These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

55 related articles for article (PubMed ID: 4738832)

  • 1. [On the mechanism of platelet retention by glass bead column. The platelet adhesiveness on glass head columns (Hellem II)].
    Tsukada T; Ogawa T
    Rinsho Ketsueki; 1973 Jul; 14(7):777-84. PubMed ID: 4738832
    [No Abstract]   [Full Text] [Related]  

  • 2. Platelet adhesion and aggregation in the glass bead column method (Hellem-II): a scanning electron microscope study.
    Hattori A; Ito S; Tsukada T; Koike K; Matsuoka M
    Arch Histol Jpn; 1974 Mar; 36(4):323-37. PubMed ID: 4600201
    [No Abstract]   [Full Text] [Related]  

  • 3. Mechanisms of platelet retention in the collagen-coated-bead column.
    Kaneko M; Cuyun-Lira O; Takafuta T; Suzuki-Inoue K; Satoh K; Ohtsuki K; Ohnishi M; Arai M; Yatomi Y; Ozaki Y
    J Lab Clin Med; 2003 Oct; 142(4):258-67. PubMed ID: 14625532
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Evaluation of blood platelet retention by a glass bead column. (2). Time lapse after specimen collection and microfractionation method].
    Nozawa T; Nagaoka T; Tsukada R
    Rinsho Byori; 1974 Oct; 22(10 Suppl):97. PubMed ID: 4476011
    [No Abstract]   [Full Text] [Related]  

  • 5. [The measurement of platelet adhesiveness using glass bead column (author's transl)].
    Yoshino K; Odake K; Murakami M
    Rinsho Ketsueki; 1974 Mar; 15(3):284-90. PubMed ID: 4859162
    [No Abstract]   [Full Text] [Related]  

  • 6. [Determination of blood platelet adhesion and aggregation by using glass bead filters: (III). Relationship between hemolysis, retention rate and a concluding remark].
    Odajima H; Sekikawa H; Kurotaki E; Ichinose Y; Miura Y
    Rinsho Byori; 1974 Oct; 22(10 Suppl):96. PubMed ID: 4476010
    [No Abstract]   [Full Text] [Related]  

  • 7. Platelet adhesiveness in coronary heart disease.
    Mukherjee M; Desai BH
    Indian Heart J; 1993; 45(3):195-8. PubMed ID: 8314273
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of platelet retention in glass bead columns.
    Meyer D
    Adv Exp Med Biol; 1972; 34():263-9. PubMed ID: 4642536
    [No Abstract]   [Full Text] [Related]  

  • 9. Non-thrombogenicity of clean glass revealed by native whole blood assay in bead columns.
    Bergeron JA; DiNovo JM; Razzano AF; Dodds WJ
    Thromb Haemost; 1983 Dec; 50(4):814-20. PubMed ID: 6665762
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Methodology of obtaining and digital processing of adhesive cells].
    Vasin SL; Titushkin IA; Prokopenko RA; Rozanova IB; Sevast'ianov VI
    Med Tekh; 1998; (1):6-9. PubMed ID: 9560811
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reversible decrease in platelet retention by glass bead columns (adhesiveness) induced by disturbing the blood.
    Coller BS; Zucker MB
    Proc Soc Exp Biol Med; 1971 Mar; 136(3):769-71. PubMed ID: 5555369
    [No Abstract]   [Full Text] [Related]  

  • 12. Integrin receptors and platelet adhesion to synthetic surfaces.
    Goodman SL; Cooper SL; Albrecht RM
    J Biomed Mater Res; 1993 May; 27(5):683-95. PubMed ID: 8390998
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Determination of thrombocyte adhesiveness (retention) using glass beads].
    Smolianitskiĭ AIa; Detinkina GN; Dynkina IM
    Lab Delo; 1985; (2):90-3. PubMed ID: 2581034
    [No Abstract]   [Full Text] [Related]  

  • 14. A study of platelet adhesiveness in leprosy.
    Parvez M; Sharda DP; Jain AK; Bhargava NC; Misra SN
    Lepr India; 1979 Jul; 51(3):363-8. PubMed ID: 513652
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Some factors influencing platelet retention in glass bead columns including the influence of plastics.
    Bowie EJ; Owen CA
    Am J Clin Pathol; 1971 Oct; 56(4):479-83. PubMed ID: 5113400
    [No Abstract]   [Full Text] [Related]  

  • 16. Platelet adhesion in bleeder swine measured by glass bead column.
    Cooper RG; Cornell CN; Muhrer ME; Garb S
    Tex Rep Biol Med; 1969; 27(4):955-61. PubMed ID: 5310287
    [No Abstract]   [Full Text] [Related]  

  • 17. Adhesion, spreading, and aggregation of platelets in flowing blood and the reliability of the retention test Homburg.
    Krischek B; Morgenstern E; Mestres P; Klinkhardt U; Brannath W; Wieding U; Nemeh A; Heinrich W; Schenk J; Wenzel T; Wenzel E
    Semin Thromb Hemost; 2005; 31(4):449-57. PubMed ID: 16149023
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deficiency of platelet glass bead adhesion and platelet membrane glycoprotein IV (CD36) in Duchenne muscular dystrophy.
    Maurin N; Forst J; Leithe H; Forst R
    Thromb Haemost; 1998 May; 79(5):1067. PubMed ID: 9609256
    [No Abstract]   [Full Text] [Related]  

  • 19. Retention of platelets by glass beads. Variation with the age of the individual.
    Bucher U; Robert Y; Riedwyl H
    Thromb Diath Haemorrh; 1973 Jun; 29(3):671-8. PubMed ID: 4761833
    [No Abstract]   [Full Text] [Related]  

  • 20. Platelet adhesiveness in von Willebrand's disease. A study with a new modification of the glass bead filter method.
    Hellem AJ
    Scand J Haematol; 1970; 7(5):374-82. PubMed ID: 5312568
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.