These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 4773143)

  • 41. Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal contents and associated histologic findings.
    Betts F; Wright T; Salvati EA; Boskey A; Bansal M
    Clin Orthop Relat Res; 1992 Mar; (276):75-82. PubMed ID: 1537178
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [On the stress state of bone cement fixing a hip joint prosthesis (author's transl)].
    Stern J
    Arch Orthop Unfallchir; 1977 Jun; 88(3):309-12. PubMed ID: 889525
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Balneo-rehabilitation following hip joint replacement by the Austin-Moore or McKee-Farrar prosthesis].
    Lutomski B; Fiszer H; Wejselog A; Zappa M
    Chir Narzadow Ruchu Ortop Pol; 1973 Apr; 38(4):451-6. PubMed ID: 4755331
    [No Abstract]   [Full Text] [Related]  

  • 44. [Secondary total replacement of the hip with a McKee Farrar prosthesis].
    Wejsflog A; Zappa M; Lutomski B
    Chir Narzadow Ruchu Ortop Pol; 1974; 39(3):339-47. PubMed ID: 4846370
    [No Abstract]   [Full Text] [Related]  

  • 45. Lessons learned from loosening of the McKee-Farrar metal-on-metal total hip replacement.
    Zahiri CA; Schmalzried TP; Ebramzadeh E; Szuszczewicz ES; Salib D; Kim C; Amstutz HC
    J Arthroplasty; 1999 Apr; 14(3):326-32. PubMed ID: 10220187
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Total hip replacement by the method of McKee-Farrar.
    Haraldsson S
    Acta Orthop Scand; 1971; 42(5):448-9. PubMed ID: 5144006
    [No Abstract]   [Full Text] [Related]  

  • 47. [Evaluation of loosening of different total hip models and neck lengths (author's transl)].
    Tönnis D; Asai H
    Arch Orthop Unfallchir; 1976 Nov; 86(3):317-32. PubMed ID: 1008730
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Contribution to the technique of acetabular implantation in total hip arthroplasty (author's transl)].
    Dick W; Morscher E
    Arch Orthop Unfallchir; 1975 Oct; 83(2):215-20. PubMed ID: 1191117
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Loosening of the acetabular implant after replacement of the hip-joint due to age-related loss of bone structure (author's transl)].
    Münzenberg KJ; Dennert R
    Z Orthop Ihre Grenzgeb; 1975 Oct; 113(5):947-51. PubMed ID: 1202802
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Endoprostheses of the hip with surface structured anchorage shafts. Results of static loading experiments (author's transl)].
    Niederer PG; Chiquet C; Eulenberger J
    Unfallheilkunde; 1978 Apr; 81(4):205-10. PubMed ID: 636081
    [No Abstract]   [Full Text] [Related]  

  • 51. [Contraindications for total hip prosthesis (author's transl)].
    Schellmann WD; Erdmann H; Klemm K
    Arch Orthop Unfallchir; 1974; 80(3):257-63. PubMed ID: 4614768
    [No Abstract]   [Full Text] [Related]  

  • 52. [Deterioration of the acetabulum of the Charnley total hip prosthesis (author's transl)].
    Bonvallet JM; Dautry P
    Chirurgie; 1978; 104(6):488-91. PubMed ID: 747954
    [No Abstract]   [Full Text] [Related]  

  • 53. Twenty-year results of McKee-Farrar versus Charnley prosthesis.
    Jacobsson SA; Djerf K; Wahlström O
    Clin Orthop Relat Res; 1996 Aug; (329 Suppl):S60-8. PubMed ID: 8769323
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Long-term results of 2 continuous series of total hip prostheses of the McKee-Farrar metallo-metal type and the Charnley metallo-plastic type].
    Cabitza P; Percudani W
    Arch Sci Med (Torino); 1979; 136(1):45-50. PubMed ID: 464797
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [A new hip milling machine for preparation of the hip acetabulum for total hip prothesis (author's transl)].
    Weigand H
    Arch Orthop Unfallchir; 1976 Aug; 85(3):299-302. PubMed ID: 949289
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Total replacement of the hip by the McKee-Farrar prosthesis. A preliminary report of 81 cases.
    Langenskiöld A; Salenius P
    Clin Orthop Relat Res; 1970; 72():104-5. PubMed ID: 5459773
    [No Abstract]   [Full Text] [Related]  

  • 57. Observations at the articular surface of hip prostheses: an analytical electron microscopy study on wear and corrosion.
    Koerten HK; Onderwater JJ; Koerten EW; Bernoski FP; Nelissen RG
    J Biomed Mater Res; 2001 Mar; 54(4):591-6. PubMed ID: 11426605
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Progressive bilateral pelvic osteolysis in a patient with McKee-Farrar metal-metal total hip prostheses.
    Szuszczewicz ES; Schmalzried TP; Petersen TD
    J Arthroplasty; 1997 Oct; 12(7):819-24. PubMed ID: 9355013
    [TBL] [Abstract][Full Text] [Related]  

  • 59. In vivo corrosion of cobalt-chromium and titanium wear particles.
    Shahgaldi BF; Heatley FW; Dewar A; Corrin B
    J Bone Joint Surg Br; 1995 Nov; 77(6):962-6. PubMed ID: 7593115
    [TBL] [Abstract][Full Text] [Related]  

  • 60. The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium.
    Daniel J; Ziaee H; Salama A; Pradhan C; McMinn DJ
    J Bone Joint Surg Br; 2006 Apr; 88(4):443-8. PubMed ID: 16567776
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.