These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 4736867)

  • 1. Indirect blood-pressure measurement in infants: a comparison of four methods in four limbs.
    Sadove MS; Schmidt G; Wu HH; Katz D
    Anesth Analg; 1973; 52(4):682-9. PubMed ID: 4736867
    [No Abstract]   [Full Text] [Related]  

  • 2. Ultrasonic measurement of infant blood pressure.
    Massie HL; Ziedonis JG; Black I
    Med Instrum; 1973; 7(4):240-4. PubMed ID: 4746840
    [No Abstract]   [Full Text] [Related]  

  • 3. Variability of four limb blood pressure in normal neonates.
    Crossland DS; Furness JC; Abu-Harb M; Sadagopan SN; Wren C
    Arch Dis Child Fetal Neonatal Ed; 2004 Jul; 89(4):F325-7. PubMed ID: 15210667
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic ultrasonic measurement of brachial and popliteal blood pressures for health testing.
    Caceres CA; Siebelt B; Hochberg HM
    Med Ann Dist Columbia; 1973 May; 42(5):234-7. PubMed ID: 4512991
    [No Abstract]   [Full Text] [Related]  

  • 5. Systolic blood pressure measurement in the newborn infant with the transcutaneous Doppler method.
    Kirkland RT; Kirkland JL
    J Pediatr; 1972 Jan; 80(1):52-6. PubMed ID: 5016352
    [No Abstract]   [Full Text] [Related]  

  • 6. Automatic ultrasonic blood pressure measurement in children: a feasibility study.
    Hochberg HM
    Curr Ther Res Clin Exp; 1971 Jul; 13(7):473-81. PubMed ID: 5000302
    [No Abstract]   [Full Text] [Related]  

  • 7. Calf blood pressure: clinical implications and correlations with arm blood pressure in infants and young children.
    Crapanzano MS; Strong WB; Newman IR; Hixon RL; Casal D; Linder CW
    Pediatrics; 1996 Feb; 97(2):220-4. PubMed ID: 8584381
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of brachial and calf blood pressures in infants.
    Axton SE; Smith LF; Bertrand S; Dy E; Liehr P
    Pediatr Nurs; 1995; 21(4):323-6. PubMed ID: 7644278
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison between brachial blood pressures obtained by aneroid sphygmomanometer and central aortic pressures: factors affecting the measurements].
    Kayrak M; Ulgen MS; Yazici M; Demir K; Doğan Y; Koç F; Zengin K; Ari H
    Turk Kardiyol Dern Ars; 2008 Jun; 36(4):239-46. PubMed ID: 18765967
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new oscillometry-based method for estimating the brachial arterial compliance under loaded conditions.
    Liu SH; Wang JJ; Huang KS
    IEEE Trans Biomed Eng; 2008 Oct; 55(10):2463-70. PubMed ID: 18838372
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An optical oscillometric method for neonatal and premature infant blood pressure monitoring.
    Roeder RA; Geddes LA
    Adv Neonatal Care; 2009 Apr; 9(2):77-81. PubMed ID: 19363328
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Determination of blood pressure in lower and upper limbs in screening for peripheral arteriopathies].
    Salmistraro G; Cappelletto ML; Zulian P; Andreozzi GM
    Minerva Cardioangiol; 1998 Sep; 46(9):301-3. PubMed ID: 10021853
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of direct and indirect methods of measurement of arterial blood pressure in man.
    Ulrych M; Burianová B; Hornych A; Mydlík M; Dousa T; Hejl Z
    Cor Vasa; 1966; 8(2):77-88. PubMed ID: 5939683
    [No Abstract]   [Full Text] [Related]  

  • 14. On the indirect determination of systolic and diastolic blood pressure in the newborn infant. A simple bedside electronic oscillometer.
    Nelson NM
    Pediatrics; 1968 Dec; 42(6):934-42. PubMed ID: 5726386
    [No Abstract]   [Full Text] [Related]  

  • 15. Transcutaneous measurement of blood flow by ultrasound.
    Yao ST; Needham TN; Ashton JP
    Biomed Eng; 1970 May; 5(5):230-3. PubMed ID: 5422361
    [No Abstract]   [Full Text] [Related]  

  • 16. Comparison of upper arm and calf oscillometric blood pressure measurement in preterm infants.
    Kunk R; McCain GC
    J Perinatol; 1996; 16(2 Pt 1):89-92. PubMed ID: 8732553
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Indirect measurement of blood pressure in neonates and infants utilizing an automatic noninvasive oscillometric monitor.
    Friesen RH; Lichtor JL
    Anesth Analg; 1981 Oct; 60(10):742-5. PubMed ID: 7197478
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Determination of blood pressure by 3 indirect methods in children aged 6 days to 2 years].
    Swidzińska S
    Pediatr Pol; 1986 Oct; 61(10):635-9. PubMed ID: 3588096
    [No Abstract]   [Full Text] [Related]  

  • 19. Comparison of three measures of the ankle-brachial blood pressure index in a general population.
    Pan CR; Staessen JA; Li Y; Wang JG
    Hypertens Res; 2007 Jun; 30(6):555-61. PubMed ID: 17664860
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement.
    Ursino M; Cristalli C
    IEEE Trans Biomed Eng; 1996 Aug; 43(8):761-78. PubMed ID: 9216149
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.