BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 4694112)

  • 21. Ankle systolic pressure in lower limb arteriosclerosis measured by the use of an ultrasound flow detector.
    Myhre HO
    J Oslo City Hosp; 1971; 21(11):183-90. PubMed ID: 5157590
    [No Abstract]   [Full Text] [Related]  

  • 22. Hydrostatic systolic toe pressure for diagnosis of peripheral ischaemic vessel disease in diabetes mellitus.
    Chantelau E; Sambraus HW
    Eur J Vasc Endovasc Surg; 1996 Jul; 12(1):125-6. PubMed ID: 8696888
    [No Abstract]   [Full Text] [Related]  

  • 23. Measurements of systolic pressure in the limbs of patients with arterial occlusive disease.
    Bell G; Nielsen PE; Wolfson B; Ulrich J; Engell HC; Lassen NA
    Surg Gynecol Obstet; 1973 Feb; 136(2):177-81. PubMed ID: 4686761
    [No Abstract]   [Full Text] [Related]  

  • 24. Hydrostatic toe-pressure measurement for assessment of limb ischaemia.
    Chantelau E; Sambraus HW
    Lancet; 1995 Sep; 346(8978):854. PubMed ID: 7674791
    [No Abstract]   [Full Text] [Related]  

  • 25. A comparison between the ankle systolic pressure and mercury strain gauge plethysmography in the assessment of patients with arterial disease of the lower limbs.
    Steer HW; Fletcher EW; Morris PJ
    Surgery; 1980 Nov; 88(5):636-41. PubMed ID: 7434203
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Measuring systolic ankle and toe pressure using the strain gauge technique--a comparison study between mercury and indium-gallium strain gauges.
    Broholm R; Wiinberg N; Simonsen L
    Scand J Clin Lab Invest; 2014 Sep; 74(6):555-9. PubMed ID: 24724580
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Lower limb systolic pressure measurements: technique and clinical applications.
    Yao JS; Peterson LK; Payne K
    Int Angiol; 1985; 4(1):31-9. PubMed ID: 3912445
    [No Abstract]   [Full Text] [Related]  

  • 28. Comparison of lower limb arterial assessments using color-duplex ultrasound and ankle/brachial pressure index measurements.
    Allen J; Oates CP; Henderson J; Jago J; Whittingham TA; Chamberlain J; Jones NA; Murray A
    Angiology; 1996 Mar; 47(3):225-32. PubMed ID: 8638864
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [The correlation between toe- and ankle pressure, clinical symptoms and angiography in patients with leg ischemia].
    Friethriksson JO; Guethmundsson J; Logason K
    Laeknabladid; 2005 Oct; 91(10):749-53. PubMed ID: 16219974
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Strain-gauge measurement of the distal systolic blood pressure in occlusive arterial conditions].
    Lassen NA
    Ugeskr Laeger; 1975 Feb; 137(7):365-9. PubMed ID: 1118929
    [No Abstract]   [Full Text] [Related]  

  • 31. [Doppler sonography diagnosis of restenosis after percutaneous transluminal angioplasty: sensitivity and specificity of the pedal-brachial index in relation to changes in absolute arterial blood pressure].
    Radak Dj; Laps KH; Jeger KA; Ilijevski N; Vojić M
    Srp Arh Celok Lek; 1998; 126(3-4):83-91. PubMed ID: 9863361
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Specificity and normality of peripheral systolic pressure measurement by the ultrasound Doppler technic in healthy angiography-imaged extremities].
    Köhler M; Krüpe M
    Z Kardiol; 1985 Jan; 74(1):39-45. PubMed ID: 3883663
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Doppler techniques for lower extremity arterial diagnosis.
    Zierler RE
    Herz; 1989 Apr; 14(2):126-33. PubMed ID: 2656456
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Revitalizing the ischemic limb.
    Baker WH; Barnes RW
    Geriatrics; 1973 Dec; 28(12):56-60. PubMed ID: 4758651
    [No Abstract]   [Full Text] [Related]  

  • 35. Age-related attenuation of conduit artery blood flow response to passive heating differs between the arm and leg.
    Oue A; Asashima C; Oizumi R; Ichinose-Kuwahara T; Kondo N; Inoue Y
    Eur J Appl Physiol; 2018 Nov; 118(11):2307-2318. PubMed ID: 30083884
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Ankle blood pressures in vascular insufficiency involving the legs.
    Lennihan R; Mackereth M
    J Clin Ultrasound; 1973 Jun; 1(2):120-4. PubMed ID: 4203968
    [No Abstract]   [Full Text] [Related]  

  • 37. Bioelectrical impedance sphygmography for hydrostatic toe pressure measurement: a new non-invasive method to assess limb ischaemia.
    Beyenal-Ogmen B
    Vasa; 1999 Feb; 28(1):15-8. PubMed ID: 10191701
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The validity and reliability of automated and manually measured toe blood pressure in ischemic legs of diabetic patients.
    Påhlsson HI; Lund K; Jörneskog G; Gush R; Wahlberg E
    Eur J Vasc Endovasc Surg; 2008 Nov; 36(5):576-81. PubMed ID: 18801666
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Validation of a method for determination of the ankle-brachial index in the seated position.
    Gornik HL; Garcia B; Wolski K; Jones DC; Macdonald KA; Fronek A
    J Vasc Surg; 2008 Nov; 48(5):1204-10. PubMed ID: 18829231
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral arterial disease.
    Allen J; Overbeck K; Nath AF; Murray A; Stansby G
    J Vasc Surg; 2008 Apr; 47(4):794-802. PubMed ID: 18381141
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]