92 related articles for article (PubMed ID: 452050)
1. [An analytical method to calculate electron dose distributions. Part I: Method (author's transl)].
Fehrentz D; Kimmig B; Ihnen E; Schröder-Babo P
Strahlentherapie; 1979 Apr; 155(4):248-53. PubMed ID: 452050
[TBL] [Abstract][Full Text] [Related]
2. [An analytical method for calculation of electron dose distributions. Part II: Experimental verification and application in coplanar irradiation techniques (author's transl)].
Kimmig B; Fehrentz D; Ihnen E; Marzinko H
Strahlentherapie; 1979 May; 155(5):316-27. PubMed ID: 108816
[TBL] [Abstract][Full Text] [Related]
3. Absorbed dose distributions for X-ray beams and beams of electrons from the Therac 20 Saturne linear accelerator.
Tronc D; Noël A
Strahlentherapie; 1978 Nov; 154(11):780-5. PubMed ID: 715810
[TBL] [Abstract][Full Text] [Related]
4. [Measurement on a 42-meV betatron with regard to the radiological protection of patients (author's transl)].
Hassenstein E; Nüsslin F
Strahlentherapie; 1979 Jan; 155(1):15-9. PubMed ID: 760270
[TBL] [Abstract][Full Text] [Related]
5. [Neutron pollution in roentgen beams from electron accelerators].
Fehrentz D; Hassib GM; Spyropoulos B
Strahlentherapie; 1983 Nov; 159(11):703-12. PubMed ID: 6658859
[TBL] [Abstract][Full Text] [Related]
6. [Changes of the depth dose curve in case of 42 MeV photon irradiation through a plexiglass plate of 3 cm (author's transl)].
Ihnen E
Strahlentherapie; 1978 Jul; 154(7):479-81. PubMed ID: 97805
[TBL] [Abstract][Full Text] [Related]
7. Calculation of high-energy electron dose distributions in tissue-equivalent media. I. Determination of the dose function of point unidirectional sources.
Kozlov AP; Shishov VA
Strahlentherapie; 1982 May; 158(5):298-304. PubMed ID: 7112625
[TBL] [Abstract][Full Text] [Related]
8. Absorbed dose distribution for X-ray beams and beams of electrons from the Therac 10 Neptune linear accelerator.
Tronc D; Gayet P
Strahlentherapie; 1980 Feb; 156(2):125-8. PubMed ID: 7355413
[TBL] [Abstract][Full Text] [Related]
9. [Contribution to deep electron pendulous therapy. VIII. Communication: concerning the problem of diverging contours in telecentric electron pendulous irradiation using the electron energies 10 MeV and 20 MeV (author's transl)].
Krause K; Hüdepohl G; Fees H; Rassow J
Strahlentherapie; 1978 Jan; 154(1):29-37. PubMed ID: 415385
[TBL] [Abstract][Full Text] [Related]
10. [Consideration of inhomogeneities in irradiation planning. 3. Influence of inhomogeneities on the shape of the depth dose curve in water with electronic radiation of different energies (author's transl)].
Zwicker H; Felix R
Strahlentherapie; 1977 Feb; 153(2):86-94. PubMed ID: 402714
[TBL] [Abstract][Full Text] [Related]
11. Comparison between experimental measurements and calculated transport simulation for electron dose distributions inside homogeneous phantoms.
Borrell-Carbonell A; Patau JP; Terrissol M; Tronc D
Strahlentherapie; 1980 Mar; 156(3):186-91. PubMed ID: 7361334
[TBL] [Abstract][Full Text] [Related]
12. [Calculation of the dose distribution for ultrahard X-ray bremsstrahlung].
Leetz HK; Lesmeister F
Strahlenther Onkol; 1986 Mar; 162(3):171-8. PubMed ID: 3961674
[TBL] [Abstract][Full Text] [Related]
13. [Calculation of the dose for fast electrons using a matrix algorithm (author's transl)].
Leetz HK
Strahlentherapie; 1979 Mar; 155(3):181-7. PubMed ID: 107619
[TBL] [Abstract][Full Text] [Related]
14. [Calculation of the dose distribution of high-energy electrons within and behind tissue inhomogeneities of any width. II. Influence of multiple scattering (author's transl)].
Mandour MA; Harder D
Strahlentherapie; 1978 Aug; 154(8):546-53. PubMed ID: 98866
[TBL] [Abstract][Full Text] [Related]
15. [Analytical description of the dose fields from accelerated electrons].
Kozlov VA; Denisenko ON
Med Radiol (Mosk); 1983 Mar; 28(3):56-7. PubMed ID: 6835059
[TBL] [Abstract][Full Text] [Related]
16. [Study on the dose distribution of 8-MeV bremsstrahlung in mantle field techniques (author's transl)].
Nemec HW; Walther E
Strahlentherapie; 1979 Aug; 155(8):557-61. PubMed ID: 473255
[TBL] [Abstract][Full Text] [Related]
17. Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy.
Chen Z; Agostinelli AG; Wilson LD; Nath R
Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):872-85. PubMed ID: 15183491
[TBL] [Abstract][Full Text] [Related]
18. [A Cerenkov detector to determine the energy in electron accelerators (author's transl)].
Martens H; Seeger W
Strahlentherapie; 1980; 156(10):697-702. PubMed ID: 7434376
[TBL] [Abstract][Full Text] [Related]
19. [Distribution of absorbed dose of electron beams from a linear accelerator of 8-17.5 MeV energy].
Kozlov AP; Afanas'ev BP; Ershov AT; Likhtarev MI; Regel' AV
Med Radiol (Mosk); 1987 Apr; 32(4):65-71. PubMed ID: 3586912
[TBL] [Abstract][Full Text] [Related]
20. [An empirical model for calculating electron dose distributions].
Leistner H; Schüler W
Radiobiol Radiother (Berl); 1990; 31(2):143-50. PubMed ID: 2356295
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]