Trauma; 1997; 3(1):46-51. PubMed ID: 11951271
    [TBL] [Abstract][Full Text] [Related]  

  • 17. One miniplate versus two in the management of mandibular angle fractures: a prospective randomised study.
    Siddiqui A; Markose G; Moos KF; McMahon J; Ayoub AF
    Br J Oral Maxillofac Surg; 2007 Apr; 45(3):223-5. PubMed ID: 17110006
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Infections associated with locking reconstruction plates: a retrospective review.
    Kirkpatrick D; Gandhi R; Van Sickels JE
    J Oral Maxillofac Surg; 2003 Apr; 61(4):462-6. PubMed ID: 12684964
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Results of mandibular osteosynthesis with miniaturized screwed plates. Apropos of 800 fractures treated over a 10-year period].
    Khouri M; Champy M
    Ann Chir Plast Esthet; 1987; 32(3):262-6. PubMed ID: 2445246
    [No Abstract]   [Full Text] [Related]  

  • 20. [Prevention of postoperative damage by intra- or extraoral approach to mandibular fractures].
    Hoffmeister B; Härle F
    Fortschr Kiefer Gesichtschir; 1985; 30():112-6. PubMed ID: 3861503
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.