86 related articles for article (PubMed ID: 453959)
1. Myocardial stimulation impedance: the effects of electrode, physiological, and stimulus variables. Tyers GF; Brownlee RR; Hughes HC; Shaffer CW; Williams EH; Kao RL Ann Thorac Surg; 1979 Jan; 27(1):63-9. PubMed ID: 453959 [TBL] [Abstract][Full Text] [Related]
2. Effect of stimulation site on ventricular threshold in dogs with heart block. Hughes HC; Tyers GF Am Heart J; 1975 Jan; 89(1):68-73. PubMed ID: 1109554 [TBL] [Abstract][Full Text] [Related]
3. A fractally coated, 1.3 mm2 high impedance pacing electrode. Fröhlig G; Bolz A; Ströbel J; Rutz M; Lawall P; Schwerdt H; Schaldach M; Schieffer H Pacing Clin Electrophysiol; 1998 Jun; 21(6):1239-46. PubMed ID: 9633066 [TBL] [Abstract][Full Text] [Related]
4. [Stable stimulation impedance of steroid electrodes in various impulse amplitudes: indications for low polarization of the electrode-myocardium interface]. Schuchert A; Kuck KH Z Kardiol; 1993 Jan; 82(1):41-5. PubMed ID: 8470419 [TBL] [Abstract][Full Text] [Related]
5. Failure of demand pacing with small surface area electrodes. Hughes HC; Brownlee RR; Tyers GF Circulation; 1976 Jul; 54(1):128-32. PubMed ID: 1277416 [TBL] [Abstract][Full Text] [Related]
6. Benefits of smaller electrode surface area (4 mm2) on steroid-eluting leads. Schuchert A; Kuck KH Pacing Clin Electrophysiol; 1991 Dec; 14(12):2098-104. PubMed ID: 1723192 [TBL] [Abstract][Full Text] [Related]
7. Paradigm shift in lead design. Irnich W Pacing Clin Electrophysiol; 1999 Sep; 22(9):1321-32. PubMed ID: 10527013 [TBL] [Abstract][Full Text] [Related]
8. The advantages of transthoracic placement of permanent cardiac pacemaker electrodes. Tyers GF; Hughes HC; Torman HA; Waldhausen JA J Thorac Cardiovasc Surg; 1975 Jan; 69(1):8-16. PubMed ID: 1110578 [TBL] [Abstract][Full Text] [Related]
9. Effects of local steroid elution on chronic pacing threshold and impedance of endocardial pacemaker leads. Schuchert A; Kuck KH Cardiology; 1993; 83(4):240-3. PubMed ID: 8281540 [TBL] [Abstract][Full Text] [Related]
10. [Local steroid elution via pacemaker electrodes: improved stimulation and sensing functions]. Schuchert A; Kuck KH Dtsch Med Wochenschr; 1992 Apr; 117(16):607-12. PubMed ID: 1568427 [TBL] [Abstract][Full Text] [Related]
11. The interdependence between electrogram, total electrode impedance and pacemaker input impedance necessary to obtain adequate functioning of demand pacemakers. Ohm OJ Pacing Clin Electrophysiol; 1979 Jul; 2(4):465-85. PubMed ID: 95316 [TBL] [Abstract][Full Text] [Related]
12. [Electrode surface areas, pulse duration and stimulation threshold. Acute and chronic study with endocardial unipolar electrodes (author's transl)]. Antonioli GE; Grassi G; Baggioni GF; Bagni B G Ital Cardiol; 1977; 7(4):380-6. PubMed ID: 863147 [TBL] [Abstract][Full Text] [Related]
13. Effects of acid-base imbalance on myocardial pacing thresholds. Hughes JC; Tyers GF; Torman HA J Thorac Cardiovasc Surg; 1975 May; 69(5):743-6. PubMed ID: 1127972 [TBL] [Abstract][Full Text] [Related]
14. Microdislodgment: a likely mechanism of pacing failure with high impedence small area electrodes. Kikuchi K; Abe H; Nagatomo T; Nakashima Y Pacing Clin Electrophysiol; 2003 Jul; 26(7 Pt 1):1541-3. PubMed ID: 12914635 [TBL] [Abstract][Full Text] [Related]