These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 4654700)

  • 21. Methods for measurement of the cerebral blood flow.
    Olesen J
    Acta Neurol Scand Suppl; 1974; 57():1-134. PubMed ID: 4218434
    [No Abstract]   [Full Text] [Related]  

  • 22. Regional cerebral blood flow, intracranial pressure, and brain metabolism in comatose patients.
    Bruce DA; Langfitt TW; Miller JD; Schutz H; Vapalahti MP; Stanek A; Goldberg HI
    J Neurosurg; 1973 Feb; 38(2):131-44. PubMed ID: 4694215
    [No Abstract]   [Full Text] [Related]  

  • 23. On line in vivo measurement of tissue and blood gases in patients with severe trauma.
    Rosenbaum R; Hyes MF; Wolferth CC; Frajola R; Jones N; Matsumoto T
    Surg Gynecol Obstet; 1972 Oct; 135(4):605-7. PubMed ID: 5077729
    [No Abstract]   [Full Text] [Related]  

  • 24. Changes in intracranial pressure and other variables during the induction of general anaesthesia.
    Hulme A; Cooper R
    Proc R Soc Med; 1972 Oct; 65(10):883-4. PubMed ID: 5085085
    [No Abstract]   [Full Text] [Related]  

  • 25. Flight research program. V. Mass spectrometer in medical monitoring.
    Roman J; Brigden WH
    Aerosp Med; 1966 Dec; 37(12):1213-7. PubMed ID: 5972718
    [No Abstract]   [Full Text] [Related]  

  • 26. On-line O2 and CO2 analysis in vivo.
    Kleiman BS; Brantigan O; Zapata A
    J Assoc Adv Med Instrum; 1971; 5(4):224-6. PubMed ID: 5118804
    [No Abstract]   [Full Text] [Related]  

  • 27. Quantitative continuous measurement of blood gas tensions by mass spectrometry.
    Seylaz J; Pinard E; Correze JL; Aubineau PF; Mamo H
    J Appl Physiol; 1974 Dec; 37(6):937-41. PubMed ID: 4436229
    [No Abstract]   [Full Text] [Related]  

  • 28. Physiological effects of increased tissue pressure.
    Matsen FA; King RV; Krugmire RB; Mowery CA; Roche T
    Int Orthop; 1979; 3(3):237-44. PubMed ID: 528092
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Measurement of lung volume by multiple indicator dilution. Differences in apparent volumes of distribution of oxygen, nitrogen and argon.
    Black AM; Hahn CE; Maynard P; Scott IL
    Br J Anaesth; 1984 Mar; 56(3):289-98. PubMed ID: 6422970
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Monitoring intracranial and arterial pressure and the carbon dioxide expired fraction with tendency curves].
    Boulard G; Voinot JP; Sabathie M; Leman P
    Agressologie; 1984 May; 25(6):719-21. PubMed ID: 6435465
    [No Abstract]   [Full Text] [Related]  

  • 31. Middle ear gas composition and middle ear aeration.
    Sadé J; Luntz M; Levy D
    Ann Otol Rhinol Laryngol; 1995 May; 104(5):369-73. PubMed ID: 7747907
    [TBL] [Abstract][Full Text] [Related]  

  • 32. On-line respiratory gas monitoring.
    Blumenfeld W; Wolf S; McCluggage C; Denman R; Turney S
    Comput Biomed Res; 1973 Apr; 6(2):139-49. PubMed ID: 4512789
    [No Abstract]   [Full Text] [Related]  

  • 33. The continuous measurement of pulmonary gas exchange and mechanics.
    Turney SZ; McAslan TC; Cowley RA
    Ann Thorac Surg; 1972 Mar; 13(3):229-42. PubMed ID: 4553410
    [No Abstract]   [Full Text] [Related]  

  • 34. Evaluation of rebreathing in patients undergoing cataract surgery.
    Sabo B; Smith RB; Gilbert TJ
    Ophthalmic Surg; 1988 Apr; 19(4):249-51. PubMed ID: 3129684
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Middle ear gas composition in pathologic conditions: mass spectrometry in otitis media with effusion and atelectasis.
    Hergils L; Magnuson B
    Ann Otol Rhinol Laryngol; 1997 Sep; 106(9):743-5. PubMed ID: 9302904
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Continuous measurement of expiratory O2 and CO2 and its application. Determination of CO2 partial pressure in the mixed venous blood and pulmonary blood volume].
    Nakabayashi T
    Nihon Rinsho; 1969 Dec; 27(12):2883-91. PubMed ID: 5391806
    [No Abstract]   [Full Text] [Related]  

  • 37. Sampling of the mean alveolar gas of a respiratory cycle.
    Bargeton D; Florentin E; Menier R
    Bull Physiopathol Respir (Nancy); 1972; 8(1):142-4. PubMed ID: 5052500
    [No Abstract]   [Full Text] [Related]  

  • 38. Evaluation of a bedside monitor of regional CBF as a measure of CO2 reactivity in neurosurgical intensive care patients.
    Soukup J; Bramsiepe I; Brucke M; Sanchin L; Menzel M
    J Neurosurg Anesthesiol; 2008 Oct; 20(4):249-55. PubMed ID: 18812888
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Automatic respiratory gas monitoring.
    Turney SZ; McCluggage C; Blumenfeld W; McAslan TC; Cowley RA
    Ann Thorac Surg; 1972 Aug; 14(2):159-72. PubMed ID: 4505730
    [No Abstract]   [Full Text] [Related]  

  • 40. Argon concentration time-series as a tool to study gas dynamics in the hyporheic zone.
    Mächler L; Brennwald MS; Kipfer R
    Environ Sci Technol; 2013 Jul; 47(13):7060-6. PubMed ID: 23611693
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.