21. Rapid determination of theophylline in human plasma by high-pressure liquid chromatography. Weddle OH; Mason WD J Pharm Sci; 1976 Jun; 65(6):865-8. PubMed ID: 932972 [TBL] [Abstract][Full Text] [Related]
22. A rapid micromethod for measuring theophylline in serum by reverse-phase high-performance liquid chromatography. Soldin SJ; Hill JG Clin Biochem; 1977 Apr; 10(2):74-7. PubMed ID: 862179 [TBL] [Abstract][Full Text] [Related]
23. Assay of theophylline: comparison of EMIT on the ABA-100 to HPLC, GLC and UV procedures, with detailed evaluation of interferences. Weidner N; McDonald JM; Tieber VL; Smith CH; Kessler G; Ladenson JH; Dietzler DN Clin Chim Acta; 1979 Sep; 97(1):9-17. PubMed ID: 387295 [TBL] [Abstract][Full Text] [Related]
24. Liquid-chromatographic analysis for serum theophylline in less than 70 seconds. Kabra PM; Marton LJ Clin Chem; 1982 Apr; 28(4 Pt 1):687-9. PubMed ID: 6804117 [TBL] [Abstract][Full Text] [Related]
25. Theophylline estimation-a comparative evaluation of a gas chromatographic method and a high-performance liquid chromatographic method. Naish PJ; Chambers RE; Cooke M Ann Clin Biochem; 1979 Sep; 16(5):254-8. PubMed ID: 517984 [TBL] [Abstract][Full Text] [Related]
26. A rapid and specific high-performance liquid chromatographic assay for theophylline in biological fluids. Blanchard J; Harvey S; Morgan WJ J Chromatogr Sci; 1990 Jun; 28(6):303-6. PubMed ID: 2246353 [TBL] [Abstract][Full Text] [Related]
27. Automated determination of drugs in serum by column-switching high-performance liquid chromatography. II. Separation of theophylline and its metabolites. Matsumoto K; Kikuchi H; Iri H; Takahasi H; Umino M J Chromatogr; 1988 Mar; 425(2):323-30. PubMed ID: 3372646 [TBL] [Abstract][Full Text] [Related]
28. High-performance liquid chromatographic analysis of theophylline in serum and its use in therapeutic drug monitoring. el-Sayed YM; Islam SI J Clin Pharm Ther; 1989 Feb; 14(1):35-43. PubMed ID: 2921301 [TBL] [Abstract][Full Text] [Related]
30. Direct determination of theophylline in human serum by high-performance liquid chromatography using zwitterionic micellar mobile phase. Comparison with an enzyme multiplied immunoassay technique. Habel D; Guermouche S; Guermouche MH Analyst; 1993 Dec; 118(12):1511-3. PubMed ID: 8109754 [TBL] [Abstract][Full Text] [Related]
31. Comparison of a high performance liquid chromatographic and an enzyme immunoassay technique for quantitation of theophylline in serum. Boeckx RL; Frith EM; Simons FE Ther Drug Monit; 1979; 1(1):65-73. PubMed ID: 399811 [TBL] [Abstract][Full Text] [Related]
32. Micro-scale method for theophylline in body fluids by reversed-phase, high-pressure liquid chromatography. Orcutt JJ; Kozak PP; Gillman SA; Cummins LH Clin Chem; 1977 Mar; 23(3):599-601. PubMed ID: 837550 [TBL] [Abstract][Full Text] [Related]
33. A rapid and precise method for determining theophylline in serum. Frings CS; Keefer RC; Saloom JM Clin Toxicol; 1975; 8(5):553-61. PubMed ID: 1222528 [TBL] [Abstract][Full Text] [Related]
34. New simplified microassay for the quantitation of theophylline and its major metabolites in serum by high-performance liquid chromatography. Kester MB; Saccar CL; Rocci ML; Mansmann HC J Chromatogr; 1986 Jul; 380(1):99-108. PubMed ID: 3745398 [TBL] [Abstract][Full Text] [Related]
35. Simultaneous determination of diprophylline, proxyphylline and theophylline in serum by reversed-phase high-performance liquid chromatography. Wenk M; Eggs B; Follath F J Chromatogr; 1983 Sep; 276(2):341-8. PubMed ID: 6630383 [TBL] [Abstract][Full Text] [Related]
36. A liquid chromatographic method for determination of theophylline in serum and capillary blood--a comparison. Gartzke J; Jäger H; Vins I J Pharm Biomed Anal; 1991; 9(10-12):981-4. PubMed ID: 1822223 [TBL] [Abstract][Full Text] [Related]
37. Accurate measurements of peak variances: importance of this accuracy in the determination of the true corrected plate heights of chromatographic columns. Gritti F; Guiochon G J Chromatogr A; 2011 Jul; 1218(28):4452-61. PubMed ID: 21621787 [TBL] [Abstract][Full Text] [Related]
38. Accuracy and precision of gas-liquid chromatographic, high-pressure liquid chromatographic, and enzyme immunoassay techniques for the measurement of theophylline concentrations in serum: a comparison based on external quality assurance measurements. Wilson JF; Marshall RW; Williams J; Richens A Ther Drug Monit; 1984; 6(2):243-50. PubMed ID: 6377601 [TBL] [Abstract][Full Text] [Related]
39. Rapid assay for theophylline in clinical samples by reversed-phase high-performance liquid chromatography. Naish PJ; Cooke M; Chambers RE J Chromatogr; 1979 Aug; 163(4):363-72. PubMed ID: 544602 [TBL] [Abstract][Full Text] [Related]
40. Evaluation of chromatographic and kit immunoassay techniques for the measurement of theophylline in serum: a study based on external quality assurance measurements. Wilson JF; Williams J; Tsanaclis LM; Tedstone JE; Richens A Ther Drug Monit; 1988; 10(4):438-45. PubMed ID: 3201529 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]