BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

64 related articles for article (PubMed ID: 4799643)

  • 21. A single measurement with (51)Cr-tagged red cells or (125)I-labeled human serum albumin in the prediction of fractional and whole blood volumes: an assessment of the limitations.
    Moralidis E; Papanastassiou E; Arsos G; Chilidis I; Gerasimou G; Gotzamani-Psarrakou A
    Physiol Meas; 2009 Jul; 30(7):559-71. PubMed ID: 19458409
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A comparison of Tc-99m-labeled human serum albumin and in vitro labeled red blood cells for blood pool studies.
    Atkins HL; Klopper JF; Ansari AN; Meinken G; Richards P; Srivastava SC
    Clin Nucl Med; 1980 Apr; 5(4):166-9. PubMed ID: 7371337
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Evaluation of mucociliary clearance during pulmonary ventilatory scintigraphy (99mTc-HAMM)].
    Muttini P; Fiorio P
    Arch Monaldi; 1982; 37(1-2):99-102. PubMed ID: 6229232
    [No Abstract]   [Full Text] [Related]  

  • 24. Tc-99m-labeled red blood cells for the measurement of red cell mass in newborn infants: concise communication.
    Linderkamp O; Betke K; Fendel H; Klemm J; Lorenzen K; Riegel KP
    J Nucl Med; 1980 Jul; 21(7):637-40. PubMed ID: 7391836
    [TBL] [Abstract][Full Text] [Related]  

  • 25. High specific activity technetium-99m albumin.
    Richards P; Atkins HL
    J Nucl Med; 1967 May; 8(5):396. PubMed ID: 6032729
    [No Abstract]   [Full Text] [Related]  

  • 26. [A simplified method for the production of macroaggregates using Tc 99m -labelled human serum albumin].
    Schwartz KD; Römer J; Krüger M; Finck W
    Radiobiol Radiother (Berl); 1971; 12(2):203-8. PubMed ID: 5157025
    [No Abstract]   [Full Text] [Related]  

  • 27. A new method for blood volume estimation using 99m Technetium labelled erythrocytes.
    Tawfic HN; el-Saadani AM; el-Gengehy MT; Ahmed L el-S
    J Egypt Med Assoc; 1970; 53(1):29-33. PubMed ID: 5473297
    [No Abstract]   [Full Text] [Related]  

  • 28. Radioactive excretion in human milk following administration of technetium Tc 99m macroaggregated albumin.
    Pittard WB; Merkatz R; Fletcher BD
    Pediatrics; 1982 Aug; 70(2):231-4. PubMed ID: 6212905
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Measurement of blood volume in fetal and neonatal sheep using red blood cells labelled with 99m technetium.
    Stankewytsch-Janusch B; Scroop GC; Marker JD; Seamark RF
    J Dev Physiol; 1981 Aug; 3(4):245-54. PubMed ID: 6278016
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sterilization of technetium-99m-labeled human serum albumin by filtration.
    Billinghurst MW; Westendorf BA
    J Nucl Med; 1977 Jul; 18(7):746-7. PubMed ID: 874158
    [No Abstract]   [Full Text] [Related]  

  • 31. Cardiac blood pool imaging--a clinical comparison between red blood cells labeled with 99mTc in vivo and in vitro and 99mTc-labeled human serum albumin.
    Dahlström JA; Carlsson S; Lilja B; Mattsson S; Pettersson C
    Nuklearmedizin; 1979; 18(6):271-3. PubMed ID: 537922
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Registration of the heart volume by external counting. Evolution of this volume during the cardiac cycle.
    Zwirn P
    J Nucl Biol Med; 1972; 16(4):231-5. PubMed ID: 4666537
    [No Abstract]   [Full Text] [Related]  

  • 33. Evaluation of blood volume determination in severe hemorrhage, using radioactive iodinated human serum albumin; a preliminary report.
    SILER VE; FULTZ CT
    Surg Forum; 1953 Oct; 4():515-8. PubMed ID: 13187331
    [No Abstract]   [Full Text] [Related]  

  • 34. [Lung scintigram test by 99mTc-MAA].
    Nakayama C; Watanabe K; Kawahira K; Kamoi I; Takahashi M
    Rinsho Hoshasen; 1976 Mar; 21(4):317-21. PubMed ID: 987352
    [No Abstract]   [Full Text] [Related]  

  • 35. [Determination of blood volume in children by means of J 131 labeled albumin].
    IMPERATO C; GIOVANNELLI G; BATTISTINI FD; LUCINI E; GHIRARDINI G
    Arch Ital Pediatr Pueric; 1958; 19(1):3-32. PubMed ID: 13535065
    [No Abstract]   [Full Text] [Related]  

  • 36. Blood volume determination, a nuclear medicine test in evolution.
    Margouleff D
    Clin Nucl Med; 2013 Jul; 38(7):534-7. PubMed ID: 23657140
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Contribution to the study of the mechanism of labelling human serum albumin (HSA) with technetium-99m.
    Zolle I; Oniciu L; Höfer R
    Int J Appl Radiat Isot; 1973 Nov; 24(11):621-6. PubMed ID: 4756230
    [No Abstract]   [Full Text] [Related]  

  • 38. [Technical considerations on the use of radiocardiography in the determination of blood volume].
    PARIGI A; GIRIVETTO F; FREGOLA G; MAROCCO F
    Minerva Nucl; 1958 Sep; 2(9):227-33. PubMed ID: 13600205
    [No Abstract]   [Full Text] [Related]  

  • 39. 62Cu-labeling of human serum albumin-dithiosemicarbazone (HSA-DTS) conjugate for regional plasma volume measurement: application of new 62Zn/62Cu generator system.
    Fujibayashi Y; Matsumoto K; Arano Y; Yonekura Y; Konishi J; Yokoyama A
    Chem Pharm Bull (Tokyo); 1990 Jul; 38(7):1946-8. PubMed ID: 2268894
    [TBL] [Abstract][Full Text] [Related]  

  • 40. High-specific-activity 99m Tc Human serum albumin.
    Eckelman WC; Meinken G; Richards P
    Radiology; 1972 Jan; 102(1):185-6. PubMed ID: 5008143
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.