These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
112 related articles for article (PubMed ID: 4561303)
1. Calculation methods and model experiments for the determination of the parameters of third (peripheral) mixing chambers using the isotope dilution technique. Ludt H; Herrmann HD Res Exp Med (Berl); 1972; 158(2):95-122. PubMed ID: 4561303 [No Abstract] [Full Text] [Related]
2. [Standardization of the isotope dilution technic for chromium determination, using Cr-51]. Marino DA Rev Farm Bioquim Univ Sao Paulo; 1976; 14(2):173-93. PubMed ID: 801188 [TBL] [Abstract][Full Text] [Related]
3. [A method of electric simulation of the radionuclide dilution curve]. Gavriliuk VP; Tishchenko FM Med Tekh; 1992; (2):21-4. PubMed ID: 1513235 [TBL] [Abstract][Full Text] [Related]
4. Analogue model for the analysis of radiocardiograms. Heiskanen T Cardiovasc Res; 1971 Jul; 5(3):268-76. PubMed ID: 4934295 [No Abstract] [Full Text] [Related]
6. The validity of the isotope dilution method of measuring extracellular fluid volume after acute haemorrhage. Furneaux RW; Tracy GD Aust J Exp Biol Med Sci; 1970 Aug; 48(4):407-15. PubMed ID: 4919310 [No Abstract] [Full Text] [Related]
7. A method for computing frequency functions from input-output vascular dilution curves. Pollastri A; Pistolesi M; Giuntini C J Nucl Med Allied Sci; 1977; 21(4):165-72. PubMed ID: 342678 [No Abstract] [Full Text] [Related]
8. Use of isotope dilution--mass spectrometry for accuracy control of different routine methods used in clinical chemistry. Björkhem I; Blomstrand R; Eriksson S; Falk O; Kallner A; Svensson L; Ohman G Scand J Clin Lab Invest; 1980 Oct; 40(6):529-34. PubMed ID: 7003693 [TBL] [Abstract][Full Text] [Related]
9. [Modeling of hemodynamic processes and indirect determination of the circulation blood volume and blood components]. Sidora VD; Kovalev VP Med Radiol (Mosk); 1978 May; 23(5):41-7. PubMed ID: 353428 [No Abstract] [Full Text] [Related]
10. Digital computer aids for the cardiac output calculation from radio isotope dilution curves. UEDA H; IIO M; NAKANISHI A; KOIDE T Jpn Heart J; 1962 Jan; 3():24-33. PubMed ID: 13923463 [No Abstract] [Full Text] [Related]
11. Blood transport in pulmonary circulation simulated by a digital computer. Paiva M; Adam WE J Nucl Biol Med; 1974; 18(1):1-12. PubMed ID: 4600274 [No Abstract] [Full Text] [Related]
12. Effects of insulin on glucose turnover rates in vivo: isotope dilution versus constant specific activity technique. Hother-Nielsen O; Henriksen JE; Holst JJ; Beck-Nielsen H Metabolism; 1996 Jan; 45(1):82-91. PubMed ID: 8544782 [TBL] [Abstract][Full Text] [Related]
13. Measurement of relative blood flow, transit-time distributions and transport-model parameters by residue detection when radiotracer recirculates. Larson KB; Snyder DL J Theor Biol; 1972 Dec; 37(3):503-29. PubMed ID: 4566635 [No Abstract] [Full Text] [Related]
14. [Determination of the hemodynamic parameters of patients with an arteriovenous fistula by using a mathematical model based on radiocardiographic data]. Malov GA; Matveeva AI; Sakharov MP; Shlain VA Med Radiol (Mosk); 1979 Oct; 24(10):27-32. PubMed ID: 388136 [No Abstract] [Full Text] [Related]
15. Procedure for determination of aldosterone in human peripheral plasma by double-isotope derivative assay, and its application for measurement of secretory rate and urinary excretion. Nowaczynski W; Silah J; Genest J Can J Biochem; 1967 Dec; 45(12):1919-36. PubMed ID: 4295532 [No Abstract] [Full Text] [Related]
16. Dynamics of tissue distribution of radiopotassium as affected by simulated differences in regional extraction. Downey HF; Bashour FA Cardiovasc Res; 1975 Sep; 9(5):607-12. PubMed ID: 1104175 [TBL] [Abstract][Full Text] [Related]
17. [Automatic analysis of radiocardiogram using a minicomputer (author's transl)]. Minato K; Kuwahara M; Yonekura Y; Ishii Y; Hirakawa A Iyodenshi To Seitai Kogaku; 1978 Apr; 16(2):95-102. PubMed ID: 357793 [No Abstract] [Full Text] [Related]
19. A rapid radioisotope dilution technique for the accurate determination of the cardiac output. Razzak MA; Botti RE; MacIntyre WJ Nucl Med (Stuttg); 1968; 7(1):1-7. PubMed ID: 4880052 [No Abstract] [Full Text] [Related]
20. Assessment of cardiac blood pools in radiocardiography by various indicator dilution models. Olkkonen H; Penttilä IM Nuklearmedizin; 1977 Jul; 16(3):96-9. PubMed ID: 331270 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]