These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 4617586)

  • 1. Functional residual capacity during anaesthesia. I: Methodology.
    Hewlett AM; Hulands GH; Nunn JF; Minty KB
    Br J Anaesth; 1974 Jul; 46(7):479-85. PubMed ID: 4617586
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Functional residual capacity during anaesthesia III: Artificial ventilation.
    Hewlett AM; Hulands GH; Nunn JF; Milledge JS
    Br J Anaesth; 1974 Jul; 46(7):495-503. PubMed ID: 4617588
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Modifications of pulmonary residual volume measuring method using closed circuit helium dilution technic].
    Nigorikawa T; Muramoto N; Yoshigi H; Oishi K
    Kokyu To Junkan; 1987 Mar; 35(3):299-303. PubMed ID: 3296069
    [No Abstract]   [Full Text] [Related]  

  • 4. [A simple helium-dilution method for the determination of functional residual capacity in artificially ventilated patients (author's transl)].
    Rung I; Kämmerer H; Klaschik E
    Anaesthesist; 1980 Mar; 29(3):148-51. PubMed ID: 6769355
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Oxygen wash-in method for monitoring functional residual capacity.
    Mitchell RR; Wilson RM; Holzapfel L; Benis AM; Sierra D; Osborn JJ
    Crit Care Med; 1982 Aug; 10(8):529-33. PubMed ID: 7094601
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Functional residual capacity during anaesthesia. II. Spontaneous respiration.
    Hewlett AM; Hulands GH; Nunn JF; Heath JR
    Br J Anaesth; 1974 Jul; 46(7):486-94. PubMed ID: 4617587
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method.
    Ibañez J; Raurich JM; Moris SG
    Intensive Care Med; 1983; 9(2):91-3. PubMed ID: 6343447
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Arterial oxygenation during artificial ventilation. The effect of airway closure and of its prevention by positive end-expiratory pressure.
    McCarthy GS; Hedenstierna G
    Acta Anaesthesiol Scand; 1978; 22(6):563-9. PubMed ID: 364915
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of an acoustic helium analyzer and microprocessor for rapid measurement of absolute lung volume during mechanical ventilation.
    Gillespie DJ
    Crit Care Med; 1985 Feb; 13(2):118-21. PubMed ID: 3967501
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Normal values of functional residual capacity (author's transl)].
    Pasquis P
    Bull Physiopathol Respir (Nancy); 1975; 11(6):823-36. PubMed ID: 1230284
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differential pulmonary residual volume determinations with radioactive xenon.
    Serino T; MacDonnell K; Ishikawa S; Braverman L; Abreau CM; Johnston RP; Cloona E
    J Lab Clin Med; 1975 Jul; 86(1):160-3. PubMed ID: 1097548
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of functional residual capacity during mechanical ventilation by simultaneous exchange of two insoluble gases.
    Ozanne GM; Zinn SE; Fairley HB
    Anesthesiology; 1981 May; 54(5):413-7. PubMed ID: 7224211
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A modified helium dilution technique for measuring small lung gas volumes.
    Roy CH; Barnes RJ; Heath MF; Sensky PL
    J Dev Physiol; 1992 Feb; 17(2):87-92. PubMed ID: 1500637
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of functional residual capacity of the lung by partial CO2 rebreathing method during acute lung injury in animals.
    Brewer LM; Haryadi DG; Orr JA
    Respir Care; 2007 Nov; 52(11):1480-9. PubMed ID: 17971251
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of lung volume by multiple indicator dilution. Differences in apparent volumes of distribution of oxygen, nitrogen and argon.
    Black AM; Hahn CE; Maynard P; Scott IL
    Br J Anaesth; 1984 Mar; 56(3):289-98. PubMed ID: 6422970
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Symptomatic value of the difference between the functional plethysmographic residual capacity and the residual capacity measured by the dilution method, in obstructive diseases of the small airways].
    Vezzoli F; Marazzini L; Longhini E
    Bronches; 1975; 25(1):19-25. PubMed ID: 1227713
    [No Abstract]   [Full Text] [Related]  

  • 17. A simplified method to determine functional residual capacity during mechanical ventilation.
    Heldt GP; Peters RM
    Chest; 1978 Nov; 74(5):492-6. PubMed ID: 738086
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of functional residual capacity by sulfur hexafluoride in small-volume lungs during spontaneous breathing and mechanical ventilation.
    Schulze A; Schaller P; Töpfer A; Kirpalani H
    Pediatr Res; 1994 Apr; 35(4 Pt 1):494-9. PubMed ID: 8047388
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The accuracy of the oxygen washout technique for functional residual capacity assessment during spontaneous breathing.
    Heinze H; Schaaf B; Grefer J; Klotz K; Eichler W
    Anesth Analg; 2007 Mar; 104(3):598-604. PubMed ID: 17312216
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated sulfur hexafluoride washout functional residual capacity measurement system for any mode of mechanical ventilation as well as spontaneous respiration.
    East TD; Wortelboer PJ; van Ark E; Bloem FH; Peng L; Pace NL; Crapo RO; Drews D; Clemmer TP
    Crit Care Med; 1990 Jan; 18(1):84-91. PubMed ID: 2293972
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.