These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 4749589)

  • 1. Low-temperature response of LiF-Teflon dosimeters.
    Milvy P; Orton CG; Seibert J; Kaufman LA
    Radiat Res; 1973 Nov; 56(2):232-7. PubMed ID: 4749589
    [No Abstract]   [Full Text] [Related]  

  • 2. Fading of LiF-Teflon dosimeters used in identification badges.
    Johnson TL; Robinson RL; Luersen RB
    Health Phys; 1977 Jan; 32(1):31-2. PubMed ID: 838587
    [No Abstract]   [Full Text] [Related]  

  • 3. Correct handling of thermoluminescent LiF:teflon dosimeters.
    Blackman TE; Johns TF; Preston HE; Mason EW; Marshall TO; Shaw KB
    Br J Radiol; 1974 Jun; 47(558):361-3. PubMed ID: 4835214
    [No Abstract]   [Full Text] [Related]  

  • 4. LiF and CaF2: Dy thermoluminescent dosimeters.
    Tsuda M; Ohizumi Y; Mori T
    Strahlentherapie; 1980; 156(10):708-13. PubMed ID: 7434378
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Light sensitivity of LiF thermoluminescent dosimeters.
    Freeswick DC; Shambon A
    Health Phys; 1970 Jul; 19(1):65. PubMed ID: 5513547
    [No Abstract]   [Full Text] [Related]  

  • 6. Thermoluminescent response of LiF dosimeters to fast neutrons produced with 25--60-MeV protons on thick beryllium target.
    Momeni MH
    Health Phys; 1974 Aug; 27(2):217-9. PubMed ID: 4443265
    [No Abstract]   [Full Text] [Related]  

  • 7. Reduction of abnormal background levels in LiF-teflon thermoluminescent dosimeters.
    Robertson ME; Gilboy WB
    Int J Appl Radiat Isot; 1972 Sep; 23(9):439-40. PubMed ID: 5079060
    [No Abstract]   [Full Text] [Related]  

  • 8. A study of two kinds of thermoluminescent dosimeters; CaF2:Tm and CaSO4:Dy in LiF.
    Tsuda M; Katsurada T; Ando F; Kawamata F; Yunogami S
    Strahlentherapie; 1982 Sep; 158(9):563-9. PubMed ID: 7147279
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dependence of LiF TLD-100 response on temperature during exposure.
    Sunta CM; Mazzaro AC; Sordi GM; Watanabe S
    Health Phys; 1976 Mar; 30(3):309-10. PubMed ID: 1254484
    [No Abstract]   [Full Text] [Related]  

  • 10. Optimum integrating peroid for "unannealed" LiF thermo-luminescent dosimeters.
    Johnson TL
    Health Phys; 1974 Aug; 27(2):220-2. PubMed ID: 4443267
    [No Abstract]   [Full Text] [Related]  

  • 11. The response of TLD-700 thermoluminescent dosimeters to protons and alpha-particles.
    Jähnert B
    Health Phys; 1972 Jul; 23(1):112-4. PubMed ID: 5077568
    [No Abstract]   [Full Text] [Related]  

  • 12. Dosimetry at interfaces. Theoretical analysis and measurements by means of thermoluminescent LiF at plane interfaces between a low Z-material and Al, Cu, Sn or Pb irradiated with 100 to 200 kV roentgen radiation.
    Carlsson GA
    Acta Radiol Suppl; 1973; 332():1-64. PubMed ID: 4519462
    [No Abstract]   [Full Text] [Related]  

  • 13. Thermoluninescenct in LiF: sensitization useful at low exposures.
    Mayhugh MR; Fullerton GD
    Health Phys; 1975 Mar; 28(3):297-9. PubMed ID: 1112729
    [No Abstract]   [Full Text] [Related]  

  • 14. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
    Al-Haj A; Lagarde C; Mahyoub F
    Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
    [TBL] [Abstract][Full Text] [Related]  

  • 15. DAMAGE EFFECTS IN CAF2:MN AND LIF THERMOLUMINESCENT DOSIMETERS.
    MARRONE MJ; ATTIX FH
    Health Phys; 1964 Jun; 10():431-6. PubMed ID: 14170714
    [No Abstract]   [Full Text] [Related]  

  • 16. Response of LiF to fast neutrons.
    McGinley PH
    Health Phys; 1972 Jul; 23(1):105-6. PubMed ID: 5077565
    [No Abstract]   [Full Text] [Related]  

  • 17. The energy response of personal dosimeters.
    Johns TF
    Health Phys; 1976 Aug; 31(2):185. PubMed ID: 972064
    [No Abstract]   [Full Text] [Related]  

  • 18. Calibration of LiF teflon rods for internal LiF beta-ray dosimetry.
    Greitz U; Rudén BI
    Phys Med Biol; 1972 Mar; 17(2):193-7. PubMed ID: 5072543
    [No Abstract]   [Full Text] [Related]  

  • 19. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.
    Moscovitch M; St John TJ; Cassata JR; Blake PK; Rotunda JE; Ramlo M; Velbeck KJ; Luo LZ
    Radiat Prot Dosimetry; 2006; 119(1-4):248-54. PubMed ID: 16835277
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New system to realize a reliable thermal contact in TLD-system.
    Ghoos LH; Mertens E; Boulenger RR
    Health Phys; 1975 Nov; 29(5):785-6. PubMed ID: 1193894
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.