These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 473422)

  • 1. Ultrasonic pulsed Doppler transoesophageal measurement of aortic haemodynamics in humans.
    Histand MB; Wells MK; Reeves JT; Sodal IE; Adamson HP; Willson JT
    Ultrasonics; 1979 Sep; 17(5):215-8. PubMed ID: 473422
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nontraumatic aortic blood flow sensing by use of an ultrasonic esophageal probe.
    Daigle RE; Miller CW; Histand MB; McLeod FD; Hokanson DE
    J Appl Physiol; 1975 Jun; 38(6):1153-60. PubMed ID: 1141132
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonic transesophageal measurement of hemodynamic parameters in humans.
    Wells MK; Histand MB; Reeves JT; Sodal IE; Adamson HP
    ISA Trans; 1979; 18(1):57-61. PubMed ID: 457368
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Descending aortic blood flow and cardiac output: a clinical and experimental study of continuous oesophageal echo-Doppler flowmetry.
    Odenstedt H; Aneman A; Oi Y; Svensson M; Stenqvist O; Lundin S
    Acta Anaesthesiol Scand; 2001 Feb; 45(2):180-7. PubMed ID: 11167163
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow in the thoracic aorta.
    Farthing S; Peronneau P
    Cardiovasc Res; 1979 Nov; 13(11):607-20. PubMed ID: 519664
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Aortic flow measurement by transesophageal Doppler effect].
    Cathignol D; Lavandier B; Muchada R
    Ann Fr Anesth Reanim; 1985; 4(5):438-43. PubMed ID: 2934010
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Blood flow velocity and pulsatile diameter changes in the fetal descending aorta: a longitudinal study.
    Stale H; Gennser G; Marsál K
    Am J Obstet Gynecol; 1990 Jul; 163(1 Pt 1):26-9. PubMed ID: 2197869
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The time-distance recorder as a means of improving the accuracy of fetal blood flow measurements.
    Struyk PC; Pijpers L; Wladimiroff JW; Lotgering FK; Tonge M; Bom N
    Ultrasound Med Biol; 1985; 11(1):71-7. PubMed ID: 3892819
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A combined transcutaneous pulse-echo and Doppler ultrasonic technique for the measurement of brachial artery peak velocity.
    Moss S; Bennett D
    J Biomed Eng; 1979 Jan; 1(1):5-11. PubMed ID: 537332
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aortic Doppler velocity measurement and cardiac function in the fetal lamb.
    Thompson RS; Trudinger BJ; Reed VD; Turner AJ
    Ultrasound Med Biol; 1994; 20(9):893-902. PubMed ID: 7886849
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasonic measurement of aortic and umbilical blood flow in the human fetus.
    Van Lierde M; Oberweis D; Thomas K
    Obstet Gynecol; 1984 Jun; 63(6):801-5. PubMed ID: 6728361
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-invasive assessment of changes in aortic blood velocity and its derivatives with exercise in normal subjects by Doppler ultrasound.
    Salmasi AM; Salmasi SN; Doré C; Nicolaides AN
    J Cardiovasc Surg (Torino); 1987; 28(3):321-7. PubMed ID: 3294852
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasonic measurement of human fetal blood flow.
    Eik-Nes SH; Marsal K; Brubakk AO; Kristofferson K; Ulstein M
    J Biomed Eng; 1982 Jan; 4(1):28-36. PubMed ID: 7078139
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Blood flow in the fetal descending aorta; intrinsic factors affecting fetal blood flow, i.e. fetal breathing movements and cardiac arrhythmia.
    Marsál K; Lindblad A; Lingman G; Eik-Nes SH
    Ultrasound Med Biol; 1984; 10(3):339-48. PubMed ID: 6464220
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A venous pulse Doppler catheter-tip flowmeter for measuring arterial blood velocity, flow, and diameter in deep arteries.
    Nealeigh RC; Miller CW
    ISA Trans; 1976; 15(1):84-7. PubMed ID: 133084
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Aortic diameter pulse waves and blood flow velocity in the small, for gestational age, fetus.
    Stale H; Marsál K; Gennser G; Benthin M; Dahl P; Lindström K
    Ultrasound Med Biol; 1991; 17(5):471-8. PubMed ID: 1962348
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radial blood velocity in the canine aortic arch.
    Wells MK; McMullen RF; Histand MB; Miller CW
    Biomed Sci Instrum; 1980 Apr 21-22; 16():75-9. PubMed ID: 6447519
    [No Abstract]   [Full Text] [Related]  

  • 18. Measurement of instantaneous blood-flow velocity in the human aorta using pulsed Doppler ultrasound.
    Gisvold SE; Brubakk AO
    Cardiovasc Res; 1982 Jan; 16(1):26-33. PubMed ID: 7060059
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new perivascular multi-element pulsed Doppler ultrasound system for in vivo studies of velocity fields and turbulent stresses in large vessels.
    Nygaard H; Hasenkam JM; Pedersen EM; Kim WY; Paulsen PK
    Med Biol Eng Comput; 1994 Jan; 32(1):55-62. PubMed ID: 8182963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Trancutaneous determination of aortic blood-flow velocities in man.
    Huntsman LL; Gams E; Johnson CC; Fairbanks E
    Am Heart J; 1975 May; 89(5):605-12. PubMed ID: 123407
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.