These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 4775005)

  • 1. Percutaneous removal of intravascular foreign bodies by the snare technique.
    Enge I; Flatmark A
    Acta Radiol Diagn (Stockh); 1973 Nov; 14(6):747-54. PubMed ID: 4775005
    [No Abstract]   [Full Text] [Related]  

  • 2. Percutaneous removal of a fractured and extruded telectronics accufix atrial retention wire: new approach preserving pacing function.
    Saito H; Zuguchi M; Miura M; Shinozaki S; Hata M; Tabayashi K
    AJR Am J Roentgenol; 1996 Nov; 167(5):1334-6. PubMed ID: 8911207
    [No Abstract]   [Full Text] [Related]  

  • 3. Percutaneous removal of ventricular pacemaker electrodes using a Dormier basket.
    Foster CJ; Brownlee WC
    Int J Cardiol; 1988 Nov; 21(2):127-34. PubMed ID: 3066762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Removal of a fractured retention wire of an Accufix "J" pacemaker lead with an Amplatz goose neck snare.
    Saibil EA
    J Vasc Interv Radiol; 1996; 7(3):367-9. PubMed ID: 8761813
    [No Abstract]   [Full Text] [Related]  

  • 5. [A snare device for removal of foreign bodies left after percutaneous transluminal angioplasty].
    Andersen PE
    Ugeskr Laeger; 2001 Aug; 163(33):4402-3. PubMed ID: 11521580
    [No Abstract]   [Full Text] [Related]  

  • 6. Successful removal of a foreign body from the caval vein by use of endo-myocardial bioptome.
    Kurita A; Kanazawa M; Kanie T; Kimura E; Nakayama R
    Jpn Heart J; 1972 Sep; 13(5):464-9. PubMed ID: 4539429
    [No Abstract]   [Full Text] [Related]  

  • 7. Fixed intravascular foreign bodies: a new method for removal.
    Grabenwoeger F; Dock W; Pinterits F; Appel W
    Radiology; 1988 May; 167(2):555-6. PubMed ID: 3282265
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Percutaneous extraction of intravascular foreign bodies: a series of 38 cases].
    Mainar V; Picó Aracil F; Bordes P; Ruiz Ros JA; Campos Peris JV; Marín F
    Rev Esp Cardiol; 1996 Jan; 49(1):41-7. PubMed ID: 8685511
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of a coronary guiding catheter to direct a snare in removal of a retained catheter fragment.
    Mehan VK; Lokhandwala YY; Kale PA
    Cathet Cardiovasc Diagn; 1990 Dec; 21(4):294-5. PubMed ID: 2276207
    [No Abstract]   [Full Text] [Related]  

  • 10. Percutaneous extraction of an abandoned coiled pacing lead.
    Lickfett L; Jung W; Pizzulli L; Wolpert C; Lüderitz B
    Pacing Clin Electrophysiol; 1999 Jul; 22(7):1100-2. PubMed ID: 10456643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transfemoral removal of a chronically implanted pacemaker lead: report of a case.
    Cope C; Larrieu AJ; Isaacson CS; Wolk LA; Ghosh SC; Rothkopf B
    Ann Thorac Surg; 1986 Sep; 42(3):329-30. PubMed ID: 3753082
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Retrieval of lost catheters by a myocardial biopsy catheter device.
    Bashour TT; Banks T; Cheng TO
    Chest; 1974 Oct; 66(4):395-6. PubMed ID: 4415618
    [No Abstract]   [Full Text] [Related]  

  • 13. Percutaneous removal of catheter emboli.
    Miller RE; Ng AC; Dormire RD
    JAMA; 1970 Oct; 214(3):589-90. PubMed ID: 5469032
    [No Abstract]   [Full Text] [Related]  

  • 14. Percutaneous extraction of a fractured, exposed atrial "J" lead retention wire.
    Caudill CC; Clinch B; Krueger SK; Gard JR; Turk KT; Wilson CS
    Cathet Cardiovasc Diagn; 1996 Mar; 37(3):342-6. PubMed ID: 8974822
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous removal of transvenous pacing lead perforating the heart, pericardium, and pleura.
    Deutsch LS; Dang H; Brandon JC; Ott R; Allen B; Futerman C
    AJR Am J Roentgenol; 1991 Mar; 156(3):471-3. PubMed ID: 1899740
    [No Abstract]   [Full Text] [Related]  

  • 16. Percutaneous closure of the inadvertent subclavian artery cannulation during pacemaker implantation.
    Chen X; Bai J; Han F; Zhou D; Su Y
    Cardiol J; 2017; 24(4):452-454. PubMed ID: 28831782
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous extraction of a severed and frayed permanent pacing lead.
    Sochman J; Bytesnik J; Skalsky I; Peregrin JH
    Pacing Clin Electrophysiol; 2004 Mar; 27(3):412-4. PubMed ID: 15009876
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Percutaneous removal of a peripherally inserted central catheter remnant using cardiac catheterization.
    Chen CC; Liang CD; Huang CF; Chung MY
    Pediatr Int; 2006 Aug; 48(4):430-2. PubMed ID: 16911095
    [No Abstract]   [Full Text] [Related]  

  • 19. Percutaneous retrieval of a broken catheter from the left atrium in an adult.
    Ramondo AB; Favero L; Chioin R
    J Interv Cardiol; 2002 Oct; 15(5):417-9. PubMed ID: 12440189
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The nonsurgical retrieval of intracardiac foreign bodies--an international survey.
    Bloomfield DA
    Cathet Cardiovasc Diagn; 1978; 4(1):1-14. PubMed ID: 647770
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.