These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 466798)

  • 1. Accuracy of a fully enzymatic method for creatinine, as judged by isotope dilution-mass fragmentography.
    Björkhem I; Blomstrand R; Ohman G
    Clin Chem; 1979 Sep; 25(9):1666-7. PubMed ID: 466798
    [No Abstract]   [Full Text] [Related]  

  • 2. Enzymatic vs. Jaffé (continuous-flow) assay of creatinine in serum.
    Hearne CR; Fraser CG
    Clin Chem; 1979 Sep; 25(9):1665-6. PubMed ID: 466797
    [No Abstract]   [Full Text] [Related]  

  • 3. Kinetic approach for the enzymic determination of creatinine.
    Perakis N; Wolff CM
    Clin Chem; 1984 Nov; 30(11):1792-6. PubMed ID: 6488523
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Kinetic enzymatic determination of creatinine by a rapid semiautomated procedure.
    Bonvicini P; Ceriotti G; de 'Besi T
    J Clin Chem Clin Biochem; 1982 Apr; 20(4):185-9. PubMed ID: 7077235
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Combined enzymic-Jaffé method for determination of creatinine in serum.
    Masson P; Ohlsson P; Björkhem I
    Clin Chem; 1981 Jan; 27(1):18-21. PubMed ID: 7449105
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Candidate reference method for determining serum creatinine by isocratic HPLC: validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits.
    Thienpont LM; Van Landuyt KG; Stöckl D; De Leenheer AP
    Clin Chem; 1995 Jul; 41(7):995-1003. PubMed ID: 7600702
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a new diagnostic kit for the enzymatic determination of creatinine.
    Lanser A; Blijenberg BG; Leijnse B
    J Clin Chem Clin Biochem; 1979 Oct; 17(10):633-8. PubMed ID: 501291
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.
    Lindbäck B; Bergman A
    Clin Chem; 1989 May; 35(5):835-7. PubMed ID: 2541950
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Immobilized enzyme nylon tube reactors: creatininase and creatine kinase linked to the pyruvate kinase-lactate dehydrogenase indicator system in the detection of creatinine and creatine.
    Sundaram PV; Igloi MP
    Clin Chim Acta; 1979 Jun; 94(3):295-307. PubMed ID: 466819
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of an immobilized enzyme nylon tube reactor incorporating a four enzyme system for creatinine analysis.
    Ginman R; Colliss JS; Knox JM
    Appl Biochem Biotechnol; 1983 Jun; 8(3):213-26. PubMed ID: 6679191
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).
    Fernández-Fernández M; Rodríguez-González P; Añón Álvarez ME; Rodríguez F; Menéndez FV; García Alonso JI
    Anal Chem; 2015 Apr; 87(7):3755-63. PubMed ID: 25751287
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enzymatic analysis of acetylpolyamine.
    Tomita K; Miura T; Ota S; Nomura K
    J Pharm Biomed Anal; 1998 Dec; 18(4-5):889-92. PubMed ID: 9919993
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Results of the recalibration of creatinine measurement with the modular Beckman Coulter Jaffe creatinine method.
    Fillée C; Vranken G; Othmane M; Philippe M; Allaeys JM; Courbe A; Ruelle JL; Peeters R
    Clin Chem Lab Med; 2011 Dec; 49(12):1987-99. PubMed ID: 21801031
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Specific enzymatic spectrophotometric assay of adenosine 5'-diphosphate.
    Tornheim K; Schultz V
    Anal Biochem; 1993 Jun; 211(2):329-30. PubMed ID: 8317712
    [No Abstract]   [Full Text] [Related]  

  • 15. The use of an enzymatic kit to measure plasma creatinine in the mouse and three other species.
    Evans GO
    Comp Biochem Physiol B; 1986; 85(1):193-5. PubMed ID: 3769452
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Kinetic enzymatic method for determining serum creatinine.
    Moss GA; Bondar RJ; Buzzelli DM
    Clin Chem; 1975 Sep; 21(10):1422-6. PubMed ID: 1157307
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of some routine method used in clinical chemistry as judged by isotope dilution-mass spectrometry.
    Björkhem I; Bergman A; Falk O; Kallner A; Lantto O; Svensson L; Akerlöf E; Blomstrand R
    Clin Chem; 1981 May; 27(5):733-5. PubMed ID: 7014032
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Do enzymatic and Jaffé creatinine assays produce comparable results for pre and post dialysis specimens from patients with chronic renal failure?
    Rumbelow BD; Peake MJ; Ehrhardt V
    Clin Lab; 2000; 46(11-12):589-90. PubMed ID: 11109507
    [No Abstract]   [Full Text] [Related]  

  • 19. HPLC with enzymatic detection as a candidate reference method for serum creatinine.
    Linnet K; Bruunshuus I
    Clin Chem; 1991 Oct; 37(10 Pt 1):1669-75. PubMed ID: 1914163
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of an isotope dilution GC-MS procedure for the routine determination of creatinine in complex serum samples.
    Fernández-Fernández M; González-Antuña A; Rodríguez-González P; Añón Álvarez ME; Álvarez FV; García Alonso JI
    Clin Chim Acta; 2014 Apr; 431():96-102. PubMed ID: 24508629
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.