225 related articles for article (PubMed ID: 495479)
1. Analysis of ethylene oxide--worker exposure.
Romano SJ; Renner JA
Am Ind Hyg Assoc J; 1979 Aug; 40(8):742-5. PubMed ID: 495479
[TBL] [Abstract][Full Text] [Related]
2. A new method for monitoring personal exposure to ethylene oxide in the occupational environment.
Qazi AH; Ketcham NH
Am Ind Hyg Assoc J; 1977 Nov; 38(11):635-47. PubMed ID: 930812
[TBL] [Abstract][Full Text] [Related]
3. Development and validation of a protocol for field validation of passive dosimeters for ethylene oxide excursion limit monitoring.
Puskar MA; Szopinski FG; Hecker LH
Am Ind Hyg Assoc J; 1991 Apr; 52(4):145-50. PubMed ID: 2069121
[TBL] [Abstract][Full Text] [Related]
4. Sub-part-per-million diffusional sampling for ethylene oxide with the 3M #3550 ethylene oxide monitor.
Mullins HE
Am Ind Hyg Assoc J; 1985 Oct; 46(10):625-31. PubMed ID: 4061293
[TBL] [Abstract][Full Text] [Related]
5. Laboratory validation and field verification of a new passive air monitoring badge for sampling ethylene oxide in air.
Kring EV; Damrell DJ; Basilio AN; McGibney PD; Douglas JJ; Henry TJ; Ansul GR
Am Ind Hyg Assoc J; 1984 Oct; 45(10):697-707. PubMed ID: 6496316
[TBL] [Abstract][Full Text] [Related]
6. Laboratory validation of five commercially available methods for sampling ethylene oxide in air.
Kring EV; McGibney PD; Thornley GD
Am Ind Hyg Assoc J; 1985 Oct; 46(10):620-4. PubMed ID: 4061292
[TBL] [Abstract][Full Text] [Related]
7. The development and evaluation of a hydrobromic acid-coated sampling tube for measuring occupational exposures to ethylene oxide.
Cummins KJ; Schultz GR; Lee JS; Nelson JH; Reading JC
Am Ind Hyg Assoc J; 1987 Jun; 48(6):563-73. PubMed ID: 3039819
[TBL] [Abstract][Full Text] [Related]
8. Personal exposure level and environmental ethylene oxide gas concentration in sterilization facilities of hospitals in Japan.
Hori H; Yahata K; Fujishiro K; Yoshizumi K; Li D; Goto Y; Higashi T
Appl Occup Environ Hyg; 2002 Sep; 17(9):634-9. PubMed ID: 12216593
[TBL] [Abstract][Full Text] [Related]
9. How to test for ethylene oxide concentration.
Marino DJ
Hosp Purch Manage; 1980 Jan; 5(1):10-1. PubMed ID: 10244912
[No Abstract] [Full Text] [Related]
10. [Development of the method for determining substances--markers of the hazardous production of advanced oil processing (ethylene oxide, 1,3-butadiene) in the air at the level of reference concentrations].
Gig Sanit; 2012; (4):78-82. PubMed ID: 23082678
[TBL] [Abstract][Full Text] [Related]
11. Laboratory evaluation of stain-length passive dosimeters for monitoring of vinyl chloride and ethylene oxide.
Gonzalez LA; Sefton MV
Am Ind Hyg Assoc J; 1985 Oct; 46(10):591-8. PubMed ID: 4061289
[TBL] [Abstract][Full Text] [Related]
12. [The level of ethylene oxide in air].
Bossiroy JM; Roosels D
Arch Belg; 1983; 41(5-6):241-8. PubMed ID: 6670887
[No Abstract] [Full Text] [Related]
13. [Gas chromatographic determination of ethylene oxide in the air].
Dmitriev MT; Mishchikhin VA
Gig Sanit; 1982 Apr; (4):65-8. PubMed ID: 7115493
[No Abstract] [Full Text] [Related]
14. [Gas chromatographic determination of ethylene oxide in atmospheric air].
Kuznetsova LV
Gig Sanit; 1984 Oct; (10):52-3. PubMed ID: 6519457
[No Abstract] [Full Text] [Related]
15. Ethylene oxide environmental monitoring in a health care facility.
Reichert MC
Med Instrum; 1983; 17(2):113-5. PubMed ID: 6406802
[TBL] [Abstract][Full Text] [Related]
16. Field validation of three passive dosimeters for excursion limit monitoring of ethylene oxide.
Szopinski FG; Puskar MA; Hecker LH
Am Ind Hyg Assoc J; 1991 Apr; 52(4):151-6; discussion 156-7. PubMed ID: 2069122
[TBL] [Abstract][Full Text] [Related]
17. Thermal desorption-capillary gas chromatography for the quantitative analysis of dimethyl sulphate, diethyl sulphate and ethylene oxide in the workplace.
Düblin T; Thöne HJ
J Chromatogr; 1988 Dec; 456(1):233-9. PubMed ID: 3243868
[TBL] [Abstract][Full Text] [Related]
18. Biomonitoring of industrial styrene exposures.
Fields RL; Horstman SW
Am Ind Hyg Assoc J; 1979 Jun; 40(6):451-9. PubMed ID: 484461
[TBL] [Abstract][Full Text] [Related]
19. A simple method for the measurement of carbonyl sulfide in the presence of hydrogen sulphide.
Confer RG; Brief RS
Am Ind Hyg Assoc J; 1975 Nov; 36(11):843-4. PubMed ID: 1211349
[No Abstract] [Full Text] [Related]
20. Laboratory and field validation of a JXC charcoal sampling and analytical method for monitoring short-term exposures to ethylene oxide.
Puskar MA; Nowak JL; Hecker LH
Am Ind Hyg Assoc J; 1988 May; 49(5):237-43. PubMed ID: 3400587
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]