These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
109 related articles for article (PubMed ID: 4741374)
1. A modified pinhole camera method for investigation of x-ray tube focal spots. Arnold BA; Bjärngard BE; Klopping JC Phys Med Biol; 1973 Jul; 18(4):540-9. PubMed ID: 4741374 [No Abstract] [Full Text] [Related]
2. X-ray tube focal spot sizes: comprehensive studies of their measurement and effect of measured size in angiography. Doi K; Loo LN; Chan HP Radiology; 1982 Jul; 144(2):383-93. PubMed ID: 7089295 [TBL] [Abstract][Full Text] [Related]
3. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector. Russo P; Mettivier G Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943 [TBL] [Abstract][Full Text] [Related]
4. Alignment of x-ray tube focal spots for spectral measurement. Nishizawa K; Maekoshi H; Kamiya Y; Kobayashi Y; Ohara K; Sakuma S Med Phys; 1982; 9(2):284-7. PubMed ID: 7087916 [TBL] [Abstract][Full Text] [Related]
5. Measurement of the focal spot size of diagnostic x-ray tubes--a comparison of pinhole and resolution methods. Robinson A; Grimshaw GM Br J Radiol; 1975 Jul; 48(571):572-80. PubMed ID: 1148590 [TBL] [Abstract][Full Text] [Related]
6. A circular test pattern for evaluating x-ray tube focal spots. Zeman GH; Rao GU; Doyle RJ AJR Am J Roentgenol; 1976 Jun; 126(6):1239-45. PubMed ID: 179388 [TBL] [Abstract][Full Text] [Related]
8. Effective size of the transverse dimension of x-ray-tube focal spots. Prasad SC; Hendee WR Med Phys; 1977; 4(3):235-8. PubMed ID: 882058 [TBL] [Abstract][Full Text] [Related]
9. Intensity distribution, modulation transfer function, and the effective dimension of a line-focus x-ray focal spot. Prasad SC; Hendee WR; Carson PL Med Phys; 1976; 3(4):217-23. PubMed ID: 958167 [TBL] [Abstract][Full Text] [Related]
10. Pinhole cameras: artifacts modifications, and recording of pinhole images of screen-film systems. Gray JE; Trefler M Radiol Technol; 1980; 52(3):277-82. PubMed ID: 7280211 [TBL] [Abstract][Full Text] [Related]
11. Effective dimensions of roentgen tube focal spots based on measurement of the modulation transfer function. Rao GU; Bates LM Acta Radiol Ther Phys Biol; 1970 Aug; 9(4):362-8. PubMed ID: 5458185 [No Abstract] [Full Text] [Related]
12. Focal-spot measurement: comparison of slit, pinhole, and star resolution pattern techniques. Everson JD; Gray JE Radiology; 1987 Oct; 165(1):261-4. PubMed ID: 3628780 [TBL] [Abstract][Full Text] [Related]
13. [Practical experiences in the determination of tube voltage using the Ardran-Crooks cassette]. Ewen K; Rösner W Rontgenblatter; 1984 Jan; 37(1):21-5. PubMed ID: 6701432 [TBL] [Abstract][Full Text] [Related]
14. Determination of x-ray tube focal spot position. Kubota H; Ozaki Y; Matsumoto M; Kanamori H Med Phys; 1993; 20(4):1029-31. PubMed ID: 8413010 [TBL] [Abstract][Full Text] [Related]
15. A highly accurate focal spot camera--laboratory and field model. Roeck WW; Milne EN Radiology; 1978 Jun; 127(3):779-83. PubMed ID: 663178 [TBL] [Abstract][Full Text] [Related]
16. The relationship of the radiant intensity distribution of focal spots to resolution. Bernstein H; Bergeron RT; Klein DJ Radiology; 1974 May; 111(2):427-31. PubMed ID: 4818984 [No Abstract] [Full Text] [Related]
17. Effects of focal spot intensity distribution and collimator width in reconstructive x-ray tomography. Prasad SC Med Phys; 1979; 6(3):229-32. PubMed ID: 470849 [TBL] [Abstract][Full Text] [Related]
18. [The influence of x-ray tube voltage on the exposure of x-ray films (author's transl)]. Angerstein W; Wolf M Radiol Diagn (Berl); 1975; 16(3):437-9. PubMed ID: 1215510 [No Abstract] [Full Text] [Related]
19. Effects of x-ray tube current and voltage on effective focalspot size. Chaney EL; Hendee WR Med Phys; 1974; 1(3):141-7. PubMed ID: 4418740 [No Abstract] [Full Text] [Related]
20. New device for accurate measurement of the x-ray intensity distribution of x-ray tube focal spots. Doi K; Fromes B; Rossmann K Med Phys; 1975; 2(5):268-73. PubMed ID: 1186633 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]