These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 496502)

  • 61. A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices†.
    Ng CS; Pickens A; Siegel JM; Clymer JW; Cummings JF
    Eur J Cardiothorac Surg; 2016 Jan; 49 Suppl 1(Suppl 1):i73-8. PubMed ID: 26464450
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Development of the surgical stapling device.
    Robicsek F
    Thorac Cardiovasc Surg; 1993 Aug; 41(4):207-15. PubMed ID: 8211924
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Robotic Lobectomy Utilizing the Robotic Stapler.
    Pearlstein DP
    Ann Thorac Surg; 2016 Dec; 102(6):e591-e593. PubMed ID: 27847093
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Hepatic resection using stapling devices.
    Kaneko H; Otsuka Y; Takagi S; Tsuchiya M; Tamura A; Shiba T
    Am J Surg; 2004 Feb; 187(2):280-4. PubMed ID: 14769320
    [TBL] [Abstract][Full Text] [Related]  

  • 65. [Comparative study of the healing of bronchial stumps after pulmonary excision in dogs: manual suturing opposed to mechanical stapling].
    Gamondès JP; Eloi R; Adeleine P; Tabib A; Loire R
    Ann Chir; 1984 Mar; 38(2):188-92. PubMed ID: 6375534
    [No Abstract]   [Full Text] [Related]  

  • 66. Tailoring of the lung to overcome size disparities in lung transplantation.
    Wisser W; Klepetko W; Wekerle T; Laufer G; Stift A; Hiesmayr M; Schlick W
    J Heart Lung Transplant; 1996 Mar; 15(3):239-42. PubMed ID: 8777205
    [TBL] [Abstract][Full Text] [Related]  

  • 67. A new technological approach to nonanatomical pulmonary resection: saline enhanced thermal sealing.
    Yim AP; Rendina EA; Hazelrigg SR; Chow LT; Lee TW; Wan S; Arifi AA
    Ann Thorac Surg; 2002 Nov; 74(5):1671-6. PubMed ID: 12440628
    [TBL] [Abstract][Full Text] [Related]  

  • 68. [Thoracoscopic lobectomy in the animal model].
    Inderbitzi R; Furrer M; Striffeler H; Altermatt HJ; Althaus U
    Chirurg; 1993 Apr; 64(4):324-8; discussion 328. PubMed ID: 8482151
    [TBL] [Abstract][Full Text] [Related]  

  • 69. [Staplers and pulmonary surgery].
    Paolini A; Ruggieri M; Caminiti A; Paolini G; Paoletti M; Lepore M
    G Chir; 1992 Apr; 13(4):198-9. PubMed ID: 1637629
    [TBL] [Abstract][Full Text] [Related]  

  • 70. [Video thoracoscopic lobectomy. Surgical technique and results].
    Stamatis G; Fechner S
    Chirurg; 1996 Apr; 67(4):425-35. PubMed ID: 8646932
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Robotic pulmonary resections in children: series report and introduction of a new robotic instrument.
    Meehan JJ; Phearman L; Sandler A
    J Laparoendosc Adv Surg Tech A; 2008 Apr; 18(2):293-5. PubMed ID: 18373461
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Experimental study of the effects of different stapling devices in healing of the mechanically sutured bronchial stump.
    Dziedzic D; Orlowski TM; Jakimiuk R
    Eur J Cardiothorac Surg; 2000 Feb; 17(2):111-6. PubMed ID: 10731645
    [TBL] [Abstract][Full Text] [Related]  

  • 73. [Structural evaluation of the remaining lung after partial pulmonary resection by the stapling device].
    Murakami J; Ueda K; Sano F; Hayashi M; Hamano K
    Kyobu Geka; 2014 Sep; 67(10):867-72. PubMed ID: 25201360
    [TBL] [Abstract][Full Text] [Related]  

  • 74. The advantages of selecting cartridges with a 1.8 mm height for pulmonary stapling.
    Yano M; Yamada T; Uchida T; Moriyama S; Haneda H; Okuda K; Nakanishi R
    Surg Today; 2016 Oct; 46(10):1176-80. PubMed ID: 26679710
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Penrose drain tube as a guide for endostaplers during lobectomy via video-assisted thoracoscopic surgery.
    Lin MW; Lee JM; Lee YC
    Thorac Cardiovasc Surg; 2010 Apr; 58(3):184-5. PubMed ID: 20376733
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Asymptomatic expectoration of surgical staples complicating lung volume reduction surgery.
    Ahmed S; Marzouk KA; Bhuiya TA; Iqbal M; Rossoff LJ
    Chest; 2001 Jan; 119(1):307-8. PubMed ID: 11157625
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Complications associated with the use of gastrointestinal stapling devices.
    Wassner JD; Yohai E; Heimlich HJ
    Surgery; 1977 Sep; 82(3):395-9. PubMed ID: 888105
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Comparing bipolar electrothermal device and endostapler in endoscopic lung wedge resection.
    Kovács O; Szántó Z; Krasznai G; Herr G
    Interact Cardiovasc Thorac Surg; 2009 Jul; 9(1):11-4. PubMed ID: 19342390
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Use of a simultaneous ligating-dividing-stapling instrument for ovariohysterectomy.
    Hess JL
    Vet Med Small Anim Clin; 1979 Oct; 74(10):1480-5. PubMed ID: 261005
    [No Abstract]   [Full Text] [Related]  

  • 80. [Surgical staplers in lung surgery].
    Solaini L; Ribichini P; Bagioni P
    G Chir; 1991 Mar; 12(3):220. PubMed ID: 1873180
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.