These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 4936768)

  • 1. [Moulding of cavities and preparation stumps with heat-reversible hydrocolloid].
    Gutowski A
    ZWR; 1971 Jul; 80(14):650-3. PubMed ID: 4936768
    [No Abstract]   [Full Text] [Related]  

  • 2. Using reversible hydrocolloid impression materials.
    Wartell RL
    Compend Contin Educ Dent (Lawrenceville); 1984 Mar; 5(3):229-32, 235-8. PubMed ID: 6380925
    [No Abstract]   [Full Text] [Related]  

  • 3. Hydrocolloid: a reassessment for better dentistry.
    Engelman MA
    N Y State Dent J; 1979 Oct; 45(8):383-8. PubMed ID: 388265
    [No Abstract]   [Full Text] [Related]  

  • 4. [Studies on the accuracy of elastomeric impression materials. Part 2. Comparison of dimensional accuracy of casts made by both single polyether rubber impression and the combined reversible and irreversible hydrocolloid impression technique (author's transl)].
    Shigeto N; Inohara N; Yamada S
    Hiroshima Daigaku Shigaku Zasshi; 1978; 10(1):98-108. PubMed ID: 396327
    [No Abstract]   [Full Text] [Related]  

  • 5. Reversible agar agar hydrocolloid.
    Reed HV
    Quintessence Int; 1990 Mar; 21(3):225-9. PubMed ID: 2197671
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reversible hydrocolloid: the standard of excellence.
    Nemetz H; Tjan AH
    J Prosthet Dent; 1988 Sep; 60(3):267-70. PubMed ID: 3050044
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reversible hydrocolloid impression techniques.
    Brady WF
    CDA J; 1985 Aug; 13(8):40-7. PubMed ID: 3896526
    [No Abstract]   [Full Text] [Related]  

  • 8. [Comparison of castings obtained using 2 impression materials. Van-R reversible hydrocolloid and vinyl polysiloxane 3M Express].
    Zemella A
    Dent Cadmos; 1986 Nov; 54(17):81-8. PubMed ID: 3556232
    [No Abstract]   [Full Text] [Related]  

  • 9. Simplified techniques for the preparation and use of reversible hydrocolloid impression material.
    Campagni WV; Rivera S; Davidoff SR
    J Prosthet Dent; 1985 Aug; 54(2):167-9. PubMed ID: 3903108
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The impression with reversible hydrocolloid--following the prescription and modified].
    Bauer A
    Dtsch Zahnarztl Z; 1971 Sep; 26(9):925-31. PubMed ID: 4936808
    [No Abstract]   [Full Text] [Related]  

  • 11. Clinical evaluation of reversible/irreversible hydrocolloid impression systems.
    Kelsey WP; Blankenau RJ; Cavel WT; Barkmeier WW
    Gen Dent; 1988; 36(6):506-7. PubMed ID: 3078308
    [No Abstract]   [Full Text] [Related]  

  • 12. The effect of storage time on the accuracy and dimensional stability of reversible hydrocolloid impression material.
    Schleier PE; Gardner FM; Nelson SK; Pashley DH
    J Prosthet Dent; 2001 Sep; 86(3):244-50. PubMed ID: 11552162
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The combined reversible hydrocolloid/irreversible hydrocolloid impression system: clinical application.
    Appleby DC; Cohen SR; Racowsky LP; Mingledorff EB
    J Prosthet Dent; 1981 Jul; 46(1):48-58. PubMed ID: 7024517
    [No Abstract]   [Full Text] [Related]  

  • 14. Evaluation of reversible hydrocolloid impression material in a wet field.
    Stewart GP; Bagley RL; Froemling RA
    J Prosthet Dent; 1984 Jun; 51(6):797-800. PubMed ID: 6376782
    [No Abstract]   [Full Text] [Related]  

  • 15. A method for using reversible hydrocolloid at high altitudes.
    Fine TD; Ito RJ; Christensen GJ; Cunningham PR
    J Prosthet Dent; 1977 Sep; 38(3):294-300. PubMed ID: 333100
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Combined reversible/irreversible hydrocolloid impression systems: comparative analysis.
    Appleby DC; Smith W; Lontz JF; Mingledorff EB
    J Prosthet Dent; 1985 Nov; 54(5):627-32. PubMed ID: 3903131
    [No Abstract]   [Full Text] [Related]  

  • 17. Custom-made water-cooled trays for reversible hydrocolloid impressions in difficult situations.
    Parel SM; Matalon V
    J Prosthet Dent; 1974 Jan; 31(1):91-4. PubMed ID: 4587625
    [No Abstract]   [Full Text] [Related]  

  • 18. [Accuracy of post impression in various directions. Combined reversible/irreversible hydrocolloid impression].
    Warita K
    Nihon Hotetsu Shika Gakkai Zasshi; 1987 Aug; 31(4):997-1010. PubMed ID: 3333583
    [No Abstract]   [Full Text] [Related]  

  • 19. [Impressions with combined reversible hydrocolloid-alginate (hydroalginate)].
    Verdino JB; Martini LF
    Chir Dent Fr; 1987 Oct; 57(398):31-5. PubMed ID: 3329599
    [No Abstract]   [Full Text] [Related]  

  • 20. [Reproduction of the spacing of bridge abutments by reversible hydrocolloid].
    Lehmann KM; Behrend G
    Dtsch Zahnarztl Z; 1984 Nov; 39(11):876-9. PubMed ID: 6397353
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.