These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 466770)

  • 1. Improved automated kinetic determination of uric acid in serum by use of uricase/catalase/aldehyde dehydrogenase.
    Bartl K; Brandhuber M; Ziegenhorn J
    Clin Chem; 1979 Apr; 25(4):619-21. PubMed ID: 466770
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Enzyme-coupled measurement of uric acid in serum with a centrifugal analyzer.
    White RM; Cross RE; Savory J
    Clin Chem; 1977 Sep; 23(9):1538-40. PubMed ID: 890896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The reliability of a mechanized procedure (Perkin-Elmer C4) for the Enzymatic determination of uric acid according to Kageyama.
    Haeckel R
    J Clin Chem Clin Biochem; 1976 Apr; 14(4):165-71. PubMed ID: 1271017
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The use of aldehyde dehydrogenase to determine H2O2 -producing reactions. I. The determination of the uric acid concentration.
    Haeckel R
    J Clin Chem Clin Biochem; 1976 Mar; 14(3):101-7. PubMed ID: 932643
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A sensitive determination of uric acid in serum using uricase/catalase/formaldehyde dehydrogenase coupled with formate dehydrogenase.
    Kayamori Y; Katayama Y
    Clin Biochem; 1994 Apr; 27(2):93-7. PubMed ID: 8070073
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of uric acid in serum: comparison of a standard enzymatic method and isotachophoresis.
    Oerlemans F; Verheggen T; Mikkers F; Everaerts F; de Bruyn C
    Adv Exp Med Biol; 1979; 122B():435-40. PubMed ID: 546158
    [No Abstract]   [Full Text] [Related]  

  • 7. Evaluation of a kinetic uricase method for serum uric acid assay by predicting background absorbance of uricase reaction solution with an integrated method.
    Liao F; Zhao YS; Zhao LN; Tao J; Zhu XY; Liu L
    J Zhejiang Univ Sci B; 2006 Jun; 7(6):497-502. PubMed ID: 16691645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aldehyde dehydrogenase interference in the Haeckel enzymic technique for uric acid determination.
    Zoppi F; Fenili D; Marcovina S; Peracino A
    Clin Chem; 1980 Jan; 26(1):178. PubMed ID: 7356564
    [No Abstract]   [Full Text] [Related]  

  • 9. New ultraviolet (340 nm) method for assay of uric acid in serum or plasma.
    Trivedi RC; Rebar L; Desai K; Stong LJ
    Clin Chem; 1978 Apr; 24(4):562-6. PubMed ID: 639259
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of four methods for measuring uric acid: copper-chelate, phosphotungstate, manual uricase, and automated kinetic uricase.
    Lum G; Gambino SR
    Clin Chem; 1973 Oct; 19(10):1184-6. PubMed ID: 4741958
    [No Abstract]   [Full Text] [Related]  

  • 11. [Adaptation of the SMAC for the determination of uric acid with an uricase/perioxidase procedure (author's transl)].
    Scholer A; Müller E; Toth F; Vonderschmitt DJ
    J Clin Chem Clin Biochem; 1978 Apr; 16(4):255-7. PubMed ID: 641455
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development and improvement of a commercial uric acid enzymatic determination kit on a centrifugal fast analyzer.
    Zoppi F; Peracino A; Marcovina S; Fenili D
    J Clin Chem Clin Biochem; 1980 Jan; 18(1):59-65. PubMed ID: 6987330
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Uric acid estimation: a comparison of the manual uricase-UV and the phosphotungstate auto-analyzer methods.
    Itiaba K; Hsiung MW; Crawhall JC
    Clin Biochem; 1975 Oct; 8(5):316-9. PubMed ID: 1201623
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Problems associated with the measurement of uric acid using two enzyme-mediated reaction systems.
    James DR; Price CP
    Ann Clin Biochem; 1984 Sep; 21 ( Pt 5)():405-10. PubMed ID: 6508211
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Uricase immobilized onto nylon tube for use in automated analysis of serum urate.
    Salleh AB; Ledingham WM
    Anal Biochem; 1981 Sep; 116(1):40-7. PubMed ID: 7304984
    [No Abstract]   [Full Text] [Related]  

  • 16. Characterization of a uricase from Bacillus fastidious A.T.C.C. 26904 and its application to serum uric acid assay by a patented kinetic uricase method.
    Zhao Y; Zhao L; Yang G; Tao J; Bu Y; Liao F
    Biotechnol Appl Biochem; 2006 Sep; 45(Pt 2):75-80. PubMed ID: 16689679
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A precise semi-automated uricase method for determining uric acid in serum or urine.
    MacRae AR
    Clin Biochem; 1977 Feb; 10(1):29-31. PubMed ID: 837524
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calorimetric enzymic measurement of uric acid in serum.
    Rehak NN; Janes G; Young DS
    Clin Chem; 1977 Feb; 23(2 PT. 1):195-9. PubMed ID: 832382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automated enzymatic micromethod for determination of uric acid in serum and urine with a centrifugal analyzer.
    Pesce MA; Bodourian SH; Nicholson JF
    Clin Chem; 1974 Sep; 20(9):1231-3. PubMed ID: 4412135
    [No Abstract]   [Full Text] [Related]  

  • 20. [Spectrophotometric determination of uric acid in serum using a titanium (IV)-porphyrin complex].
    Matsubara C; Yokoi Y; Nakamichi N; Takamura K
    Yakugaku Zasshi; 1994 Jan; 114(1):48-53. PubMed ID: 8133459
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.