110 related articles for article (PubMed ID: 4605316)
1. The preparation of small, particulate specimens by critical point drying: application for scanning electron microscopy.
Lung B
J Microsc; 1974 May; 101(1):77-80. PubMed ID: 4605316
[No Abstract] [Full Text] [Related]
2. Critical point drying of protozoan cells and other biological specimens for scanning electron microscopy: apparatus and methods of specimen preparation.
Ruffolo JJ
Trans Am Microsc Soc; 1974 Jan; 93(1):124-34. PubMed ID: 4204661
[No Abstract] [Full Text] [Related]
3. Scanning electron microscopy of critical point dried human spermatozoa.
Lung B; Bahr GF
J Reprod Fertil; 1972 Nov; 31(2):317-8. PubMed ID: 4564897
[No Abstract] [Full Text] [Related]
4. Critical point drying for scanning electron microscopy: a semi-automatic method of preparing biological specimens.
Hall DJ; Skerrett EJ; Thomas WD
J Microsc; 1978 Aug; 113(3):277-90. PubMed ID: 361959
[TBL] [Abstract][Full Text] [Related]
5. [Refined preparation of biological specimens for the scanning-electron-microscope].
Heinzmann U
Microsc Acta; 1974 Sep; 76(2):145-6. PubMed ID: 4614014
[No Abstract] [Full Text] [Related]
6. [A simple addition to a critical point apparatus for drying of serial sections (author's transl)].
Petzold H; Ozel M
Microsc Acta; 1976 Sep; 78(4):292-4. PubMed ID: 798115
[No Abstract] [Full Text] [Related]
7. An improved method for the scanning electron microscopy of spermatozoa.
Baccetti B; Burrini AG
J Microsc; 1973 Sep; 99(1):101-7. PubMed ID: 4201611
[No Abstract] [Full Text] [Related]
8. Preparation of mammalian gametes and reproductive tract tissues for scanning electron microscopy.
Gould KG; Vet B
Fertil Steril; 1973 Jun; 24(6):448-56. PubMed ID: 4196902
[No Abstract] [Full Text] [Related]
9. A freeze-etching study of rabbit spermatozoa with particular reference to head structures.
Koehler JK
J Ultrastruct Res; 1970 Dec; 33(5):598-614. PubMed ID: 4923167
[No Abstract] [Full Text] [Related]
10. [Critical point drying--a preparation method for scanning electron microscopy].
Fromme HG; Pfautsch M; Pfefferkorn G; Bystricky V
Microsc Acta; 1972 Nov; 73(1):29-37. PubMed ID: 4569709
[No Abstract] [Full Text] [Related]
11. [A method of preparing routine histologic specimens for examination using a scanning electron microscope and roentgenologic microanalyser].
Grzybek H; Tomczok J; Pilch J; Laskawiec J; Panz B; Sliwa W
Patol Pol; 1987; 38(3-4):316-9. PubMed ID: 3328147
[No Abstract] [Full Text] [Related]
12. Auxiliary apparatus for rotatory metal-coating of specimens for electron microscopy.
PokornĂ˝ V
Folia Morphol (Praha); 1976; 24(1):14-7. PubMed ID: 780241
[No Abstract] [Full Text] [Related]
13. A technique for preparing human dermal and scar specimens for scanning electron microscopy.
Sommerlad BC; Creasey JM
J Microsc; 1975 Apr; 103(3):369-76. PubMed ID: 809589
[TBL] [Abstract][Full Text] [Related]
14. [Preparation of biological specimens for the scanning electron microscope (author's transl)].
Klein HP; Stockem W
Microsc Acta; 1976 Nov; 78(5):388-406. PubMed ID: 794634
[TBL] [Abstract][Full Text] [Related]
15. [Scanning electron microscopy studies of mammaliam sperm atozoa under various preparation conditions].
Rosenbauer KA; Schlösser HW
Verh Anat Ges; 1974; 68():855-61. PubMed ID: 4619530
[No Abstract] [Full Text] [Related]
16. A scanning electron microscopic evaluation of section and film mounting for transmisson electron microscopy.
Summers RG
Stain Technol; 1973 Nov; 48(6):337-42. PubMed ID: 4588138
[No Abstract] [Full Text] [Related]
17. Cell and organelle shrinkage during preparation for scanning electron microscopy: effects of fixation, dehydration and critical point drying.
Gusnard D; Kirschner RH
J Microsc; 1977 May; 110(1):51-7. PubMed ID: 409847
[TBL] [Abstract][Full Text] [Related]
18. A simple method of ion-etching for biological materials. An application to blood cells and spermatozoa.
Fujita T; Nagatani T; Hattori A
Arch Histol Jpn; 1974 Jan; 36(3):195-204. PubMed ID: 4598331
[No Abstract] [Full Text] [Related]
19. Observations on the fine structure of the nuclear ring of the mammalian spermatid.
Rattner JB; Olson G
J Ultrastruct Res; 1973 Jun; 43(5):438-44. PubMed ID: 4578330
[No Abstract] [Full Text] [Related]
20. Preparation of nematodes for scanning electron microscopy.
Green CD; Stone AR; Turner RH; Clark SA
J Microsc; 1975 Jan; 103(1):89-99. PubMed ID: 49435
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]