These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 4891911)

  • 1. Effect of hematocrit on response characteristics in indocyanine green densitometers.
    Cropp GJ
    J Appl Physiol; 1969 Jul; 27(1):132-6. PubMed ID: 4891911
    [No Abstract]   [Full Text] [Related]  

  • 2. Calibration of densitometers for indicator dye dilution.
    Rush EC; Neutze JM; Harris EA
    Cardiovasc Res; 1977 May; 11(3):263-9. PubMed ID: 326404
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of the cardiac output determination by the direct Fick method and the dye-dilution method using indocyanine green dye and a cuvette densitometer.
    MILLER DE; GLEASON WL; McINTOSH HD
    J Lab Clin Med; 1962 Feb; 59():345-50. PubMed ID: 14473967
    [No Abstract]   [Full Text] [Related]  

  • 4. Comparison of the cardiac output measurements with electromagnetic flowmeter and dye-dilution technique in dogs, with a note on the comparison between radiocardiography and ear-dye method in man.
    Hirakawa S; Ito H; Kondo Y; Kanyama S; Watanabe I; Mori N; Hayase S
    Jpn Circ J; 1975 Apr; 39(4):393-402. PubMed ID: 123603
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of indocyanine green dye with a cuvette oximeter.
    Sekelj P; Oriol A; Anderson NM; Morch J; McGregor M
    J Appl Physiol; 1967 Jul; 23(1):114-20. PubMed ID: 5339058
    [No Abstract]   [Full Text] [Related]  

  • 6. Electronic calibration for indocyanine dye-dilution curves.
    Sullivan FJ; Mroz EA; Miller RE
    Am Heart J; 1973 Apr; 85(4):506-10. PubMed ID: 4570071
    [No Abstract]   [Full Text] [Related]  

  • 7. [Measurement of cardiac output with cardio-green].
    Messin R; Degre S; Lenaers A; van Thiel E; Denolin H
    Int Z Angew Physiol; 1966 Apr; 22(2):131-40. PubMed ID: 4861941
    [No Abstract]   [Full Text] [Related]  

  • 8. Use of dichromatic earpiece densitometry for determination of cardiac output.
    Reed JH; Wood EH
    J Appl Physiol; 1967 Sep; 23(3):373-80. PubMed ID: 4860350
    [No Abstract]   [Full Text] [Related]  

  • 9. Does indocyanine green accurately measure plasma volume early after cardiac surgery?
    Ishihara H; Okawa H; Iwakawa T; Umegaki N; Tsubo T; Matsuki A
    Anesth Analg; 2002 Apr; 94(4):781-6, table of contents. PubMed ID: 11916773
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A linear reflection densitometer for indocyanine green.
    Hoor FT; Mook GA
    Cardiovasc Res; 1969 Jul; 3(3):373-80. PubMed ID: 4898396
    [No Abstract]   [Full Text] [Related]  

  • 11. A dye densitometer for measuring cardiac output.
    Jarlov AL; Holmkjaer PM
    Med Biol Eng; 1972 Jan; 10(1):97-100. PubMed ID: 4558034
    [No Abstract]   [Full Text] [Related]  

  • 12. [Application of indicator dye dilution technic to heart diseases. Clinical use of indocyanine green by the earpiece method].
    Kimura N; Utsu N; Nakayama H; Abe T; Kasuga M
    Rinsho Byori; 1969 Aug; 17(8):639-44. PubMed ID: 4902652
    [No Abstract]   [Full Text] [Related]  

  • 13. Controlled variation of light intensity to test frequency responses of densitometers.
    Saunders KB; Feasey AW; Hoffman JI
    J Appl Physiol; 1971 Dec; 31(6):899-903. PubMed ID: 4941772
    [No Abstract]   [Full Text] [Related]  

  • 14. A linearly responding monochromatic cuvette densitometer for indocyanine green.
    Knutsen B; Lund-Johansen P; Hatletveit E
    Scand J Clin Lab Invest; 1966; 18(6):673-8. PubMed ID: 5335274
    [No Abstract]   [Full Text] [Related]  

  • 15. Quasi-simultaneous cardiac output determinations in dogs with the direct Fick method (O2 and CO2) and with the dye dilution method using a linear reflection densitometer.
    ten Hoor F; Rispens P; Buursma A; Fongers TM; Jurriƫns JM; Zijlma JA
    Pflugers Arch; 1970; 314(2):148-50. PubMed ID: 4903732
    [No Abstract]   [Full Text] [Related]  

  • 16. Cardiac output by dye dilution in the conscious rat.
    Coleman TG
    J Appl Physiol; 1974 Sep; 37(3):452-5. PubMed ID: 4606309
    [No Abstract]   [Full Text] [Related]  

  • 17. INDOCYANINE GREEN DENSITOMETRY IN FLOWING BLOOD COMPENSATED FOR BACKGROUND DYE.
    EDWARDS AW; ISAACSON J; SUTTERER WF; BASSINGTHWAIGHTE JB; WOOD EH
    J Appl Physiol; 1963 Nov; 18():1294-304. PubMed ID: 14080764
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of indocyanine green dye concentration in the extracorporeal circulation.
    Schneditz D; Mekaroonkamol P; Haditsch B; Stauber R
    ASAIO J; 2005; 51(4):376-8. PubMed ID: 16156302
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of pulmonary blood volume in dogs by radiocardiography and dye dilution.
    Ellis JH; Steele PP
    J Appl Physiol; 1974 Oct; 37(4):570-4. PubMed ID: 4606371
    [No Abstract]   [Full Text] [Related]  

  • 20. A computerised dichromatic earpiece densitometer for the measurement of cardiac output.
    Robinson PS; Crowther A; Jenkins BS; Webb-Peploe MM; Coltart DJ
    Cardiovasc Res; 1979 Jul; 13(7):420-6. PubMed ID: 385143
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.