These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
90 related articles for article (PubMed ID: 4686283)
21. Microbiological aspects of ethylene oxide sterilization. 3. Effects of humidity and water activity on the sporicidal activity of ethylene oxide. Kereluk K; Gammon RA; Lloyd RS Appl Microbiol; 1970 Jan; 19(1):157-62. PubMed ID: 4984365 [TBL] [Abstract][Full Text] [Related]
22. [Health hazards in hospital personnel related to use of ethylene oxide in sterilization processes]. Tyras H Med Pr; 1997; 48(3):325-33. PubMed ID: 9312659 [TBL] [Abstract][Full Text] [Related]
23. [Use of ethylene oxide and handling of ethylene oxide sterilizers]. Herzog V; Jung W; Horn H Z Gesamte Hyg; 1981 Nov; 27(11):845-9. PubMed ID: 7344338 [No Abstract] [Full Text] [Related]
24. Ethylene oxide sterilization: III--Influence of carrier nature in a biological monitor performance. Pinto TJ; Saito T; Iossif M J Pharm Sci Technol; 1994; 48(3):155-8. PubMed ID: 8069517 [TBL] [Abstract][Full Text] [Related]
25. [Sterilization of dressings by ethylene oxide. I. Physisorption]. Dauvois C; Chaigneau M; Le Moan G Ann Pharm Fr; 1982 Jul; 40(2):125-32. PubMed ID: 7137808 [No Abstract] [Full Text] [Related]
26. [The suitability of bioindicators according to DIN 58948 part 4 for monitoring gas-sterilizers (author's transl)]. Adam W; Marcy G Zentralbl Bakteriol Mikrobiol Hyg B; 1980; 171(6):538-43. PubMed ID: 6258352 [TBL] [Abstract][Full Text] [Related]
28. Ethylene oxide sterilization of spores in hygroscopic environments. OPFELL JB; HOHMANN JP; LATHAM AB J Am Pharm Assoc Am Pharm Assoc; 1959 Nov; 48():7617-9. PubMed ID: 13854179 [No Abstract] [Full Text] [Related]
29. [The stability of biological indicators used for monitoring ethylene oxide gas sterilization]. Jakimiak B; Bielicka A Rocz Panstw Zakl Hig; 1994; 45(3):241-8. PubMed ID: 7777783 [TBL] [Abstract][Full Text] [Related]
30. [The influence of load size on the result of ethylene oxide gas sterilization]. Jakimiak B Rocz Panstw Zakl Hig; 1995; 46(3):299-304. PubMed ID: 8552971 [TBL] [Abstract][Full Text] [Related]
31. [Gas sterilization with ethylene oxide, with special reference to the use in the hospital field]. Buzzanca E Riv Ital Ig; 1967; 27(3):225-48. PubMed ID: 5597657 [No Abstract] [Full Text] [Related]
33. [The influence of formaldehyde, ethylene oxide, high pressure on the tension of silk sutures]. Lin YL; Cai JH Zhonghua Hu Li Za Zhi; 1997 May; 32(5):259-60. PubMed ID: 9304983 [TBL] [Abstract][Full Text] [Related]
34. [Diffusion of ethylene oxide in polymer materials intended for medical use]. Komarkova NI; Likhtman TV Med Tekh; 1983; (3):33-8. PubMed ID: 6888220 [TBL] [Abstract][Full Text] [Related]
35. Lens incorporated germicides. II. Benzalkonium chloride vs. ethylene sterilization. Mote EM; Hill RM J Am Optom Assoc; 1970 Mar; 41(3):260-2. PubMed ID: 5424653 [No Abstract] [Full Text] [Related]
36. [Possibilities of further improving biological sterilization tests]. Dobberkau HJ; Steiger E; Nagel M Z Gesamte Hyg; 1980; 26(10):717-21. PubMed ID: 6781152 [No Abstract] [Full Text] [Related]
37. [Effects of sterilization of the human dura mater by ethylene oxide]. Fortuna AB; Vieira RW; Mortali N; Terzi RG; Yamamoto M; do Amaral CM Arq Bras Cardiol; 1981 Jan; 36(1):41-4. PubMed ID: 7271517 [No Abstract] [Full Text] [Related]
38. The influence of water on the resistance of spores to inactivation by gaseous ethylene oxide. Dadd AH; Town MM; McCormick KE J Appl Bacteriol; 1985 Jun; 58(6):613-21. PubMed ID: 4030527 [TBL] [Abstract][Full Text] [Related]
39. [Microbiological evaluation of sterilization of selected pharmaceutical raw materials with ethylene oxide]. Woźniak-Parnowska W; Najer A; Sobiczewska M Acta Pol Pharm; 1980; 37(1):113-9. PubMed ID: 7395545 [No Abstract] [Full Text] [Related]