These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 4729164)

  • 1. A signal generator providing independent control of trapezoidal waveform parameters.
    Bartlett JR
    Physiol Behav; 1973 Aug; 11(2):255-7. PubMed ID: 4729164
    [No Abstract]   [Full Text] [Related]  

  • 2. A differential microvolt test signal adjustable to given laboratory requirements.
    Sheatz GC
    Psychophysiology; 1972 Nov; 9(6):658-9. PubMed ID: 5076040
    [No Abstract]   [Full Text] [Related]  

  • 3. Cardiovascular response measures with simple integrated circuit amplifiers.
    Jernstedt GC; White WF
    Psychophysiology; 1974 Mar; 11(2):211-5. PubMed ID: 4821621
    [No Abstract]   [Full Text] [Related]  

  • 4. A simple method for recording activity patterns of small animals.
    Thiel V; Barnes DS; Mrosovsky N
    Physiol Behav; 1972 Mar; 8(3):549-51. PubMed ID: 5037553
    [No Abstract]   [Full Text] [Related]  

  • 5. Apparatus note: a system for detecting and recording movements of the head.
    Beschle RG; Cirillo L; Wapner S
    Percept Mot Skills; 1972 Dec; 35(3):725-6. PubMed ID: 4643961
    [No Abstract]   [Full Text] [Related]  

  • 6. A compact infrasound and pressure waveform generator for use with small cavities.
    Stagg J
    J Med Eng Technol; 1980 Jul; 4(4):186-9. PubMed ID: 7411583
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [A differential amplifier of biopotenials on semiconductor apparatuses].
    TIMOFEEVA TE
    Nov Med Tekh (1959); 1962; 2():78-82. PubMed ID: 13985089
    [No Abstract]   [Full Text] [Related]  

  • 8. Interference suppression in differential transistor amplifiers having unbalances.
    Il'inskii GV
    Biomed Eng (NY); 1968; 2(5):256-8. PubMed ID: 5760712
    [No Abstract]   [Full Text] [Related]  

  • 9. [Pre-amplifier with transistors for medico-biological research].
    Il'inskiÄ­ GV
    Fiziol Zh SSSR Im I M Sechenova; 1968 Nov; 54(11):1378-80. PubMed ID: 5738722
    [No Abstract]   [Full Text] [Related]  

  • 10. A torque device for studies of primate limb movements.
    Atkin A; Brooks VB; Pischinger S
    Physiol Behav; 1974 Jan; 12(1):127-9. PubMed ID: 4203992
    [No Abstract]   [Full Text] [Related]  

  • 11. A system for accurate on-line calibration of multiple unit potential recording.
    Irwin DA; Criswell HE
    Physiol Behav; 1974 Apr; 12(4):703-5. PubMed ID: 4824394
    [No Abstract]   [Full Text] [Related]  

  • 12. [Semiconductor preamplifier for microelectrode work].
    Shliafer TP
    Fiziol Zh SSSR Im I M Sechenova; 1967 May; 53(5):596-8. PubMed ID: 5609958
    [No Abstract]   [Full Text] [Related]  

  • 13. [Method of construction of input cascade of the amplifier for the field transistors].
    Agizim GM
    Nov Med Tekh; 1975; (4):63-6. PubMed ID: 1235573
    [No Abstract]   [Full Text] [Related]  

  • 14. A solid-state ultrasonic activity-recording unit.
    McClure G; Forgays DG; Whitmore DG
    Am J Psychol; 1973 Sep; 86(3):647-50. PubMed ID: 4780128
    [No Abstract]   [Full Text] [Related]  

  • 15. [Transistorized amplifier of microelectrode leads with expanded possibilities for application].
    Dan'ko SG; KurchavyÄ­ GG
    Fiziol Zh SSSR Im I M Sechenova; 1973 Aug; 59(8):1293-5. PubMed ID: 4790413
    [No Abstract]   [Full Text] [Related]  

  • 16. A time-locked photon isolated calibrator.
    Scobey RP
    Electroencephalogr Clin Neurophysiol; 1972 May; 32(5):568-70. PubMed ID: 4112309
    [No Abstract]   [Full Text] [Related]  

  • 17. An inexpensive, high-performance microelectrode preamplifier system.
    Schade CP
    IEEE Trans Biomed Eng; 1969 Jul; 16(3):222-3. PubMed ID: 5806959
    [No Abstract]   [Full Text] [Related]  

  • 18. A combined oscillator-detector circuit for programmed laboratory sequencers.
    Lipton VP; Lipton A
    J Sci Instrum; 1969 Feb; 2(2):219-20. PubMed ID: 5798664
    [No Abstract]   [Full Text] [Related]  

  • 19. The measurement of oxygen microcathode currents by means of a field-effect transistor operational amplifier system with digital display.
    Hahn CE
    J Sci Instrum; 1969 Jan; 2(1):48-50. PubMed ID: 5798203
    [No Abstract]   [Full Text] [Related]  

  • 20. [Appliance for programmed muscle stretching and record of the response with a semiconductor tensometer amplifier].
    Gnit'ko RV; Izakov VIa; Markhasin VS; Orlov RS
    Fiziol Zh SSSR Im I M Sechenova; 1967 May; 53(5):598-600. PubMed ID: 5609959
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.