These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 4775005)

  • 21. [Transvenous removal of a pacemaker electrode incarcerated in the atrial septum during implantation].
    Sehnert W; Keimer P
    Med Welt; 1983 Jul; 34(27):775-7. PubMed ID: 6888251
    [No Abstract]   [Full Text] [Related]  

  • 22. The use of pigtail catheters for retrieval of foreign bodies from the cardiovascular system.
    Auge JM; Oriol A; Serra C; Crexells C
    Cathet Cardiovasc Diagn; 1984; 10(6):625-8. PubMed ID: 6391687
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Percutaneous removal of intracardiac catheter fragment: unique internal jugular venous approach.
    Glatter TR; Scott CA; Early G
    Am Heart J; 1984 Aug; 108(2):408-10. PubMed ID: 6464977
    [No Abstract]   [Full Text] [Related]  

  • 24. [Percutaneous extraction of a fragment of a central venous catheter from the right cardiac cavity].
    Anguissola GB; Lovaria A; Cristofori GB; Petrini PL; Saccheri S; Lubatti L
    Minerva Anestesiol; 1986; 52(1-2):31-4. PubMed ID: 3736911
    [No Abstract]   [Full Text] [Related]  

  • 25. Intravascular foreign bodies: percutaneous retrieval.
    Uflacker R; Lima S; Melichar AC
    Radiology; 1986 Sep; 160(3):731-5. PubMed ID: 3737911
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Percutaneous extraction of centrally embolized foreign bodies: a report of 16 cases.
    Grabenwoeger F; Bardach G; Dock W; Pinterits F
    Br J Radiol; 1988 Nov; 61(731):1014-8. PubMed ID: 3208004
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Retrieval of intravascular foreign bodies with goose neck snare.
    Koseoglu K; Parildar M; Oran I; Memis A
    Eur J Radiol; 2004 Mar; 49(3):281-5. PubMed ID: 14962660
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Removal of a catheter fragment from the right atrium by a new catheterization technique.
    Leth A; Ehlers D; Jensen G; Lauridsen P
    Scand J Thorac Cardiovasc Surg; 1973; 7(2):171-4. PubMed ID: 4749617
    [No Abstract]   [Full Text] [Related]  

  • 29. Occlusion balloon catheter-assisted removal of a wedged catheter fragment without a free end from a pulmonary artery.
    Smith JC; Black MD; Smith DC
    Cardiovasc Intervent Radiol; 2009 Nov; 32(6):1308-11. PubMed ID: 19290577
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The left atrial catheter: its uses and complications.
    Leitman BS; Naidich DP; McGuinness G; McCauley DI
    Radiology; 1992 Nov; 185(2):611-2. PubMed ID: 1410383
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Percutaneous retrieval of intravascular foreign bodies].
    Cantarelli MJ; de Paola Ade A; Alves CM; Souza JA; Castello Júnior HJ; Hermann JL; Lamounier EN; Guimarães RF; Portugal OP; Martinez Filho EE
    Arq Bras Cardiol; 1993 Mar; 60(3):171-5. PubMed ID: 8250746
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrode displacement from a multipurpose Swan-Ganz catheter.
    Heiselman DE; Maxwell JS; Petno V
    Pacing Clin Electrophysiol; 1986 Jan; 9(1 Pt 1):134-6. PubMed ID: 2419844
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Internal balloon tamponade: a non-surgical method for removal of accidentally placed sheaths from the subclavian artery.
    van Dijk RB; den Heijer P; de Muinck E; Lie KI
    Cathet Cardiovasc Diagn; 1993 Aug; 29(4):325-8. PubMed ID: 8221858
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Angiographic retrieval of foreign bodies in pulmonary artery: a report of three cases.
    Ando K; Sano A; Kigami Y; Kanaoka N; Matsumoto S; Ishikura S; Okada T; Yamada K; Mayumi K; Nakatsu M
    Radiat Med; 1993; 11(2):69-74. PubMed ID: 8316647
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Percutaneous retrieval of misplaced intravascular foreign objects with the Dormia basket: an effective solution.
    Sheth R; Someshwar V; Warawdekar G
    Cardiovasc Intervent Radiol; 2007; 30(1):48-53. PubMed ID: 17031735
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Successful removal of a severed transvenous pacemaker electrode.
    Gould L; Maghazeh P; Giovanniello J
    Pacing Clin Electrophysiol; 1981 Nov; 4(6):713-5. PubMed ID: 6173861
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Percutaneous removal of intravascular foreign bodies.
    Rubinstein ZJ; Morag B; Itzchak Y
    Cardiovasc Intervent Radiol; 1982; 5(2):64-8. PubMed ID: 7105077
    [No Abstract]   [Full Text] [Related]  

  • 38. Successful retrieval of a broken intravascular ultrasound catheter tip from a coronary artery.
    Iyisoy A; Celik M; Celik T; Yuksel UC; Samedli S
    Cardiovasc Revasc Med; 2012; 13(4):238-40. PubMed ID: 22459255
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Basket removal of intraatrial catheter after liver transplantation: technical note.
    Singer J; Joyce P; Brems J
    Cardiovasc Intervent Radiol; 1989; 12(4):230-1. PubMed ID: 2513122
    [TBL] [Abstract][Full Text] [Related]  

  • 40. "Hook catheter," technique for transfemoral removal of foreign body from right side of the heart.
    Rossi P
    Am J Roentgenol Radium Ther Nucl Med; 1970 May; 109(1):101-6. PubMed ID: 5442109
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.