These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 4691291)

  • 1. To the editor: limitations of 133 Xe washout technique in estimation of renal blood flow.
    Gutman RA
    Am J Physiol; 1973 Mar; 224(3):723. PubMed ID: 4691291
    [No Abstract]   [Full Text] [Related]  

  • 2. Limitations of 133 Xe washout technique in estimation of renal blood flow.
    Mowat P; Lupu AN; Maxwell MH
    Am J Physiol; 1972 Sep; 223(3):682-8. PubMed ID: 5055326
    [No Abstract]   [Full Text] [Related]  

  • 3. Evaluation of the measurement of the renal blood flow by the 133 Xe washout technique in dogs.
    Kahn RJ; Gottignies P; Vanherweghem JL; Lambert PP
    Rev Eur Etud Clin Biol; 1972 Apr; 17(4):389-94. PubMed ID: 4562452
    [No Abstract]   [Full Text] [Related]  

  • 4. Comparison of xenon-133 washout and renal venous flow in the isolated perfused canine kidney.
    Bovee KC; Berkowitz HD; Miller LD
    Am J Vet Res; 1972 Mar; 33(3):511-7. PubMed ID: 5014459
    [No Abstract]   [Full Text] [Related]  

  • 5. Comparison of xenon-133 washout curves from the kidney with direct measurement of renal venous outflow.
    Lewis DH; Fritjofsson A
    Scand J Urol Nephrol; 1968; 2(1):62-3. PubMed ID: 4893377
    [No Abstract]   [Full Text] [Related]  

  • 6. A weighted least-squares technique for the analysis of kinetic data and its application to the study of renal xenon washout in dogs and man.
    Dell RB; Sciacca R; Lieberman K; Case DB; Cannon PJ
    Circ Res; 1973 Jan; 32(1):71-84. PubMed ID: 4684130
    [No Abstract]   [Full Text] [Related]  

  • 7. Intrarenal hemodynamics of the rat kidney determined by the xenon washout technique.
    Grandchamp A; Ayer G; Scherrer JR; Truniger B
    Nephron; 1971; 8(1):33-45. PubMed ID: 5155598
    [No Abstract]   [Full Text] [Related]  

  • 8. Comparative measurement of renal blood flow by xenon-133 clearance and electromagnetic flowmeter methods.
    Newman MH; Skinner DB
    Am Surg; 1969 Dec; 35(12):879-85. PubMed ID: 5355249
    [No Abstract]   [Full Text] [Related]  

  • 9. [Measurement of global renal blood flow after the analysis of the Xe 133 elution curve].
    Kahn RJ; Gottignies P; Vanherweghem JL; Lambert PP
    J Urol Nephrol (Paris); 1971; 77(4):364-7. PubMed ID: 4933964
    [No Abstract]   [Full Text] [Related]  

  • 10. [Study of renal cortical and medullary flow. Experimental studies with Xe-133 in basal conditions and during hypotension induced with "Arfonad"].
    Sampietro G; Sarti G; Citone G; Pagni I; Carotenuto F
    Nunt Radiol; 1968 Nov; 34(11):1281-5. PubMed ID: 5744771
    [No Abstract]   [Full Text] [Related]  

  • 11. Xenon-133 washout for measuring intrarenal blood flow in the micropuncture rat.
    Kinney MJ; Quinones J; Rudich S; DiScala V
    Am J Physiol; 1974 Sep; 227(3):657-64. PubMed ID: 4416918
    [No Abstract]   [Full Text] [Related]  

  • 12. Intrarenal blood flow in dogs with constriction of the inferior thoracic vena cava.
    Newsome HH; Kafka MS; Bartter FC
    Am J Physiol; 1971 Jul; 221(1):48-52. PubMed ID: 5555813
    [No Abstract]   [Full Text] [Related]  

  • 13. Values for intrarenal distribution of blood flow using xenon-133 in the anesthetized dog.
    Bovee KC; Webster GD
    Am J Vet Res; 1972 Mar; 33(3):501-9. PubMed ID: 5014458
    [No Abstract]   [Full Text] [Related]  

  • 14. [Renal blood flow in hepatic cirrhosis determined by the Xe 133 washout method].
    Zuin R; Gatta A; Prandoni P; Finocchio GF; Merkel C; Ruol A
    Minerva Nefrol; 1976; 23(2):109-15. PubMed ID: 794762
    [No Abstract]   [Full Text] [Related]  

  • 15. Renal blood flow measured by radioxenon 133: evaluation of a technique in dogs.
    Goluboff B; Bogash M; Cope C; Wolgin W; Isard HJ
    J Appl Physiol; 1969 Feb; 26(2):208-14. PubMed ID: 5765212
    [No Abstract]   [Full Text] [Related]  

  • 16. Renal blood flow measured with Xenon-133 wash-out technique and with an electromagnetic flowmeter.
    Ladefoged J; Pedersen F; Doutheil U; Deetjen P; Selkurt EE
    Pflugers Arch Gesamte Physiol Menschen Tiere; 1965 Jun; 284(3):195-200. PubMed ID: 5218648
    [No Abstract]   [Full Text] [Related]  

  • 17. Regional cerebral flow in man measured externally following intra-arterial administration of 85-Kr or 133-Xe dissolved in saline.
    Hoedt-Rasmussen K
    Acta Neurol Scand Suppl; 1965; 14():65-8. PubMed ID: 5214105
    [No Abstract]   [Full Text] [Related]  

  • 18. Renal blood flow measurement with xenon-133 at the time of operation for renal artery stenosis.
    Lewis DH; Bergentz SE
    Surgery; 1966 Jun; 59(6):1043-9. PubMed ID: 5937950
    [No Abstract]   [Full Text] [Related]  

  • 19. Renal blood flow in isolated kidneys measured with an electromagnetic flowmeter and by xenom-133 and krypton-85 wash-out techniques.
    Ladefoged J; Pedersen F
    Pflugers Arch Gesamte Physiol Menschen Tiere; 1968; 299(1):30-7. PubMed ID: 5243671
    [No Abstract]   [Full Text] [Related]  

  • 20. Microkymography of the renal papilla in rats.
    Böttcher W; Steinhausen M
    Bibl Anat; 1977; (16 Pt 2):131-4. PubMed ID: 603497
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.