102 related articles for article (PubMed ID: 459782)
1. [Blood heat exchangers for the artificial heart using a radioisotope power source]. Kiselev IuM; Trukhmanov SB; Mosidze TG; Kremnev VA; Ponomarenko TP Med Tekh; 1979; (3):9-13. PubMed ID: 459782 [TBL] [Abstract][Full Text] [Related]
2. Prospects for using implanted systems of assisted circulation and artificial heart with a radioisotope power source (biomedical, thermal, and radiation aspects). Kiselev IM; Dubrovskiĭ GP; Mosidze TG; Bazhanov AIu Artif Organs; 1983 Feb; 7(1):117-21. PubMed ID: 6838399 [TBL] [Abstract][Full Text] [Related]
3. [Automatic control of an artificial heart with an autonomous energy source]. Sumin AV; Sokolov AI; Itkin GP; Kremnev VA; Kiselev IuM Med Tekh; 1980; (2):44-8. PubMed ID: 7392877 [TBL] [Abstract][Full Text] [Related]
4. Heat from an implanted power source is mainly dissipated by blood perfusion. Okazaki Y; Davies CR; Matsuyoshi T; Fukamachi K; Wika KE; Harasaki H ASAIO J; 1997; 43(5):M585-8. PubMed ID: 9360112 [TBL] [Abstract][Full Text] [Related]
5. In vitro and in vivo heat dissipation of an electrohydraulic totally implantable artificial heart. Endo S; Masuzawa T; Tatsumi E; Taenaka Y; Nakatani T; Ohno T; Wakisaka Y; Nishimura T; Takewa Y; Nakamura M; Takiura K; Sohn YS; Takano H ASAIO J; 1997; 43(5):M592-7. PubMed ID: 9360114 [TBL] [Abstract][Full Text] [Related]
6. [Thermoregulating devices for artificial circulation apparatus with thermoelectric elements]. Efremov AA; Andrushchenko LI Med Tekh; 1981; (1):24-8. PubMed ID: 7207094 [TBL] [Abstract][Full Text] [Related]
7. The total artificial heart. Jarvik RK Sci Am; 1981 Jan; 244(1):74-80. PubMed ID: 7010587 [No Abstract] [Full Text] [Related]
8. An implantable power source for an artificial heart or left ventricular assist device. Spitzer D Trans Am Soc Artif Intern Organs; 1985; 31():193-5. PubMed ID: 3837443 [No Abstract] [Full Text] [Related]
9. Implanted artificial heart with radioisotope power source. Shumakov VI; Griaznov GM; Zhemchuzhnikov GN; Kiselev IM; Osipov AP Artif Organs; 1983 Feb; 7(1):101-6. PubMed ID: 6838394 [TBL] [Abstract][Full Text] [Related]
10. [Power units of implanted artificial heart and assisted circulation system]. Kiselev IuM; Kremnev VA; Sadov VV; Spiridonov VA Med Tekh; 1976; (4):50-6. PubMed ID: 1025440 [TBL] [Abstract][Full Text] [Related]
11. Heat dissipation through the blood contacting surface of a thermally driven LVAS. Navarro RR; Kiraly RJ; Harasaki H; Nasu M; Nosè Y Int J Artif Organs; 1988 Sep; 11(5):381-6. PubMed ID: 3192316 [TBL] [Abstract][Full Text] [Related]
12. [The physiologic and physical patterns of blood heat exchange with tissues and the environment]. Ivanov KP; Kulikova OV; Dymnikova LP; Rumiantsev GV Fiziol Zh SSSR Im I M Sechenova; 1989 Jun; 75(6):851-6. PubMed ID: 2806650 [TBL] [Abstract][Full Text] [Related]
13. Experiences with a sac-type artificial heart. Morris DT; Couves CM Can Med Assoc J; 1971 Sep; 105(5):483-7. PubMed ID: 5112120 [TBL] [Abstract][Full Text] [Related]
14. [Components of an implanted artificial heart and the medico-technical requirements]. Egorov TL; Kiselev IuM; Kremnev VA; Sadov VV; Spiridonov VA Med Tekh; 1976; (4):6-10. PubMed ID: 1025442 [TBL] [Abstract][Full Text] [Related]
15. An implantable nuclear fuel capsule for an artificial heart. Norman JC; Covelli VH; Bernhard WF; Spira J Trans Am Soc Artif Intern Organs; 1968; 14():204-9. PubMed ID: 5701531 [No Abstract] [Full Text] [Related]
16. Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart. Yamamoto T; Koshiji K; Homma A; Tatsumi E; Taenaka Y J Artif Organs; 2008; 11(4):238-40. PubMed ID: 19184291 [TBL] [Abstract][Full Text] [Related]
17. [Support of the blood circulation in the organism by use of an implanted artificial heart with automatic regulation]. Shumakov VI; Egorov TL; Itkin GP; Bozh'ev AA; Vinogradov VI Biull Eksp Biol Med; 1974 Dec; 78(12):3-6. PubMed ID: 4441654 [No Abstract] [Full Text] [Related]
18. Artificial heart driving systems historical review and future possibilities. Mrava GL Adv Biomed Eng Med Phys; 1970; 3():31-68. PubMed ID: 4950395 [No Abstract] [Full Text] [Related]
20. A finite element model for phase change heat transfer in a composite tissue with blood perfusion. Hayes LJ; Diller KR ISA Trans; 1983; 22(4):33-7. PubMed ID: 6662667 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]