These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 4561579)

  • 1. Predicting the extent of viability in flaps by measurement of gas tensions, using a mass spectrometer.
    Guthrie RH; Goulian D; Cucin RL
    Plast Reconstr Surg; 1972 Oct; 50(4):385-9. PubMed ID: 4561579
    [No Abstract]   [Full Text] [Related]  

  • 2. Timing of pedicle flap delays by measurements of flap oxygen and carbon dioxide.
    Reisin JH; Guthrie RH; Goulian D
    J Surg Oncol; 1974; 6(1):79-85. PubMed ID: 4594631
    [No Abstract]   [Full Text] [Related]  

  • 3. Continuous, simultaneous and instantaneous tissue gas and blood flow measurements using the mass spectrometer.
    Owens G; Roberts M
    J Surg Oncol; 1972; 4(4):363-8. PubMed ID: 5083570
    [No Abstract]   [Full Text] [Related]  

  • 4. On-line O2 and CO2 analysis in vivo.
    Kleiman BS; Brantigan O; Zapata A
    J Assoc Adv Med Instrum; 1971; 5(4):224-6. PubMed ID: 5118804
    [No Abstract]   [Full Text] [Related]  

  • 5. Intramyocardial gas tensions in the human heart during coronary artery-saphenous vein bypass.
    Gardner TJ; Brantigan JW; Perna AM; Bender HW; Brawley RK; Gott VL
    J Thorac Cardiovasc Surg; 1971 Dec; 62(6):844-50. PubMed ID: 5129388
    [No Abstract]   [Full Text] [Related]  

  • 6. The measurement of myocardial tissue gas tensions by mass spectrometry.
    Wilson GJ; MacGregor DC
    Crit Care Med; 1976; 4(5):248-54. PubMed ID: 975851
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Possibilities for the use of a gas-mass-spectrometer (varian MAT M3) in anaesthesia].
    Schöning L; Kolb E
    Anaesthesist; 1972 Jul; 21(7):318-21. PubMed ID: 4341423
    [No Abstract]   [Full Text] [Related]  

  • 8. On-line in vivo measurements of partial pressures of oxygen and carbon dioxide of blood, tissue, and respired air by mass spectrometry.
    Dardik H; Dardik I; Laufman H
    Surg Gynecol Obstet; 1970 Dec; 131(6):1157-60. PubMed ID: 5479214
    [No Abstract]   [Full Text] [Related]  

  • 9. A method for the in vitro measurement of tensions of blood gases with a mass spectrometer.
    Matalon S; Erickson J; Mosharrafa M; Leonard AS
    Med Instrum; 1975; 9(3):133-5. PubMed ID: 1128321
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new small diameter mass spectrometer cannula for medical use.
    Roberts M; Thomas DD; Owens G; Vilinskas J; O'Rourke J
    Med Res Eng; 1972; 11(3):27-8. PubMed ID: 4198547
    [No Abstract]   [Full Text] [Related]  

  • 11. Mass spectrometry for the measurement of intramyocardial gas tensions: methodology and application to the study of myocardial ischemia.
    Khuri SF; O'Riordan J; Flaherty JT; Brawley RK; Donahoo JS; Gott VL
    Recent Adv Stud Cardiac Struct Metab; 1975; 10():539-50. PubMed ID: 1209001
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Flight research program. V. Mass spectrometer in medical monitoring.
    Roman J; Brigden WH
    Aerosp Med; 1966 Dec; 37(12):1213-7. PubMed ID: 5972718
    [No Abstract]   [Full Text] [Related]  

  • 13. Mass spectrographic quantitation of regional cerebral blood flow.
    Roberts M; Vilinskas J; Owens G
    Med Res Eng; 1972; 11(3):25-6. PubMed ID: 4665178
    [No Abstract]   [Full Text] [Related]  

  • 14. Continuous measurements of local PO2 and PCO2 during the creation of bipedicle skin flaps in dogs.
    Wilson WR; Toomey JM; Owens G
    Surg Forum; 1972; 23(0):495-7. PubMed ID: 4601102
    [No Abstract]   [Full Text] [Related]  

  • 15. Alterations in analysis of tissue gases following chronic implantation of Teflon cannulas.
    Miller SH; Duscher ML; Graham WP; Calabretta AM
    Surg Forum; 1975; 26():565-7. PubMed ID: 1216227
    [No Abstract]   [Full Text] [Related]  

  • 16. Direct mass spectrographic measurement of regional intracerebral oxygen, carbon dioxide, and argon.
    Roberts M; Owens G
    J Neurosurg; 1972 Dec; 37(6):706-10. PubMed ID: 4654700
    [No Abstract]   [Full Text] [Related]  

  • 17. [Determination of the respiratory gas concentration and of pulmonary ventilation volumes by using a mass spectrometer].
    Levshankov AI; Ozerov LN; Pushkina MA; Slutskiĭ ME; Uvarov BS
    Vestn Khir Im I I Grek; 1981 Oct; 127(10):115-7. PubMed ID: 6797124
    [No Abstract]   [Full Text] [Related]  

  • 18. Mass spectrometry for measuring changes in intramyocardial pO2 and pCO2.
    Wilson GJ; MacGregor DC; Holness DE; Lixfeld W; Yasui H
    Adv Exp Med Biol; 1973; 37A():547-52. PubMed ID: 4500068
    [No Abstract]   [Full Text] [Related]  

  • 19. [Measurement of skin conductance to gas in adults].
    Itoh S; Yamamoto K; Mikami T
    Iyodenshi To Seitai Kogaku; 1987 Sep; 25(3):227-31. PubMed ID: 3128678
    [No Abstract]   [Full Text] [Related]  

  • 20. [Water vapour independent inley systems for respiration mass spectrometers].
    Muysers K; Delgmann L; Smidt U
    Pflugers Arch Gesamte Physiol Menschen Tiere; 1968; 299(2):185-90. PubMed ID: 5247218
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.