These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 4686592)

  • 1. Roentgenographic identification of Starr-Edwards prostheses.
    Bonchek LI; Dobbs JL; Matar AF; Chappel P; Starr A
    Circulation; 1973 Jan; 47(1):154-61. PubMed ID: 4686592
    [No Abstract]   [Full Text] [Related]  

  • 2. Images in clinical medicines. Starr-Edwards heart valves.
    Piazza N; Gregoire J
    N Engl J Med; 2008 May; 358(21):e24. PubMed ID: 18499563
    [No Abstract]   [Full Text] [Related]  

  • 3. A Starr-Edwards model 6120 mechanical prosthesis in the mitral valve position for 38 years.
    Peterman MA; Donsky MS; Matter GJ; Roberts WC
    Am J Cardiol; 2006 Mar; 97(5):756-8. PubMed ID: 16490451
    [No Abstract]   [Full Text] [Related]  

  • 4. Computer simulated "Virtual TAVR" to guide TAVR in the presence of a previous Starr-Edwards mitral prosthesis.
    Obaid DR; Smith D; Gilbert M; Ashraf S; Chase A
    J Cardiovasc Comput Tomogr; 2019; 13(1):38-40. PubMed ID: 30322774
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Doppler haemodynamic profiles of clinically and echocardiographically normal mitral and aortic valve prostheses.
    Nihoyannopoulos P; Kambouroglou D; Athanassopoulos G; Nadazdin A; Smith P; Oakley CM
    Eur Heart J; 1992 Mar; 13(3):348-55. PubMed ID: 1597221
    [TBL] [Abstract][Full Text] [Related]  

  • 6. REPLACEMENT OF THE AORTIC AND MITRAL VALVES USING THE STARR-EDWARDS BALL-VALVE PROSTHESIS: A REPORT OF 50 CASES.
    CALLAGHAN JC
    Can Med Assoc J; 1964 Aug; 91(9):411-21. PubMed ID: 14179062
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Value of a cinefluoroscopic assessment of the Lillehei-Kaster prosthetic heart valves.
    Paquet E; Blanchette J; Desaulniers D; Després JP; Lemieux M
    Cardiovasc Radiol; 1978 Oct; 1(4):229-32. PubMed ID: 743717
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcatheter aortic valve implantation in a patient with previous Starr-Edwards mitral valve prosthesis.
    Rahman MS; Roy D; Brecker SJ
    Heart; 2013 Feb; 99(3):217-8. PubMed ID: 23038790
    [No Abstract]   [Full Text] [Related]  

  • 9. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves.
    Williams GA; Labovitz AJ
    Am J Cardiol; 1985 Aug; 56(4):325-32. PubMed ID: 4025173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Current status of the Beall, Bjork-Shiley, Braunwald-Cutter, Lillehei-Kaster and Smeloff-Cutter cardiac valve prostheses.
    Brawley RK; Donahoo JS; Gott VL
    Am J Cardiol; 1975 Jun; 35(6):855-65. PubMed ID: 124127
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
    Falk RH; Mackinnon J; Wainscoat J; Melikian V; Bignell AH
    Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Macroscopic aspects of cloth-covered Starr-Edwards prostheses at reoperation: what the precursory valve teaches us.
    Tsukamoto S; Shiono M; Orime Y; Hata H; Yagi S; Okumura H; Inoue T; Kimura S; Sezai A; Sezai Y
    J Heart Valve Dis; 1998 Sep; 7(5):556-60. PubMed ID: 9793856
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Excellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case.
    Tochii M; Takagi Y; Kaneko K; Ishida M; Akita K; Higuchi Y; Ando M
    Ann Thorac Cardiovasc Surg; 2013; 19(1):76-8. PubMed ID: 22785448
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Forty-year survival with Smeloff-Cutter and Starr-Edwards prostheses.
    Suezawa T; Morimoto T; Jinno T; Tago M
    Ann Thorac Surg; 2008 Mar; 85(3):e14-6. PubMed ID: 18291143
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical valves: a comparative analysis of the Starr-Edwards and Björk-Shiley prostheses.
    Murphy DA; Levine FH; Buckley MJ; Swinski L; Daggett WM; Akins CW; Austen WG
    J Thorac Cardiovasc Surg; 1983 Nov; 86(5):746-52. PubMed ID: 6632948
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Forty-year survival with the Starr-Edwards heart valve prosthesis.
    Gao G; Wu Y; Grunkemeier GL; Furnary AP; Starr A
    J Heart Valve Dis; 2004 Jan; 13(1):91-6; discussion 96. PubMed ID: 14765846
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Echo-Doppler evaluation of normal Starr-Edwards prostheses in mitral and aortic position].
    Lefebvre E; Isorni C; Rey JL; Lesbre JP
    Arch Mal Coeur Vaiss; 1987 Jun; 80(7):1105-14. PubMed ID: 3118834
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transapical valve-in-valve TAVI in a patient with two failing surgical bioprostheses with Edwards SAPIEN 3 valves using a cerebral protection system.
    Wolf A; Schmitz T; Bigdeli H; Naber CK
    EuroIntervention; 2016 Mar; 11(12):1432. PubMed ID: 26999683
    [No Abstract]   [Full Text] [Related]  

  • 19. Patient with a Starr-Edwards prosthesis in the aortic position for 40 years.
    Miranda M; do Nascimento L; Haddad MR; Haddad WT; Haddad WT; Buffolo E
    J Heart Valve Dis; 2013 Sep; 22(5):648-50. PubMed ID: 24383375
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transapical transcatheter aortic valve implantation in the presence of a mitral prosthesis.
    Soon JL; Ye J; Lichtenstein SV; Wood D; Webb JG; Cheung A
    J Am Coll Cardiol; 2011 Aug; 58(7):715-21. PubMed ID: 21816307
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.